AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shapiro, R. S.
Right arrow Articles by Lao, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shapiro, R. S.
Right arrow Articles by Lao, R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 171, 1203-1206, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

Tissue harmonic imaging sonography: evaluation of image quality compared with conventional sonography

RS Shapiro, J Wagreich, RB Parsons, A Stancato-Pasik, HC Yeh and R Lao
Department of Radiology, Mount Sinai Medical Center, New York, NY 10029- 6574, USA.

OBJECTIVE: The purpose of this study was to determine if tissue harmonic imaging (THI) sonography produced higher quality images than did conventional sonography. SUBJECTS AND METHODS: A prospective study was performed on 89 patients to compare the image quality of THI sonography with that of conventional sonography. Each examination was performed using THI sonography (transmitted frequency, 2.0 MHz; received frequency, 4.0 MHz) and conventional sonography at 2.5 and 4.0 MHz. The pancreatic area was studied in 60 patients, and other anatomic areas were studied in 68 patients. The images were then graded for penetration, detail, and total image quality. Graders were unaware of the sonographic technique. RESULTS: Of the 60 pancreatic examinations, THI sonography was the best technique for penetration in 45, detail in 54, and total image quality in 50. For the pancreas, THI sonography was significantly better than 2.5-MHz conventional sonography for penetration (p = .0002), detail (p < .0001), and total image quality (p < .0001). THI sonography was significantly better than 4.0-MHz conventional sonography for penetration (p < .0001), detail (p < .0001), and total image quality (p < .0001). Of the 68 examinations of other anatomic areas, THI sonography was the best technique for penetration in 42, detail in 57, and total image quality in 58. For other anatomic areas, THI sonography was significantly better than 2.5- MHz conventional sonography for penetration (p = .05), detail (p < .0001), and total image quality (p < .0001). THI sonography was significantly better than 4.0-MHz conventional sonography for penetration (p < .0001), detail (p < .0001), and total image quality (p < .0001). CONCLUSION: The THI technique improved sonographic image quality.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J Ultrasound MedHome page
G. Francica, S. A. Bellini, F. Scarano, A. Miragliuolo, F. A. De Marino, and M. Maniscalco
Correlation of Transabdominal Sonographic and Cystoscopic Findings in the Diagnosis of Focal Abnormalities of the Urinary Bladder Wall: A Prospective Study
J. Ultrasound Med., June 1, 2008; 27(6): 887 - 894.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
S.-Y. Chiou, F. Forsberg, T. B. Fox, and L. Needleman
Comparing Differential Tissue Harmonic Imaging With Tissue Harmonic and Fundamental Gray Scale Imaging of the Liver
J. Ultrasound Med., November 1, 2007; 26(11): 1557 - 1563.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Schueller-Weidekamm, C. Krestan, G. Schueller, T. Kapral, D. Aletaha, and F. Kainberger
Power Doppler Sonography and Pulse-Inversion Harmonic Imaging in Evaluation of Rheumatoid Arthritis Synovitis
Am. J. Roentgenol., February 1, 2007; 188(2): 504 - 508.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
K. Yabunaka, T. Katsuda, S. Sanada, and T. Fukutomi
Sonographic Appearance of the Normal Appendix in Adults
J. Ultrasound Med., January 1, 2007; 26(1): 37 - 43.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. H. Cha, W. K. Moon, N. Cho, S. M. Kim, S. H. Park, B.-K. Han, Y. H. Choe, J. M. Park, and J.-G. Im
Characterization of Benign and Malignant Solid Breast Masses: Comparison of Conventional US and Tissue Harmonic Imaging
Radiology, December 1, 2006; 242(1): 63 - 69.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. C. Lee and J. C. Healy
Normal Sonographic Anatomy of the Wrist and Hand
RadioGraphics, November 1, 2005; 25(6): 1577 - 1590.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
