American Journal of Roentgenology, Vol 169, 859-862, Copyright © 1997 by American Roentgen Ray Society
ARTICLES |
ER Melhem, H Jara and S Eustace
Department of Radiology, Boston University School of Medicine, Boston Medical Center, MA 02118, USA.
OBJECTIVE: Using human volunteers and phantoms emulating CSF, we analyzed the effects of varying protein concentration on the signal intensity of saline solution. Also, for different fluid-attenuated inversion recovery (FLAIR) sequences, we compared protein concentration thresholds above which the signal from these solutions becomes hyperintense to that from brain parenchyma. SUBJECTS AND METHODS: Nine albumin solutions of varying concentrations (3.9 mg/dl to 2500 mg/dl) were imaged using fast FLAIR MR sequences (TR, 6000 msec: inversion time, 1730 msec: echo train length, 20) at different effective TEs (110, 150, 200, and 250 signal-to-noise ratios from the different albumin solutions versus albumin concentration were generated and correlated with average signal-to-noise ratios from brain parenchyma and CSF. RESULTS: We saw a gradual increase in signal-to-noise ratios from the albumin solutions as a function of albumin concentration. As the effective TE increased, the point of intersection between the plots and the average signal-to-noise ratio from brain parenchyma occurred at lower albumin concentrations. CONCLUSION: FLAIR MR imaging is potentially useful to evaluate pathologic conditions that increase CSF protein concentration. Using phantoms and healthy volunteers, we defined a protein concentration threshold above which the signal from saline solutions becomes hyperintense to that from brain parenchyma. This threshold depends on the effective TE used in the FLAIR sequence and is 250 mg/dl for an effective TE of 110 msec, 125 mg/dl for 150 msec. 110 mg/dl for 200 msec, and 95 mg/dl for 250 msec.
This article has been cited by other articles:
![]() |
P. S. Silk, J. I. Lane, and C. L. Driscoll Surgical Approaches to Vestibular Schwannomas: What the Radiologist Needs to Know RadioGraphics, November 1, 2009; 29(7): 1955 - 1970. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Weier, F. Fluri, S. Kos, and A. Gass POSTCONTRAST FLAIR MRI DEMONSTRATES BLOOD-BRAIN BARRIER DYSFUNCTION IN PRES Neurology, February 24, 2009; 72(8): 760 - 762. [Full Text] [PDF] |
||||
![]() |
M. Tosaka, N. Sato, H. Fujimaki, Y. Tanaka, K. Kagoshima, A. Takahashi, N. Saito, and Y. Yoshimoto Diffuse Pachymeningeal Hyperintensity and Subdural Effusion/Hematoma Detected by Fluid-Attenuated Inversion Recovery MR Imaging in Patients with Spontaneous Intracranial Hypotension AJNR Am. J. Neuroradiol., June 1, 2008; 29(6): 1164 - 1170. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.A. Bhadelia, K.L. Tedesco, S. Hwang, S.H. Erbay, P.H. Lee, W. Shao, and C. Heilman Increased Cochlear Fluid-Attenuated Inversion Recovery Signal in Patients with Vestibular Schwannoma AJNR Am. J. Neuroradiol., April 1, 2008; 29(4): 720 - 723. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.M. Morris and G.M. Miller Increased Signal in the Subarachnoid Space on Fluid-Attenuated Inversion Recovery Imaging Associated with the Clearance Dynamics of Gadolinium Chelate: A Potential Diagnostic Pitfall AJNR Am. J. Neuroradiol., November 1, 2007; 28(10): 1964 - 1967. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Cianfoni, M.G.M. Martin, J. Du, J.R. Hesselink, S.G. Imbesi, W.G. Bradley, and G.M. Bydder Artifact simulating subarachnoid and intraventricular hemorrhage on single-shot, fast spin-echo fluid-attenuated inversion recovery images caused by head movement: A trap for the unwary. AJNR Am. J. Neuroradiol., April 1, 2006; 27(4): 843 - 849. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Anzai, M. Ishikawa, D. W. W. Shaw, A. Artru, V. Yarnykh, and K. R. Maravilla Paramagnetic Effect of Supplemental Oxygen on CSF Hyperintensity on Fluid-Attenuated Inversion Recovery MR Images AJNR Am. J. Neuroradiol., February 1, 2004; 25(2): 274 - 279. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Frigon, D. S. Jardine, E. Weinberger, S. R. Heckbert, and D. W. W. Shaw Fraction of Inspired Oxygen in Relation to Cerebrospinal Fluid Hyperintensity on FLAIR MR Imaging of the Brain in Children and Young Adults Undergoing Anesthesia Am. J. Roentgenol., September 1, 2002; 179(3): 791 - 796. [Abstract] [Full Text] [PDF] |
||||
![]() |
H.-M. Wu, D. M. Yousem, H.-W. Chung, W.-Y. Guo, C.-Y. Chang, and C.-Y. Chen Influence of Imaging Parameters on High-Intensity Cerebrospinal Fluid Artifacts in Fast-FLAIR MR Imaging AJNR Am. J. Neuroradiol., March 1, 2002; 23(3): 393 - 399. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. T. Rai and J. P. Hogg Persistence of Gadolinium in CSF: A Diagnostic Pitfall in Patients with End-stage Renal Disease AJNR Am. J. Neuroradiol., August 1, 2001; 22(7): 1357 - 1361. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. L. Wolf Intraarterial Signal on Fluid-attenuated Inversion Recovery Images: A Measure of Hemodynamic Stress? AJNR Am. J. Neuroradiol., June 1, 2001; 22(6): 1015 - 1017. [Full Text] [PDF] |
||||
![]() |
C. G. Filippi, A. M. Ulug, D. Lin, L. A. Heier, and R. D. Zimmerman Hyperintense Signal Abnormality in Subarachnoid Spaces and Basal Cisterns on MR Images of Children Anesthetized with Propofol: New Fluid-attenuated Inversion Recovery Finding AJNR Am. J. Neuroradiol., February 1, 2001; 22(2): 394 - 399. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Taoka, W. T. C. Yuh, M. L. White, J. P. Quets, J. E. Maley, and T. Ueda Sulcal Hyperintensity on Fluid-Attenuated Inversion Recovery MR Images in Patients Without Apparent Cerebrospinal Fluid Abnormality Am. J. Roentgenol., February 1, 2001; 176(2): 519 - 524. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. V. Deliganis, D. J. Fisher, A. M. Lam, and K. R. Maravilla Cerebrospinal Fluid Signal Intensity Increase on FLAIR MR Images in Patients under General Anesthesia: The Role of Supplemental O2 Radiology, January 1, 2001; 218(1): 152 - 156. [Abstract] [Full Text] |
||||
![]() |
K. Noguchi, H. Seto, Y. Kamisaki, G. Tomizawa, S. Toyoshima, and N. Watanabe Comparison of Fluid-attenuated Inversion-recovery MR Imaging with CT in a Simulated Model of Acute Subarachnoid Hemorrhage AJNR Am. J. Neuroradiol., May 1, 2000; 21(5): 923 - 927. [Abstract] [Full Text] |
||||
![]() |
R. Bakshi, S. Kamran, P. R. Kinkel, V. E. Bates, L. L. Mechtler, V. Janardhan, S. L. Belani, and W. R. Kinkel Fluid-Attenuated Inversion-Recovery MR Imaging in Acute and Subacute Cerebral Intraventricular Hemorrhage AJNR Am. J. Neuroradiol., April 1, 1999; 20(4): 629 - 636. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |