AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Niitsu, M.
Right arrow Articles by Itai, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Niitsu, M.
Right arrow Articles by Itai, Y.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 168, 651-655, Copyright © 1997 by American Roentgen Ray Society


ARTICLES

Multishot echoplanar MR imaging of the female pelvis: comparison with fast spin-echo MR imaging in an initial clinical trial

M Niitsu, YO Tanaka, I Anno and Y Itai
Department of Radiology, University of Tsukuba, Ibaraki, Japan.

OBJECTIVE: The purpose of this study was to apply multishot echoplanar MR imaging (EPI) to the female pelvis and compare image quality with that of fast spin-echo MR imaging. SUBJECTS AND METHODS: Twenty-one patients with suspected pelvic disease and five healthy female volunteers were prospectively examined. MR imaging was obtained using an EPI-capable 1.0-T imager and a pelvic phased-array coil. Axial EPI and fast Spin-echo sequences were obtained at identical image locations in each patient and volunteer. Spin-echo EPI images were obtained using a multishot number of 16. Acquisition time for each EPI sequence was 2 min 10 sec. Fat-suppressed T2-weighted fast spin-echo images were obtained in 2 min 12 sec. Paired EPI and fast spin-echo MR images were independently evaluated by three reviewers. RESULTS: Delineation of the perivaginal and parametrial venous plexus on EPI was rated superior to the fast spin-echo images in 62 (77%) of 81 cases. On EPI, uterine zone anatomy and ovary visualization were judged to be inferior in 44 (56%) of 78 cases and in 18 (33%) of 54 cases, respectively. For delineation of uterine abnormalities, including leiomyoma and adenomyosis, both sequences performed almost equally well. However, ovarian cystic lesions were revealed more precisely by the fast spin-echo sequence. An overall fat-suppression effect was seen on EPI images in 62 (77%) of 81 cases. CONCLUSION: Multishot EPI cannot replace fast spin-echo sequences for imaging the female pelvis; however, because EPI has a potent fat-suppression effect and heavily T2-weighted contrast, EPI sequences can be a valuable adjunct to routine examination.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. Katayama, T. Masui, S. Kobayashi, T. Ito, H. Sakahara, A. Nozaki, and H. Kabasawa
Evaluation of Pelvic Adhesions Using Multiphase and Multislice MR Imaging with Kinematic Display
Am. J. Roentgenol., July 1, 2001; 177(1): 107 - 110.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Roentgen Ray Society.