AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lewin, J. S.
Right arrow Articles by Haaga, J. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lewin, J. S.
Right arrow Articles by Haaga, J. R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 170, 1593-1601, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

Interactive MR imaging-guided biopsy and aspiration with a modified clinical C-arm system

JS Lewin, CA Petersilge, SF Hatem, JL Duerk, G Lenz, ME Clampitt, ML Williams, KR Kaczynski, CF Lanzieri, AL Wise and JR Haaga
Department of Radiology, University Hospitals of Cleveland and Case Western Reserve University, OH 44106, USA.

OBJECTIVE: This investigation was performed to test the hypotheses that interactive guidance of MR image acquisition during needle-directed procedures using a clinical 0.2-T C-arm open MR imaging system integrated with a frameless optically linked stereotaxy system is feasible, and that procedure times can be sufficiently short to be well tolerated by the patient. SUBJECTS AND METHODS: One hundred six MR- guided procedures were performed in 86 patients (ranging in age from 5 months to 88 years) using a clinical C-arm imaging system supplemented with an in-room RF-shielded liquid crystal display monitor, a frameless stereotaxy system, rapid gradient-echo sequences for needle guidance, and MR-compatible monitoring and surgical lighting equipment. We performed 50 biopsies and aspirations of the head and neck in 37 patients, 23 biopsies of musculoskeletal lesions in 22 patients, 16 biopsies of abdominal sites in 10 patients, six biopsies of the thoracolumbar spine or sacrum in six patients, and 11 shoulder joint injections for MR arthrography in 11 patients, in addition to 38 MR arthrographic injections on the same imaging system described in a previous report. Tissue sampling included fine-needle aspiration (n = 90) and cutting needle core biopsy (n = 41). Thirty-five patients underwent both procedures. Procedures were evaluated for success of needle placement, procedure time, and complications. RESULTS: Needle placement was successful in all cases, and no complications occurred. Tissue was sufficient for pathologic diagnosis for all but eight patients. Passes per patient averaged 2.1. For fine-needle aspiration, instrument time averaged 7 min 42 sec per pass, cutting needle core biopsy averaged 6 min 24 sec, and shoulder injection averaged 8 min. CONCLUSION: MR imaging guidance for needle procedures on a clinical 0.2- T C-arm system with supplemental interventional accessories is feasible, with relatively rapid needle placement.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
JBJSHome page
J. A. Carrino, B. Khurana, J. E. Ready, S. G. Silverman, and C. S. Winalski
Magnetic Resonance Imaging-Guided Percutaneous Biopsy of Musculoskeletal Lesions
J. Bone Joint Surg. Am., October 1, 2007; 89(10): 2179 - 2187.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. K. Wacker, S. Vogt, A. Khamene, J. A. Jesberger, S. G. Nour, D. R. Elgort, F. Sauer, J. L. Duerk, and J. S. Lewin
An Augmented Reality System for MR Image-guided Needle Biopsy: Initial Results in a Swine Model
Radiology, February 1, 2006; 238(2): 497 - 504.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. N. Goldberg, C. J. Grassi, J. F. Cardella, J. W. Charboneau, G. D. Dodd II, D. E. Dupuy, D. Gervais, A. R. Gillams, R. A. Kane, F. T. Lee Jr, et al.
Image-guided Tumor Ablation: Standardization of Terminology and Reporting Criteria
Radiology, June 1, 2005; 235(3): 728 - 739.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. T. Boll, E. M. Merkle, and J. S. Lewin
Low-Flow Vascular Malformations: MR-guided Percutaneous Sclerotherapy in Qualitative and Quantitative Assessment of Therapy and Outcome
Radiology, November 1, 2004; 233(2): 376 - 384.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P. M. Sherman, D. M. Yousem, and L. A. Loevner
CT-Guided Aspirations in the Head and Neck: Assessment of the First 216 Cases
AJNR Am. J. Neuroradiol., October 1, 2004; 25(9): 1603 - 1607.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. G. Nour, J. S. Lewin, M. Gutman, C. Hillenbrand, F. K. Wacker, J. W. Wong, I. C. Mitchell, C. B. Armstrong, M. M. Hashim, J. L. Duerk, et al.
Percutaneous MR Imaging- guided Radiofrequency Interstitial Thermal Ablation of Tongue Base in Porcine Models: Implications for Obstructive Sleep Apnea Syndrome
Radiology, February 1, 2004; 230(2): 359 - 368.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. N. Goldberg, J. W. Charboneau, G. D. Dodd III, D. E. Dupuy, D. A. Gervais, A. R. Gillams, R. A. Kane, F. T. Lee Jr, T. Livraghi, J. P. McGahan, et al.
Image-guided Tumor Ablation: Proposal for Standardization of Terms and Reporting Criteria
Radiology, August 1, 2003; 228(2): 335 - 345.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. W. Konig, P. L. Pereira, J. Trubenbach, J. Fritz, S. H. Duda, F. Schick, and C. D. Claussen
MR Imaging-Guided Adrenal Biopsy Using an Open Low-Field-Strength Scanner and MR Fluoroscopy
Am. J. Roentgenol., June 1, 2003; 180(6): 1567 - 1570.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
N. Hayashi, T. Masumoto, T. Okubo, O. Abe, N. Kaji, K. Tokioka, S. Aoki, and K. Ohtomo
Hemangiomas in the Face and Extremities: MR-guided Sclerotherapy--Optimization with Monitoring of Signal Intensity Changes in Vivo
Radiology, February 1, 2003; 226(2): 567 - 572.
[Abstract] [Full Text] [PDF]


Home page
JBJSHome page
C. S. Winalski, M. I. Robbins, S. G. Silverman, and J. A.K. Davies
Interactive Magnetic Resonance Image-Guided Aspiration Therapy of a Glenoid Labral Cyst : A Case Report
J. Bone Joint Surg. Am., August 1, 2001; 83(8): 1237 - 1242.
[Full Text]


Home page
RadiologyHome page
E. M. Merkle, J. R. Haaga, J. L. Duerk, G. H. Jacobs, H.-J. Brambs, and J. S. Lewin
MR Imaging-guided Radio-frequency Thermal Ablation in the Pancreas in a Porcine Model with a Modified Clinical C-Arm System
Radiology, November 1, 1999; 213(2): 461 - 467.
[Abstract] [Full Text]


Home page
Am. J. Neuroradiol.Home page
J. Lewin
Interventional MR Imaging: Concepts, Systems, and Applications in
AJNR Am. J. Neuroradiol., May 1, 1999; 20(5): 735 - 748.
[Full Text]


Home page
RadiologyHome page
J. S. Lewin, E. M. Merkle, J. L. Duerk, and R. W. Tarr
Low-Flow Vascular Malformations in the Head and Neck: Safety and Feasibility of MR Imaging–guided Percutaneous Sclerotherapy—Preliminary Experience with 14 Procedures in Three Patients
Radiology, May 1, 1999; 211(2): 566 - 570.
[Abstract] [Full Text]


Home page
RadiologyHome page
J. W. Genant, J. E. Vandevenne, A. G. Bergman, C. F. Beaulieu, S. T. Kee, A. M. Norbash, and P. Lang
Interventional Musculoskeletal Procedures Performed by Using MR Imaging Guidance with a Vertically Open MR Unit: Assessment of Techniques and Applicability
Radiology, April 1, 2002; 223(1): 127 - 136.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.