AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sheiman, R. G.
Right arrow Articles by Raptopoulos, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sheiman, R. G.
Right arrow Articles by Raptopoulos, V.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 171, 1291-1295, Copyright © 1998 by American Roentgen Ray Society


ARTICLES

CT detection of layering of i.v. contrast material in the abdominal aorta

RG Sheiman, P Prassopoulos and V Raptopoulos
Department of Radiology, Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA 02215, USA.

OBJECTIVE: We sought to determine whether IV contrast material would layer dependently within the abdominal aorta if administered from a location and at a rate routinely used for CT angiography. SUBJECTS AND METHODS: In 22 patients, three equal-sized regions of interest (ROIs) were symmetrically spaced across the abdominal aortic lumen at the level of the celiac axis. These positions corresponded to a dependent, a central, and a nondependent position. Time-enhancement curves were generated for each ROI after IV injection of 10 ml of nonionic contrast material, which was administered at a rate of 3.5 ml/sec, through an antecubital vein. The magnitude of and the time to peak enhancement for each ROI were determined. The 22 peak enhancement values obtained for each of the three ROIs were compared using the Newman-Keuls test. RESULTS: A statistically significant increase in peak enhancement was identified when traversing the abdominal aortic lumen from the nondependent to the central ROI (p < .05) and from the central to the dependent ROI (p < .01). Levels of mean peak enhancement were 48.3+/- 19.0, 38.9+/-18.2, and 33.0+/-19.7 for the dependent, central, and nondependent ROIs, respectively. The amount of time needed to reach peak enhancement of each of the three ROIs in an individual patient was similar. CONCLUSION: A small dose of contrast material administered IV through an antecubital vein will layer dependently in the abdominal aorta--thus creating a gradient in enhancement--despite mixing in the heart. If layering of contrast material is subsequently detected during routine abdominal CT angiography, then patient positioning may need to be adjusted to maximize enhancement of targeted vessels.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1998 by the American Roentgen Ray Society.