AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Strotzer, M.
Right arrow Articles by Feuerbach, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Strotzer, M.
Right arrow Articles by Feuerbach, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 171, 23-27, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

Clinical application of a flat-panel X-ray detector based on amorphous silicon technology: image quality and potential for radiation dose reduction in skeletal radiography

M Strotzer, J Gmeinwieser, M Volk, R Frund, J Seitz, C Manke, H Albrich and S Feuerbach
Department of Diagnostic Radiology, University Hospital of Regensburg, Germany.

OBJECTIVE: The purpose of this study was to compare images obtained with a self-scanning, flat-panel X-ray detector based on amorphous silicon technology with conventional screen-film radiographs and to evaluate the possibility of radiation dose reduction in skeletal radiography. SUBJECTS AND METHODS: One hundred twenty patients were examined prospectively using a conventional screen-film system (speed, 400; detector dose, 2.5 microGy) and a prototype digital amorphous silicon detector (simulated speed, 400 and 800, n = 120; simulated speed, 1600, n = 40). The resulting 400 images were evaluated independently by six radiologists using a subjective five-point preference scale that rated overexposure, underexposure, contrast resolution, spatial resolution, and soft-tissue presentation. Image quality was ranked on a scale from 0 to 10 according to subjective criteria. Statistical significance of differences was determined using Student's t test and confidence intervals (95% confidence level). RESULTS: Comparison of conventional radiographs with digital images revealed a statistically significant preference for the digital system for soft-tissue presentation (speed 400 and 800) and visualization of osteoarthrotic changes (speed 400). A small but statistically significant preference for conventional images was found with respect to contrast and spatial resolution when digital speed was 800 or 1600; and the visibility of arthrosis at digital speed 1600, osteolysis at digital speed 800 and 1600, and fractures at digital speed 1600. CONCLUSION: The amorphous silicon-based system with a simulated speed of 400 provided images equivalent to screen-film radiographs. For clinical tasks such as routine follow-up studies, assessment of instability, or orthopedic measurements, a radiation dose reduction of up to 75% may be possible.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadioGraphicsHome page
M. Korner, C. H. Weber, S. Wirth, K.-J. Pfeifer, M. F. Reiser, and M. Treitl
Advances in Digital Radiography: Physical Principles and System Overview
RadioGraphics, May 1, 2007; 27(3): 675 - 686.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
Y. Hatakeyama, S. Kakeda, N. Ohnari, J. Moriya, N. Oda, K. Nishino, W. Miyamoto, and Y. Korogi
Reduction of Radiation Dose for Cerebral Angiography Using Flat Panel Detector of Direct Conversion Type: A Vascular Phantom Study
AJNR Am. J. Neuroradiol., April 1, 2007; 28(4): 645 - 650.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
H. P. Busch and K. Faulkner
Image quality and dose management in digital radiography: a new paradigm for optimisation
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 143 - 147.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Neofotistou, V. Tsapaki, S. Kottou, A. Schreiner-Karoussou, and E. Vano
Does digital imaging decrease patient dose? A pilot study and review of the literature
Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 204 - 210.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Suzuki, S. Furui, I. Kobayashi, T. Yamauchi, H. Kohtake, K. Takeshita, K. Takada, and M. Yamagishi
Radiation Dose to Patients and Radiologists During Transcatheter Arterial Embolization: Comparison of a Digital Flat-Panel System and Conventional Unit
Am. J. Roentgenol., October 1, 2005; 185(4): 855 - 859.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Bacher, P. Smeets, K. Bonnarens, An De Hauwere, K. Verstraete, and H. Thierens
Dose Reduction in Patients Undergoing Chest Imaging: Digital Amorphous Silicon Flat-Panel Detector Radiography Versus Conventional Film-Screen Radiography and Phosphor-Based Computed Radiography
Am. J. Roentgenol., October 1, 2003; 181(4): 923 - 929.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Ludwig, K. Ahlers, D. Wormanns, M. Freund, T. M. Bernhardt, S. Diederich, and W. Heindel
Lumbar Spine Radiography: Digital Flat-Panel Detector versus Screen-Film and Storage-Phosphor Systems in Monkeys as a Pediatric Model
Radiology, October 1, 2003; 229(1): 140 - 144.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
U. Rapp-Bernhardt, F. W. Roehl, R. C. Gibbs, H. Schmidl, U. W. Krause, and T. M. Bernhardt
Flat-Panel X-ray Detector Based on Amorphous Silicon versus Asymmetric Screen-Film System: Phantom Study of Dose Reduction and Depiction of Simulated Findings
Radiology, May 1, 2003; 227(2): 484 - 492.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Ludwig, C. Schulke, S. Diederich, D. Wormanns, H. Lenzen, T. M. Bernhardt, P. Brinckmann, and W. Heindel
Detection of Subtle Undisplaced Rib Fractures in a Porcine Model: Radiation Dose Requirement--Digital Flat-Panel versus Screen-Film and Storage-Phosphor Systems
Radiology, April 1, 2003; 227(1): 163 - 168.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Strotzer, M. Volk, R. Frund, O. Hamer, N. Zorger, and S. Feuerbach
Routine Chest Radiography Using a Flat-Panel Detector: Image Quality at Standard Detector Dose and 33% Dose Reduction
Am. J. Roentgenol., January 1, 2002; 178(1): 169 - 171.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Strotzer, M. Völk, T. Wild, P. von Landenberg, and S. Feuerbach
Simulated Bone Erosions in a Hand Phantom: Detection with Conventional Screen-Film Technology versus Cesium Iodide-Amorphous Silicon Flat-Panel Detector
Radiology, May 1, 2000; 215(2): 512 - 515.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. Garmer, S. P. Hennigs, H. J. Jager, F. Schrick, T. van de Loo, A. Jacobs, A. Hanusch, A. Christmann, and K. Mathias
Digital Radiography Versus Conventional Radiography in Chest Imaging: Diagnostic Performance of a Large-Area Silicon Flat-Panel Detector in a Clinical CT-Controlled Study
Am. J. Roentgenol., January 1, 2000; 174(1): 75 - 80.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Ludwig, H. Lenzen, K.-F. Kamm, T. M. Link, S. Diederich, D. Wormanns, and W. Heindel
Performance of a Flat-Panel Detector in Detecting Artificial Bone Lesions: Comparison with Conventional Screen-Film and Storage-Phosphor Radiography
Radiology, February 1, 2002; 222(2): 453 - 459.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.