|
|
||||||||
American Journal of Roentgenology, Vol 169, 661-666, Copyright © 1997 by American Roentgen Ray Society
ARTICLES |
PM Boiselle, JA Shepard, EJ Mark, WM Szyfelbein, CM Fan, PJ Slanetz, B Trotman- Dickenson, EF Halpern, SW Miller and TC McLoud
Department of Radiology, Massachusetts General Hospital, Boston 02114, USA.
OBJECTIVE: The purpose of this study was to prospectively assess the usefulness of the routine addition of an automated biopsy device (ABD) to fine-needle aspiration (FNA) of the lung and to examine the complication rate of this procedure. SUBJECTS AND METHODS: Fifty biopsies were performed under CT guidance using a coaxial technique with a 19-gauge introducer needle and a 22-gauge aspirating needle followed by a 20-gauge ABD. An average of 3.5 FNA specimens and 2.5 core specimens were obtained. Cytology and histology specimens were interpreted separately by two experienced pathologists who were unaware of the other's interpretation. Final diagnoses were based on surgery, microbiology, definitive biopsy diagnosis, and clinical follow-up. All complications were recorded. RESULTS: Of 34 malignant lesions, we achieved a diagnostic accuracy of 94% for FNA and 59% for core biopsy (p < .01). Combined accuracy was 94%. Of 16 benign lesions, an accurate definitive diagnosis was made in 31% of cases using FNA and in 69% of cases using core biopsy (p = .08). Combined accuracy was 69%. In the subset of benign lesions that were not acute infections (n = 8), an accurate definitive benign diagnosis was made in 12% of cases using FNA and in 75% of cases using core biopsy (p < .05). No false-positive diagnoses of malignancy occurred. Complications included pneumothorax, nine (18%) of 50 cases; chest tube, one (2%) of 50 cases minor pulmonary hemorrhage, seven (14%) of 50 cases; and minor hemoptysis, two (4%) of 50 cases. CONCLUSION: The complication rates of FNA with the addition of an ABD are similar to those reported in the literature for FNA alone. The addition of an ABD significantly increases the diagnostic accuracy only for the subset of benign lesions that are not acute infections.
This article has been cited by other articles:
![]() |
R YOSHIMATSU, T YAMAGAMI, T KATO, T HIROTA, T MATSUMOTO, J SHIMADA, and T NISHIMURA Percutaneous needle biopsy of lung nodules under CT fluoroscopic guidance with use of the "I-I device" Br. J. Radiol., February 1, 2008; 81(962): 107 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A. Meyer "Transthoracic Needle Aspiration Biopsy of Benign and Malignant Lung Lesions"--A Commentary Am. J. Roentgenol., April 1, 2007; 188(4): 891 - 893. [Full Text] [PDF] |
||||
![]() |
H. T. Winer-Muram The solitary pulmonary nodule. Radiology, April 1, 2006; 239(1): 34 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Matsuguma, R. Nakahara, T. Kondo, Y. Kamiyama, K. Mori, and K. Yokoi Risk of Pleural Recurrence After Needle Biopsy in Patients With Resected Early Stage Lung Cancer Ann. Thorac. Surg., December 1, 2005; 80(6): 2026 - 2031. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. M. Maher, M. K. Kalra, R. L. Titton, G. W. Boland, C. Wittram, S. Aquino, P. R. Mueller, and J.-A. O. Shepard Percutaneous Lung Biopsy in a Patient with a Cavitating Lung Mass: Indications, Technique, and Complications Am. J. Roentgenol., October 1, 2005; 185(4): 989 - 994. [Full Text] [PDF] |
||||
![]() |
D R Baldwin, J D Birchall, R H Ganatra, and K S Pointon Evaluation of the solitary pulmonary nodule: clinical management, role of CT and nuclear medicine Imaging, October 1, 2004; 16(1): 22 - 36. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, T. Kato, S. Iida, T. Hirota, and T. Nishimura Percutaneous Needle Biopsy for Small Lung Nodules Beneath the Rib Under CT Scan Fluoroscopic Guidance With Gantry Tilt Chest, September 1, 2004; 126(3): 744 - 747. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. I. Jandzinski, N. Carson, D. Davis, D. J. Rubens, S. L. Voci, and R. H. Gottlieb Treated Needles: Do They Facilitate Sonographically Guided Biopsies? J. Ultrasound Med., November 1, 2003; 22(11): 1233 - 1237. [Abstract] [Full Text] [PDF] |
||||
![]() |
A Manhire, M Charig, C Clelland, F Gleeson, R Miller, H Moss, K Pointon, C Richardson, and E Sawicka Guidelines for radiologically guided lung biopsy Thorax, November 1, 2003; 58(11): 920 - 936. [Full Text] [PDF] |
||||
![]() |
T. Yamagami, S. Iida, T. Kato, O. Tanaka, S. Toda, D. Kato, and T. Nishimura Usefulness of New Automated Cutting Needle for Tissue-Core Biopsy of Lung Nodules Under CT Fluoroscopic Guidance Chest, July 1, 2003; 124(1): 147 - 154. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, S. Iida, T. Kato, O. Tanaka, and T. Nishimura Combining Fine-Needle Aspiration and Core Biopsy Under CT Fluoroscopy Guidance: A Better Way to Treat Patients with Lung Nodules? Am. J. Roentgenol., March 1, 2003; 180(3): 811 - 815. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. B. Tan, K. R. Flaherty, E. A. Kazerooni, and M. D. Iannettoni The Solitary Pulmonary Nodule Chest, January 1, 2003; 123(1_suppl): 89S - 96S. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, T. Nakamura, S. Iida, T. Kato, and T. Nishimura Management of Pneumothorax After Percutaneous CT-Guided Lung Biopsy* Chest, April 1, 2002; 121(4): 1159 - 1164. [Abstract] [Full Text] [PDF] |
||||
![]() |
S M Williams, W Gray, and F V Gleeson Macroscopic assessment of pulmonary fine needle aspiration biopsies: correlation with cytological diagnostic yield Br. J. Radiol., January 1, 2002; 75(889): 28 - 30. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Ghaye and R.F. Dondelinger Imaging guided thoracic interventions Eur. Respir. J., March 1, 2001; 17(3): 507 - 528. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Rozenblit, J. Tuvia, G. N. Rozenblit, and A. Klink CT-Guided Transthoracic Needle Biopsy Using an Ipsilateral Dependent Position Am. J. Roentgenol., June 1, 2000; 174(6): 1759 - 1764. [Abstract] [Full Text] |
||||
![]() |
K. Shaffer Role of Radiology for Imaging and Biopsy of Solitary Pulmonary Nodules* Chest, December 1, 1999; 116(suppl_3): 519S - 522S. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Lacasse, E. Wong, G. H Guyatt, and D. J Cook Transthoracic needle aspiration biopsy for the diagnosis of localised pulmonary lesions: a meta-analysis Thorax, October 1, 1999; 54(10): 884 - 893. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |