AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Philpotts, L. E.
Right arrow Articles by Lee, C. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Philpotts, L. E.
Right arrow Articles by Lee, C. H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 172, 683-687, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

Comparison of rebiopsy rates after stereotactic core needle biopsy of the breast with 11-gauge vacuum suction probe versus 14-gauge needle and automatic gun

LE Philpotts, NA Shaheen, D Carter, RC Lange and CH Lee
Department of Diagnostic Radiology, Yale University School of Medicine, New Haven, CT 06520, USA.

OBJECTIVE: The 11-gauge vacuum suction probe is an alternative to the 14-gauge needle and automatic gun for performing stereotactic core needle biopsies. This study compares rebiopsy rates after stereotactic core needle biopsies that were performed with the two methods. The study also assesses the outcomes of those repeat biopsies. MATERIALS AND METHODS: Five hundred ninety-two stereotactic core needle biopsies using a 14-gauge needle and automatic gun and 354 using an 11-gauge vacuum suction probe were performed consecutively. Excluding malignancies, the number of cases requiring rebiopsy and the reasons for rebiopsy were determined for each group. The histologic diagnoses of the repeat biopsies were assessed. RESULTS: The rebiopsy rate was significantly lower with the 11-gauge vacuum suction probe (9.0%) than with the 14-gauge needle and automatic gun (14.9%) (p = .013). Significant reductions were found in cases of insufficient sampling (probe, 1.7%; needle, 4.4%; p = .042) and mammographic-pathologic discrepancy (probe, 0.8%; needle, 3.4%; p = .026). The rebiopsy rate for masses was 6.1% with the vacuum probe versus 10.7% with the 14- gauge needle (p = .12) and for calcifications was 11.6% with the vacuum probe versus 23.7% with the 14-gauge needle (p = .003). After rebiopsy, the percentage of cases in which malignancy was found was 18.5% with the vacuum probe versus 13.7% with the 14-gauge needle. On rebiopsy, the percentage of malignancies found in each category were atypical hyperplasia: probe 26.7%, needle 20.0%; insufficient sample: probe 0%, needle 9.5%; pathologist recommendation: probe 50.0%, needle 12.5%; and lobular carcinoma in situ: probe 0%, needle 100%. CONCLUSION: Use of the 11-gauge vacuum-assisted device significantly decreases but does not eliminate the need for rebiopsy after stereotactic core needle biopsy. The rebiopsy rate for calcifications was significantly reduced by using the vacuum suction probe rather than the 14-gauge needle; however, the rate for masses was reduced only slightly. On rebiopsy, malignancies were found in both groups.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J. Clin. Pathol.Home page
E A Rakha and I O Ellis
An overview of assessment of prognostic and predictive factors in breast cancer needle core biopsy specimens
J. Clin. Pathol., December 1, 2007; 60(12): 1300 - 1306.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J.-M. Lee, J. B. Kaplan, M. P. Murray, L. Bartella, E. A. Morris, S. Joo, D. D. Dershaw, and L. Liberman
Imaging Histologic Discordance at MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., October 1, 2007; 189(4): 852 - 859.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
V. Sohn, Z. Arthurs, G. Herbert, J. Keylock, J. Perry, M. Eckert, D. Fellabaum, D. Smith, and T. Brown
Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle
Ann. Surg. Oncol., September 1, 2007; 14(9): 2497 - 2501.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
J. H. Youk, E.-K. Kim, M. J. Kim, J. Y. Lee, and K. K. Oh
Missed Breast Cancers at US-guided Core Needle Biopsy: How to Reduce Them
RadioGraphics, January 1, 2007; 27(1): 79 - 94.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman and J. Rodriguez-Soto
Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.
Radiology, April 1, 2006; 239(1): 61 - 70.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
J. K. You, E.-K. Kim, J. Y. Kwak, M. J. Kim, K. K. Oh, B.-W. Park, and W. I. Yang
Focal Fibrosis of the Breast Diagnosed by a Sonographically Guided Core Biopsy of Nonpalpable Lesions: Imaging Findings and Clinical Relevance
J. Ultrasound Med., October 1, 2005; 24(10): 1377 - 1384.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. K. Koskela, M. Sudah, M. H. Berg, V. J. Karja, P. K. Mustonen, V. Kataja, and R. S. Vanninen
Add-on Device for Stereotactic Core-Needle Breast Biopsy: How Many Biopsy Specimens Are Needed for a Reliable Diagnosis?
Radiology, September 1, 2005; 236(3): 801 - 809.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. D. Lehman, E. R. DePeri, S. Peacock, M. D. McDonough, W. B. DeMartini, and J. Shook
Clinical Experience with MRI-Guided Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., June 1, 2005; 184(6): 1782 - 1787.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. D. Lehman and T. Aikawa
MR-guided Vacuum-assisted Breast Biopsy: Accuracy of Targeting and Success in Sampling in a Phantom Model
Radiology, September 1, 2004; 232(3): 911 - 914.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman
Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy
Radiology, September 1, 2004; 232(3): 897 - 903.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. C. Foster, M. A. Helvie, N. E. Gregory, M. Rebner, A. V. Nees, and C. Paramagul
Lobular Carcinoma in Situ or Atypical Lobular Hyperplasia at Core-Needle Biopsy: Is Excisional Biopsy Necessary?
Radiology, June 1, 2004; 231(3): 813 - 819.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. S. Burnside, D. L. Rubin, R. D. Shachter, R. E. Sohlich, and E. A. Sickles
A Probabilistic Expert System That Provides Automated Mammographic-Histologic Correlation: Initial Experience
Am. J. Roentgenol., February 1, 2004; 182(2): 481 - 488.
[Abstract] [Full Text] [PDF]


