AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kallmes, D. F.
Right arrow Articles by Phillips, C. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kallmes, D. F.
Right arrow Articles by Phillips, C. D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 168, 1317-1319, Copyright © 1997 by American Roentgen Ray Society


ARTICLES

The normal anterior commissure of the glottis

DF Kallmes and CD Phillips
Department of Radiology, University of Virginia Health Sciences Center, Charlottesville 22908, USA.

OBJECTIVE: We characterized the normal width of the anterior commissure of the glottis by measuring its dimensions on CT scans obtained in patients who had no laryngeal disorders. SUBJECTS AND METHODS: CT scans of patients referred for cervical CT myelography were prospectively reviewed by a single board-certified radiologist. Axial images through the anterior commissure (localized by vocal process of the arytenoid cartilage, the vocal muscle, or both) were magnified on the viewing console of the CT scanner. Window and level were chosen to simulate our routine settings for CT scans of the neck. Anteroposterior width of the anterior commissure was measured using an electronic ruler with 1-mm marks. RESULTS: Sixty-five patients were prospectively evaluated. Nine patients were excluded because of substantial motion artifact, and another 18 were excluded because CT images did not include the entire larynx. Thus, the final study group included 38 patients. The average width of the anterior commissure was 1.02 +/- 0.56 mm. The width was less than or equal to 1.1 mm in 22 (58%) of 38 patients. The width was less than or equal to 1.7 mm in 35 (92%) of 38 patients. Forty-two percent (16 of 38 patients) had anterior commissures wider than 1.0 mm. The maximum width of 2.2 mm was seen in only one patient. CONCLUSION: The mean width of the anterior commissure was approximately 1.0 mm. However, 42% of patients had anterior commissures wider than 1.0 mm. In our series, using an upper limit of 1.6 mm as a normal measurement for the anterior commissure would have included 92% of patients, and an upper limit of 2.1 mm would have encompassed the mean plus two SDs.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Roentgen Ray Society.