H Maruyama, S Matsutani, H Saisho, Y Mine, N Kamiyama, T Hirata, and M Sasamata
Real-time blood-pool images of contrast enhanced ultrasound with Definity in the detection of tumour nodules in the liver
Br. J. Radiol., June 1, 2005; 78(930): 512 - 518.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. Y. Kwak, E.-K. Kim, J. K. You, and K. K. Oh
Variable Breast Conditions: Comparison of Conventional and Real-time Compound Ultrasonography
J. Ultrasound Med., January 1, 2004; 23(1): 85 - 96.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Strobel, M. Zanetti, L. Nagy, and J. Hodler
Suspected Rotator Cuff Lesions: Tissue Harmonic Imaging versus Conventional US of the Shoulder
Radiology, January 1, 2004; 230(1): 243 - 249.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. O. Oktar, C. Yucel, H. Ozdemir, A. Uluturk, and S. Isik
Comparison of Conventional Sonography, Real-Time Compound Sonography, Tissue Harmonic Sonography, and Tissue Harmonic Compound Sonography of Abdominal and Pelvic Lesions
Am. J. Roentgenol., November 1, 2003; 181(5): 1341 - 1347.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. H. Youk, J. M. Lee, and C. S. Kim
Therapeutic Response Evaluation of Malignant Hepatic Masses Treated by Interventional Procedures With Contrast-Enhanced Agent Detection Imaging
J. Ultrasound Med., September 1, 2003; 22(9): 911 - 920.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Schmidt, C. Hohl, P. Haage, M. Blaum, D. Honnef, C. Weiss, G. Staatz, and R. W. Gunther
Diagnostic Accuracy of Phase-Inversion Tissue Harmonic Imaging Versus Fundamental B-Mode Sonography in the Evaluation of Focal Lesions of the Kidney
Am. J. Roentgenol., June 1, 2003; 180(6): 1639 - 1647.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
I. Leconte, C. Feger, C. Galant, M. Berliere, B. V. Berg, W. D'Hoore, and B. Maldague
Mammography and Subsequent Whole-Breast Sonography of Nonpalpable Breast Cancers: The Importance of Radiologic Breast Density
Am. J. Roentgenol., June 1, 2003; 180(6): 1675 - 1679.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
K. T. Szopinski, A. M. Pajk, M. Wysocki, D. Amy, M. Szopinska, and W. Jakubowski
Tissue Harmonic Imaging: Utility in Breast Sonography
J. Ultrasound Med., May 1, 2003; 22(5): 479 - 487.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
K. T. Szopinski, M. Wysocki, A. M. Pajk, R. Z. Slapa, W. Jakubowski, and M. Szopinska
Tissue Harmonic Imaging of Thyroid Nodules: Initial Experience
J. Ultrasound Med., January 1, 2003; 22(1): 5 - 12.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. J. Rosenthal, P. H. Jones, and L. H. Wetzel
Phase Inversion Tissue Harmonic Sonographic Imaging: A Clinical Utility Study
Am. J. Roentgenol., June 1, 2001; 176(6): 1393 - 1398.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Ortega, P. N. Burns, D. Hope Simpson, and S. R. Wilson
Tissue Harmonic Imaging: Is It a Benefit for Bile Duct Sonography?
Am. J. Roentgenol., March 1, 2001; 176(3): 653 - 659.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. K. Kim, B. I. Choi, J. K. Han, H.-S. Hong, S. H. Park, and S. G. Moon
Hepatic Tumors: Contrast Agent-Enhancement Patterns with Pulse-Inversion Harmonic US
Radiology, August 1, 2000; 216(2): 411 - 417.
[Abstract] [Full Text]


Home page
RadiologyHome page
B. I. Choi, T. K. Kim, J. K. Han, A. Y. Kim, C. K. Seong, and S. J. Park
Vascularity of Hepatocellular Carcinoma: Assessment with Contrast-enhanced SecondHarmonic versus Conventional Power Doppler US
Radiology, February 1, 2000; 214(2): 381 - 386.
[Abstract] [Full Text]


Home page
BMJHome page
J. Hawnaur
Recent advances: Diagnostic radiology
BMJ, July 17, 1999; 319(7203): 168 - 171.
[Full Text]


Home page
RadiologyHome page
H. Ding, M. Kudo, H. Onda, Y. Suetomi, Y. Minami, H. Chung, T. Kawasaki, and K. Maekawa
Evaluation of Posttreatment Response of Hepatocellular Carcinoma with Contrast-enhanced Coded Phase-Inversion Harmonic US: Comparison with Dynamic CT
Radiology, December 1, 2001; 221(3): 721 - 730.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.