|
|
||||||||
American Journal of Roentgenology, Vol 170, 919-923, Copyright © 1998 by American Roentgen Ray Society
ARTICLES |
SW Wise, KD Hopper, T Ten Have and T Schwartz
Department of Radiology, Pennsylvania State University, Milton S. Hershey Medical Center, Hershey 17033, USA.
OBJECTIVE: This study assesses artifactual luminal distortion, or eccentricity, that affects measurement of stenosis on CT angiography performed with a variety of helical protocols. MATERIALS AND METHODS: A 32-vessel carotid artery phantom was built with five known grades of stenoses (25%, 50%, 75%, 88%, and 94%) and three lengths of stenosis (1, 3, and 5 mm). This phantom was scanned with conventional and 1.0-, 1.5-, and 2.0-pitch helical CT with slice thicknesses of 2, 4, and 8 mm, and three vessel orientations: parallel, 45 degrees oblique, and perpendicular to the z-axis. Oblique multiplanar reconstruction was performed with the latter two vessel orientations to produce images similar to the parallel to z-axis orientation. The cross-sectional images were then used to measure the maximum and minimum (longest and shortest) luminal diameters in and out of each stenosis at a computer workstation by a single investigator who was unaware of the scanning technique. Percentage of stenosis was assessed by three methods: cross- sectional area in and out of the stenosis, maximum diameter out of stenosis and minimum in stenosis (North American Symptomatic Carotid Endarterectomy Trial method), and minimum diameter in and out of the stenosis. Comparisons were made with the gold standard using the equation (measured percentage of stenosis-actual percentage of stenosis) based on known luminal diameters of the phantom. Luminal eccentricity was assessed for each of the vessels and scanning parameters as a ratio of minimum to maximum diameters. RESULTS: All three methods of measuring stenoses were strongly affected by luminal eccentricity. The North American Symptomatic Carotid Endarterectomy Trial method overestimated percentage of stenosis an average of 1.64%. The most accurate results were obtained when using the minimum diameter in and out of the stenoses (-0.45% from the gold standard). Eccentricity was significantly greater in stenoses than in normal lumen (p < .0001) and when the vessels were oriented perpendicular to the z- axis (p = .0003). A progressive increase in eccentricity was seen in the 4- and 8-mm slice thicknesses and the 3- and 5-mm-long stenoses (p < .001; p < .001). CONCLUSION: Artifactual luminal eccentricity has significant implications for measuring percentage of stenosis revealed by CT angiography. Eccentricity increases in longer stenoses, thicker slices, and vessels oriented perpendicular to the z-axis. With CT angiography, measurement of minimum diameters in and out of a stenosis provides the most accurate assessment of percentage of stenosis.
This article has been cited by other articles:
![]() |
J. P. Villablanca, F. J. Rodriguez, T. Stockman, S. Dahliwal, M. Omura, S. Hazany, and J. Sayre MDCT Angiography for Detection and Quantification of Small Intracranial Arteries: Comparison with Conventional Catheter Angiography Am. J. Roentgenol., February 1, 2007; 188(2): 593 - 602. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Suzuki, S. Furui, and T. Kaminaga Accuracy of Automated CT Angiography Measurement of Vascular Diameter in Phantoms: Effect of Size of Display Field of View, Density of Contrast Medium, and Wall Thickness Am. J. Roentgenol., June 1, 2005; 184(6): 1940 - 1944. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.-H. Kim, E. M. Marom, J. E. Herndon II, and H. P. McAdams Pulmonary Vein Diameter, Cross-sectional Area, and Shape: CT Analysis Radiology, April 1, 2005; 235(1): 43 - 49. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Suzuki, S. Furui, T. Kaminaga, and T. Yamauchi Measurement of Vascular Diameter In Vitro by Automated Software for CT Angiography: Effects of Inner Diameter, Density of Contrast Medium, and Convolution Kernel Am. J. Roentgenol., May 1, 2004; 182(5): 1313 - 1317. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. S. Smith, H. C. Roberts, N. A. Chuang, K. C. Ong, T. J. Lee, S. C. Johnston, and W. P. Dillon Safety and Feasibility of a CT Protocol for Acute Stroke: Combined CT, CT Angiography, and CT Perfusion Imaging in 53 Consecutive Patients AJNR Am. J. Neuroradiol., April 1, 2003; 24(4): 688 - 690. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Funabashi, Y. Kobayashi, M. Perlroth, and G. D. Rubin Coronary Artery: Quantitative Evaluation of Normal Diameter Determined with Electron-Beam CT Compared with Cine Coronary Angiography--Initial Experience Radiology, January 1, 2003; 226(1): 263 - 271. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Cody AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Image Processing in CT RadioGraphics, September 1, 2002; 22(5): 1255 - 1268. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hernandez-Hoyos, M. Orkisz, P. Puech, C. Mansard-Desbleds, P. Douek, and I. E. Magnin Computer-assisted Analysis of Three-dimensional MR Angiograms RadioGraphics, March 1, 2002; 22(2): 421 - 436. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. A. Addis, K. D. Hopper, T. A. Iyriboz, Y. Liu, S. W. Wise, C. J. Kasales, J. S. Blebea, and D. T. Mauger CT Angiography: In Vitro Comparison of Five Reconstruction Methods Am. J. Roentgenol., November 1, 2001; 177(5): 1171 - 1176. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Liu, K. D. Hopper, D. T. Mauger, and K. A. Addis CT Angiographic Measurement of the Carotid Artery: Optimizing Visualization by Manipulating Window and Level Settings and Contrast Material Attenuation Radiology, November 1, 2000; 217(2): 494 - 500. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |