AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Platt, J. F.
Right arrow Articles by Ellis, J. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Platt, J. F.
Right arrow Articles by Ellis, J. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 172, 53-56, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

Aortic enhancement during abdominal CT angiography: correlation with test injections, flow rates, and patient demographics

JF Platt, KA Reige and JH Ellis
Department of Radiology, University of Michigan Medical Center, Ann Arbor 48109-0030, USA.

OBJECTIVE: The goal of our study was to determine the effect of contrast material injection rate and patient demographic variables on vascular enhancement for abdominal CT angiography and compare test injection results with actual patterns of vascular enhancement. SUBJECTS AND METHODS: One hundred twenty-five patients underwent abdominal CT angiography. For each patient, CT attenuation values (Hounsfield units) of the aorta were determined before and after IV contrast administration, every 3 sec between 21 and 60 sec. A peak aortic enhancement value and the time needed to reach peak and aortic enhancement thresholds of 150 and 200 H were determined. All patients received 150 ml of nonionic contrast material at 3 ml/sec in 25 patients and 4 ml/sec in 100 patients. A test injection of 15 ml was used to compute a scan delay in 46 patients. Patient age, sex, weight, injection rate, and test injection results were compared with vascular enhancement patterns. RESULTS: For the 125 patients, the mean aortic enhancement at each time point was greater than 150 H. Patient weight was inversely correlated (r2 = -.62) with aortic enhancement. The test injection did not accurately predict actual aortic enhancement peak value or time. Test injection delay time was significantly correlated with time to reach aortic enhancement thresholds of 150 and 200 H. The 4 ml/sec rate resulted in a higher peak aortic enhancement (320+/-58 H versus 281+/-49 H) (mean +/- SD, p < .01) that was reached quicker than with the 3 ml/sec injection rate (45+/-5 sec versus 52+/-5 sec) (p < .01). Injecting at 4 ml/sec resulted in greater aortic enhancement values at 24-45 sec, whereas 3 ml/sec produced significantly better aortic enhancement at 54-60 sec. CONCLUSION: The test injection correlated better with time to reach specific aortic enhancement thresholds than with time to peak aortic enhancement. For a given amount of contrast material, faster injection rates resulted in greater vascular enhancement that occurred earlier.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. T. Bae, B. A. Seeck, C. F. Hildebolt, C. Tao, F. Zhu, M. Kanematsu, and P. K. Woodard
Contrast Enhancement in Cardiovascular MDCT: Effect of Body Weight, Height, Body Surface Area, Body Mass Index, and Obesity
Am. J. Roentgenol., March 1, 2008; 190(3): 777 - 784.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. L. Chu, B. N. Joe, A. C. A. Westphalen, E. M. Webb, F. V. Coakley, and B. M. Yeh
Patient-specific Time to Peak Abdominal Organ Enhancement Varies with Time to Peak Aortic Enhancement at MR Imaging
Radiology, December 1, 2007; 245(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. W. Stavropoulos and S. R. Charagundla
Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair
Radiology, June 1, 2007; 243(3): 641 - 655.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. M. Ho, R. C. Nelson, and D. M. DeLong
Determining Contrast Medium Dose and Rate on Basis of Lean Body Weight: Does This Strategy Improve Patient-to-Patient Uniformity of Hepatic Enhancement during Multi-Detector Row CT?
Radiology, May 1, 2007; 243(2): 431 - 437.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. T. Bae, C. Tao, S. Gurel, C. Hong, F. Zhu, T. A. Gebke, M. Milite, and C. F. Hildebolt
Effect of Patient Weight and Scanning Duration on Contrast Enhancement during Pulmonary Multidetector CT Angiography
