|
|
||||||||
American Journal of Roentgenology, Vol 168, 713-717, Copyright © 1997 by American Roentgen Ray Society
ARTICLES |
BE Van Beers, M Lacrosse, J Jamart, C Grandin, JF Gigot, Y Horsmans, R Demeure and J Pringot
Department of Radiology, St-Luc University Hospital, Universite Catholique de Louvain, Brussels, Belgium.
OBJECTIVE: The aim of our prospective study was to compare the values of ferumoxides-enhanced gradient-echo and T2-weighted spin-echo MR imaging for the detection and segmental location of malignant hepatic tumors. SUBJECTS AND METHODS: Eighteen patients underwent ferumoxides- enhanced T2 weighted spin-echo and steady-state gradient-echo imaging before surgery. Intraoperative sonography was used as the reference examination and showed 28 malignant tumors involving 39 of the 144 hepatic segments. The MR images were reviewed independently by two observers who recorded the number of tumors and their segmental location. The results of the segmental location were subjected to receiver-operating-characteristic analysis. Tumor-liver, vessel-liver, and tumor-vessel contrast-to-noise ratios were calculated. RESULTS: Detection on the gradient-echo images did not differ significantly from that on the T2-weighted spin-echo MR images (observers A and B detected 23 and 24 tumors, respectively, on the gradient-echo images; the two observers each detected 22 tumors on the T2-weighted spin-echo images). Segmental localization was significantly better on the gradient-echo images than on the T2-weighted spin-echo images (mean area under the receiver-operating-characteristic curve: 0.974 versus 0.895 for observer A and 0.962 versus 0.906 for observer B, p = .024). The highest contrast-to-noise ratios for vessel to liver and tumor to vessel were obtained on the gradient-echo images and the highest tumor- liver contrast-to-noise ratio was obtained on the T2-weighted spin-echo images. CONCLUSION: In our study, ferumoxides-enhanced gradient-echo imaging was as accurate as T2-weighted spin-echo imaging for revealing malignant hepatic tumors and was superior for showing their segmental location.
This article has been cited by other articles:
![]() |
M.-J. Kim, J. H. Kim, J. Y. Choi, S. H. Park, J.-J. Chung, K. W. Kim, and D. G. Mitchell Optimal TE for SPIO-enhanced gradient-recalled echo MRI for the detection of focal hepatic lesions. Am. J. Roentgenol., September 1, 2006; 187(3): W255 - W266. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, P. J. Robinson, J. A. Guthrie, S. Downing, D. Wilson, J. P. A. Lodge, K. R. Prasad, G. J. Toogood, and J. I. Wyatt Liver Metastases in Candidates for Hepatic Resection: Comparison of Helical CT and Gadolinium- and SPIO-enhanced MR Imaging Radiology, October 1, 2005; 237(1): 170 - 180. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Matsuo, M. Kanematsu, K. Itoh, T. Murakami, Y. Maetani, H. Kondo, S. Goshima, N. Kako, H. Hoshi, J. Konishi, et al. Detection of Malignant Hepatic Tumors with Ferumoxides-Enhanced MRI: Comparison of Five Gradient-Recalled Echo Sequences with Different TEs Am. J. Roentgenol., January 1, 2004; 182(1): 235 - 242. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, J. A. Guthrie, D. Wilson, P. Arnold, J. P. Lodge, G. J. Toogood, J. I. Wyatt, and P. J. Robinson Colorectal Hepatic Metastases: Detection with SPIO-enhanced Breath-hold MR Imaging—Comparison of Optimized Sequences Radiology, September 1, 2003; 228(3): 709 - 718. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Kim, S. H. Kim, W. J. Lee, H. Kim, J. W. Seo, D. Choi, H. K. Lim, S. J. Lee, and J. H. Lim Preoperative Detection of Hepatocellular Carcinoma: Ferumoxides-Enhanced Versus Mangafodipir Trisodium--Enhanced MR Imaging Am. J. Roentgenol., September 1, 2002; 179(3): 741 - 750. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. Raman, D. S. K. Lu, S. C. Chen, J. Sayre, F. Eilber, and J. Economou Hepatic MR Imaging Using Ferumoxides: Prospective Evaluation with Surgical and Intraoperative Sonographic Confirmation in 25 Cases Am. J. Roentgenol., October 1, 2001; 177(4): 807 - 812. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. Bluemke, E. K. Paulson, M. A. Choti, S. DeSena, and P. A. Clavien Detection of Hepatic Lesions in Candidates for Surgery: Comparison of Ferumoxides-Enhanced MR Imaging and Dual-Phase Helical CT Am. J. Roentgenol., December 1, 2000; 175(6): 1653 - 1658. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Ward, F. Chen, J. A. Guthrie, D. Wilson, J. P. A. Lodge, J. I. Wyatt, and P. J. Robinson Hepatic Lesion Detection after Superparamagnetic Iron Oxide Enhancement: Comparison of Five T2-weighted Sequences at 1.0 T by Using Alternative-Free Response Receiver Operating Characteristic Analysis1 Radiology, January 1, 2000; 214(1): 159 - 166. [Abstract] [Full Text] |
||||
![]() |
J. Ward, K. S. Naik, J. A. Guthrie, D. Wilson, and P. J. Robinson Hepatic Lesion Detection: Comparison of MR Imaging after the Administration of Superparamagnetic Iron Oxide with Dual-Phase CT by Using Alternative–Free Response Receiver Operating Characteristic Analysis Radiology, February 1, 1999; 210(2): 459 - 466. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |