AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Czerny, C.
Right arrow Articles by Trattnig, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Czerny, C.
Right arrow Articles by Trattnig, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 170, 791-796, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

MR imaging of the inner ear and cerebellopontine angle: comparison of three-dimensional and two-dimensional sequences

C Czerny, T Rand, W Gstoettner, G Woelfl, H Imhof and S Trattnig
Department of Radiology, University of Vienna, Austria.

OBJECTIVE: The aim of the study was to compare the ability of three- dimensional (3D) T2-weighted turbo spin-echo and gadolinium-enhanced 3D T1-weighted gradient-echo sequences with two-dimensional (2D) T2- weighted turbo spin-echo and gadolinium-enhanced T1-weighted spin-echo sequences to reveal anatomic and pathologic structures of the inner ear and cerebellopontine angle. SUBJECTS AND METHODS: Thirty-one patients underwent axial 2D T2-weighted turbo spin-echo and 3D T2-weighted turbo spin-echo MR imaging, axial and coronal 2D T1-weighted spin-echo MR imaging before and after i.v. injection of gadopentetate dimeglumine, and gadolinium-enhanced axial 3D T1-weighted gradient-echo MR imaging. The visualization of anatomic and pathologic structures on the different sequences was evaluated. Statistical analysis was performed from the data obtained from the visual evaluation of the anatomic structures on the different sequences. Signal-to-noise and contrast-to- noise ratios were calculated for the gadolinium-enhanced 3D T1-weighted gradient-echo and 2D T1-weighted spin-echo sequences, and statistical evaluation was performed. RESULTS: The 3D sequences enabled excellent visualization of 94% of all evaluated anatomic structures, and the 2D sequences enabled excellent visualization in only 3% of these structures. Pathologic structures were revealed in all cases by one or both of the 3D sequences. Diagnosis in all patients could be made by using the combination of the 3D T2-weighted turbo spin-echo and the gadolinium-enhanced 3D T1-weighted gradient-echo sequences. However, the 2D sequences failed to show pathologic structures in three patients. We found a significant statistical difference for the visualization of anatomic structures with the 3D and 2D sequences (p < .0001) and no significant statistical difference for the signal-to- noise and contrast-to-noise ratios with the 3D T1-weighted gradient- echo and 2D T1-weighted spin-echo sequences. CONCLUSION: The 3D sequences revealed anatomic structures significantly better than did the 2D sequences and showed pathologic structures considerably more often than did the 2D sequences in all patients. MR imaging of the inner ear and cerebellopontine angle performed with 3D T2-weighted turbo spin-echo and gadolinium-enhanced 3D T1-weighted gradient-echo sequences provided the most accurate imaging leading to diagnosis in cases of abnormality.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Neuroradiol.Home page
H. R. Harnsberger and C. Shelton
Mass Screening for Retrocochlear Disorders
AJNR Am. J. Neuroradiol., June 1, 2002; 23(6): 897 - 898.
[Full Text] [PDF]


Home page
Arch Otolaryngol Head Neck SurgHome page
R. Klingebiel, N. Thieme, D. Kivelitz, C. Enzweiler, M. Werbs, and R. Lehmann
Three-dimensional Imaging of the Inner Ear by Volume-Rendered Reconstructions of Magnetic Resonance Data
Arch Otolaryngol Head Neck Surg, May 1, 2002; 128(5): 549 - 553.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
S. Naganawa, T. Ito, E. Iwayama, H. Fukatsu, and T. Ishigaki
High-Resolution MR Cisternography of the Cerebellopontine Angle, Obtained with a Three-Dimensional Fast Asymmetric Spin-Echo Sequencein a 0.35-T Open MR Imaging Unit
AJNR Am. J. Neuroradiol., June 1, 1999; 20(6): 1143 - 1147.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
Iwayama, Naganawa, Ito, Fukatsu, Ikeda, Ishigaki, and Ichinose
High-Resolution MR Cisternography of the Cerebellopontine Angle: 2D versus 3D Fast Spin-Echo
AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 889 - 895.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.