AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Muller-Hulsbeck, S.
Right arrow Articles by Heller, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Muller-Hulsbeck, S.
Right arrow Articles by Heller, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 169, 743-748, Copyright © 1997 by American Roentgen Ray Society


ARTICLES

MR imaging signal-intensity abnormalities after placement of arterial endoprostheses

S Muller-Hulsbeck, J Link, H Schwarzenberg, JC Steffens, J Brossmann, A Hulsbeck and M Heller
Department of Radiology, University Hospital, Kiel, Germany.

OBJECTIVE: Our objectives were to describe changes in T2-weighted MR images of patients who had undergone implantation of an endoluminal stent-graft and determine the rate of early reocclusion in patients with abnormal MR findings. SUBJECTS AND METHODS: Twenty-nine patients with 26 occlusions (average length, 8.7 +/- 5.6 cm) and three dissections of the superficial femoral artery were treated with 45 endoluminal stent-grafts. T2-weighted gradient-echo and T2-weighted turbo spin-echo MR images were obtained for all patients at 48 hr and at 4 weeks after stent-graft placement. We reviewed the MR imaging studies to assess the extent and severity of tissue alteration at the site of stent-graft implantation. RESULTS: Technical success rate of stent-graft placement was 100%. Three signal-intensity patterns were seen on MR images obtained at 48 hr: normal signal intensity (n = 8), subtle perivascular signal-intensity abnormalities at the site of stent- graft implantation (n = 11), and extensive signal-intensity abnormalities from the adductor canal to the subcutis (n = 10). Twenty of 21 patients with abnormal signal intensity on MR images had fevers and pain at the implantation site. Clinical signs of deep vein thrombosis, a diagnosis excluded on the basis of phlebography, were seen in the 10 patients with extensive signal-intensity abnormalities. In two of these 10 patients, the superficial femoral artery reoccluded within 4 weeks of implantation. MR images obtained at 4 weeks showed no signal-intensity abnormalities in any of the 29 patients. CONCLUSION: MR findings of perivascular signal-intensity abnormalities after implantation of endoluminal stent-grafts are associated with clinical complications such as local pain and fever. Care should be taken to avoid confusing the clinical signs of the postimplantation syndrome at 48 hr with deep vein thrombosis.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. U. Juergens, B. Tombach, P. Reimer, T. Vestring, and W. Heindel
Three-Dimensional Contrast-Enhanced MR Angiography of Endovascular Covered Stents in Patients with Peripheral Arterial Occlusive Disease
Am. J. Roentgenol., May 1, 2001; 176(5): 1299 - 1303.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1997 by the American Roentgen Ray Society.