Radiology, February 1, 2007; 242(2): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Schoellnast, H. A. Deutschmann, A. Berghold, G. A. Fritz, G. J. Schaffler, and M. Tillich
MDCT Angiography of the Pulmonary Arteries: Influence of Body Weight, Body Mass Index, and Scan Length on Arterial Enhancement at Different Iodine Flow Rates
Am. J. Roentgenol., October 1, 2006; 187(4): 1074 - 1078.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Utsunomiya, K. Awai, Y. Tamura, T. Nishiharu, J. Urata, T. Sakamoto, A. Taniguchi, and Y. Yamashita
16-MDCT Aortography with a Low-Dose Contrast Material Protocol
Am. J. Roentgenol., February 1, 2006; 186(2): 374 - 378.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Awai, A. Hatcho, Y. Nakayama, S. Kusunoki, D. Liu, M. Hatemura, Y. Funama, M. Denbo, N. Sato, and Y. Yamashita
Simulation of Aortic Peak Enhancement on MDCT Using a Contrast Material Flow Phantom: Feasibility Study
Am. J. Roentgenol., February 1, 2006; 186(2): 379 - 385.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. de Monye, F. Cademartiri, T. T. de Weert, D. A. M. Siepman, D. W. J. Dippel, and A. van Der Lugt
Sixteen-Detector Row CT Angiography of Carotid Arteries: Comparison of Different Volumes of Contrast Material with and without a Bolus Chaser
Radiology, November 1, 2005; 237(2): 555 - 562.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. J. Ruppert-Kohlmayr, M. Uggowitzer, T. Meissnitzer, and G. Ruppert
Differentiation of Renal Clear Cell Carcinoma and Renal Papillary Carcinoma Using Quantitative CT Enhancement Parameters
Am. J. Roentgenol., November 1, 2004; 183(5): 1387 - 1391.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. M. Ho, R. C. Nelson, J. Thomas, E. I. Gimenez, and D. M. DeLong
Abdominal Aortic Aneurysms at Multi-Detector Row Helical CT: Optimization with Interactive Determination of Scanning Delay and Contrast Medium Dose
Radiology, September 1, 2004; 232(3): 854 - 859.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Vernhet, J. M. Serfaty, M. Serhal, E. McFadden, E. Bonnefoy, P. Adeleine, D. Revel, and P. Douek
Abdominal CT Angiography Before Surgery as a Predictor of Postoperative Death in Acute Aortic Dissection
Am. J. Roentgenol., April 1, 2004; 182(4): 875 - 879.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
K. Awai, K. Hiraishi, and S. Hori
Effect of Contrast Material Injection Duration and Rate on Aortic Peak Time and Peak Enhancement at Dynamic CT Involving Injection Protocol with Dose Tailored to Patient Weight
Radiology, January 1, 2004; 230(1): 142 - 150.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
I. R. Francis, R. H. Cohan, N. J. McNulty, J. F. Platt, M. Korobkin, A. Gebremariam, and K. Ragupathi
Multidetector CT of the Liver and Hepatic Neoplasms: Effect of Multiphasic Imaging on Tumor Conspicuity and Vascular Enhancement
Am. J. Roentgenol., May 1, 2003; 180(5): 1217 - 1224.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. Macari, G. M. Israel, P. Berman, M. Lisi, A. J. Tolia, M. Adelman, and A. J. Megibow
Infrarenal Abdominal Aortic Aneurysms at Multi-Detector Row CT Angiography: Intravascular Enhancement without a Timing Acquisition
Radiology, August 1, 2001; 220(2): 519 - 523.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Kim, M. P. Federle, R. L. Baron, M. S. Peterson, and Y. Kawamori
Discrimination of Small Hepatic Hemangiomas from Hypervascular Malignant Tumors Smaller than 3 cm with Three-Phase Helical CT
Radiology, June 1, 2001; 219(3): 699 - 706.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
Y. H. Choe, L. H. Phyun, and B.-K. Han
Biphasic and Discontinuous Injection of Contrast Material for Thin-Section Helical CT Angiography of the Whole Aorta and Iliac Arteries
Am. J. Roentgenol., February 1, 2001; 176(2): 454 - 456.
[Full Text] [PDF]


Home page
RadiologyHome page
D. Fleischmann, G. D. Rubin, A. A. Bankier, and K. Hittmair
Improved Uniformity of Aortic Enhancement with Customized Contrast Medium Injection Protocols at CT Angiography
Radiology, February 1, 2000; 214(2): 363 - 371.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Roentgen Ray Society.