AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Nolte-Ernsting, C.
Right arrow Articles by Gunther, R. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Nolte-Ernsting, C.
Right arrow Articles by Gunther, R. W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 171, 107-113, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

Abdominal MR angiography performed using blood pool contrast agents: comparison of a new superparamagnetic iron oxide nanoparticle and a linear gadolinium polymer

C Nolte-Ernsting, G Adam, A Bucker, S Berges, A Bjornerud and RW Gunther
Department of Diagnostic Radiology, University of Technology, Aachen, Germany.

OBJECTIVE: We evaluated and compared two different experimental blood pool contrast agents for abdominal MR angiography in an animal model. MATERIALS AND METHODS: In seven pigs, coronal T1-weighted three- dimensional fast field-echo images were obtained on a conventional 1.5- T MR imaging system before and after i.v. injection of the ultrasmall superparamagnetic iron oxide agent FeO-BPA. In another seven pigs, MR angiograms were acquired using the gadolinium polymer WIN 22181. Enhanced images were obtained 5-210 min after injection of FeO-BPA and 1-120 min after injection of WIN 22181. RESULTS: Both blood pool agents yielded detailed angiograms of the abdominal vascular tree when imaging lasted 2 min. In-plane running vessels were imaged without saturation effects and with equivalent maximum signal-to-noise ratios. Half the maximum signal-to-noise ratio was reached 150 min after injection of FeO-BPA, whereas this interval was approximately 70 min for the gadolinium polymer. Because of these different imaging half-life periods, the effective diagnostic window provided by FeO-BPA was six to eight times longer than that of WIN 22181. In the liver, the vascular T1 shortening and the parenchymal T2* effect of FeO-BPA complemented each other, resulting in an optimal contrast-to-noise ratio significantly higher than that achieved with WIN 22181. This "double- contrast effect" in the liver was especially helpful when obtaining detailed MR portograms. CONCLUSION: The blood pool agents FeO-BPA and WIN 22181 can be used to produce high-quality abdominal MR angiograms on standard MR imaging equipment. The contrast-to-noise ratio of hepatic vessels is best on iron oxide-enhanced images because of a T1- T2* synergistic effect in the liver. The longer diagnostic window provided by FeO-BPA coupled with the option of in-plane imaging suggests the usefulness of FeO-BPA in future MR imaging-guided vascular interventions.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadioGraphicsHome page
S. N. Gandhi, M. A. Brown, J. G. Wong, D. A. Aguirre, and C. B. Sirlin
MR Contrast Agents for Liver Imaging: What, When, How
RadioGraphics, November 1, 2006; 26(6): 1621 - 1636.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. K. Wacker, K. Reither, W. Ebert, M. Wendt, J. S. Lewin, and K.-J. Wolf
MR Image-guided Endovascular Procedures with the Ultrasmall Superparamagnetic Iron Oxide SH U 555 C as an Intravascular Contrast Agent: Study in Pigs
Radiology, February 1, 2003; 226(2): 459 - 464.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E.-M. Larsson, P. Sunden, C.-G. Olsson, J. Debatin, A. J. Duerinckx, R. Baum, D. Hahn, and F. Ebner
MR Venography Using an Intravascular Contrast Agent: Results from a Multicenter Phase 2 Study of Dosage
Am. J. Roentgenol., January 1, 2003; 180(1): 227 - 232.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. F. Glockner
Three-dimensional Gadolinium-enhanced MR Angiography: Applications for Abdominal Imaging
RadioGraphics, March 1, 2001; 21(2): 357 - 370.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Weishaupt, S. G. Ruhm, C. A. Binkert, M. Schmidt, M. A. Patak, F. Steybe, S. McGill, and J. F. Debatin
Equilibrium-Phase MR Angiography of the Aortoiliac and Renal Arteries Using a Blood Pool Contrast Agent
Am. J. Roentgenol., July 1, 2000; 175(1): 189 - 195.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. E. Clarke, H.-J. Weinmann, E. Dai, A. R. Lucas, and B. K. Rutt
Comparison of Two Blood Pool Contrast Agents for 0.5-T MR Angiography: Experimental Study in Rabbits
Radiology, March 1, 2000; 214(3): 787 - 794.
[Abstract] [Full Text]


Home page
RadiologyHome page
K. H. Ahlström, L. O. Johansson, J. B. Rodenburg, A. S. Ragnarsson, P. Åkeson, and A. Börseth
Pulmonary MR Angiography with Ultrasmall Superparamagnetic Iron Oxide Particles as a Blood Pool Agent and a Navigator Echo for Respiratory Gating: Pilot Study
Radiology, June 1, 1999; 211(3): 865 - 869.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.