American Journal of Roentgenology, Vol 168, 1199-1204, Copyright © 1997 by American Roentgen Ray Society
ARTICLES |
P Soyer, M Gouhiri, Y Rondeau, L Spelle, H Mosnier and A Scherrer
Department of Radiology, Hopital Foch, Suresnes, France.
OBJECTIVE: Our objective was to compare the sensitivity of non-breath- hold T2-weighted fast spin-echo with and without fat suppression, breath-hold T2-weighted fast spin-echo without fat suppression, and spoiled gradient-recalled echo (GRE) MR imaging for detecting hepatic tumors using surgical findings as the standard of reference. SUBJECTS AND METHODS: Eighteen patients with 36 surgically proven hepatic tumors had non-breath-hold T2-weighted fast spin-echo (6000/117 [TR/effective TE; echo train length, 16) MR imaging with and without fat suppression, breath-hold T2-weighted fast spin-echo MR imaging (2700/105; echo train length, 20), and spoiled GRE images (10.1/1.9; flip angle, 30 degrees) obtained before and after injection of a gadolinium chelate. Images were analyzed separately by two independent readers, with disagreements resolved by consensus reading. RESULTS: Non-breath-hold T2-weighted fast spin-echo MR imaging with and without fat suppression depicted 22 (61%; 95% confidence interval [CI], 43-77%) and 20 (56%; 95% CI, 37- 72%) of 36 hepatic tumors, respectively. Breath-hold T2-weighted fast spin-echo imaging allowed detection of 19 (53%; 95% CI, 35-69%) of 36 hepatic tumors. Unenhanced and gadolinium chelate-enhanced spoiled GRE images allowed depiction of 18 (50%; 95% CI, 33-67%) and 29 (81%; 95% CI, 63-91%) of 36 hepatic tumors, respectively. Gadolinium chelate- enhanced spoiled GRE images allowed depiction of significantly more hepatic tumors than any of the other pulse sequences. CONCLUSION: Gadolinium chelate-enhanced spoiled GRE imaging is more sensitive than T2-weighted MR imaging obtained with a breath-hold or a non-breath-hold technique.
This article has been cited by other articles:
![]() |
T. Parikh, S. J. Drew, V. S. Lee, S. Wong, E. M. Hecht, J. S. Babb, and B. Taouli Focal Liver Lesion Detection and Characterization with Diffusion-weighted MR Imaging: Comparison with Standard Breath-hold T2-weighted Imaging Radiology, March 1, 2008; 246(3): 812 - 822. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Hecht, A. E. Holland, G. M. Israel, W. Y. Hahn, D. C. Kim, A. B. West, J. S. Babb, B. Taouli, V. S. Lee, and G. A. Krinsky Hepatocellular Carcinoma in the Cirrhotic Liver: Gadolinium-enhanced 3D T1-weighted MR Imaging as a Stand-alone Sequence for Diagnosis. Radiology, May 1, 2006; 239(2): 438 - 447. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Dromain, T. de Baere, E. Baudin, J. Galline, M. Ducreux, V. Boige, P. Duvillard, A. Laplanche, H. Caillet, P. Lasser, et al. MR Imaging of Hepatic Metastases Caused by Neuroendocrine Tumors: Comparing Four Techniques Am. J. Roentgenol., January 1, 2003; 180(1): 121 - 128. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. S. Fulcher, R. A. Szucs, M. J. Bassignani, and A. Marcos Right Lobe Living Donor Liver Transplantation: Preoperative Evaluation of the Donor with MR Imaging Am. J. Roentgenol., June 1, 2001; 176(6): 1483 - 1491. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Valls, E. Andía, A. Sánchez, A. Gumà, J. Figueras, J. Torras, and T. Serrano Hepatic Metastases from Colorectal Cancer: Preoperative Detection and Assessment of Resectability with Helical CT Radiology, January 1, 2001; 218(1): 55 - 60. [Abstract] [Full Text] |
||||