Home page
INT J SURG PATHOLHome page
S. Shousha
Issues in the Interpretation of Breast Core Biopsies
International Journal of Surgical Pathology, July 1, 2003; 11(3): 167 - 176.
[Abstract] [PDF]


Home page
Am. J. Roentgenol.Home page
L. E. Philpotts, R. J. Hooley, and C. H. Lee
Comparison of Automated Versus Vacuum-Assisted Biopsy Methods for Sonographically Guided Core Biopsy of the Breast
Am. J. Roentgenol., February 1, 2003; 180(2): 347 - 351.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman
Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study
Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. M. Chen, B. G. Haffty, and C. H. Lee
Local Recurrence of Breast Cancer after Breast Conservation Therapy in Patients Examined by Means of Stereotactic Core-Needle Biopsy
Radiology, December 1, 2002; 225(3): 707 - 712.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
M. B. Mainiero, I. F. Gareen, C. E. Bird, W. Smith, C. Cobb, and B. Schepps
Preferential Use of Sonographically Guided Biopsy to Minimize Patient Discomfort and Procedure Time in a Percutaneous Image-Guided Breast Biopsy Program
J. Ultrasound Med., November 1, 2002; 21(11): 1221 - 1226.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. J. Brenner, R. J. Jackman, S. H. Parker, W. P. Evans III, L. Philpotts, B. M. Deutch, M. C. Lechner, D. Lehrer, P. Sylvan, R. Hunt, et al.
Percutaneous Core Needle Biopsy of Radial Scars of the Breast: When Is Excision Necessary?
Am. J. Roentgenol., November 1, 2002; 179(5): 1179 - 1184.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, J. B. Kaplan, E. A. Morris, A. F. Abramson, J. H. Menell, and D. D. Dershaw
To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy?
Am. J. Roentgenol., September 1, 2002; 179(3): 679 - 683.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Georgian-Smith, C. D'Orsi, E. Morris, C. F. Clark Jr., E. Liberty, and C. D. Lehman
Stereotactic Biopsy of the Breast Using an Upright Unit, a Vacuum-Suction Needle, and a Lateral Arm-Support System
Am. J. Roentgenol., April 1, 2002; 178(4): 1017 - 1024.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. A. Perez-Fuentes, I. R. Longobardi, V. F. Acosta, C. E. Marin, and L. Liberman
Sonographically Guided Directional Vacuum-Assisted Breast Biopsy: Preliminary Experience in Venezuela
Am. J. Roentgenol., December 1, 2001; 177(6): 1459 - 1463.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. D. Lehman, H. J. Sieler-Gutierrez, and D. Georgian-Smith
Lateral Approach Biopsy Adapter: Accuracy on an Upright Unit in a Turkey Breast Model
Am. J. Roentgenol., October 1, 2001; 177(4): 897 - 899.
[Full Text] [PDF]


Home page
RadiologyHome page
R. F. Brem, J. M. Schoonjans, S. N. Goodman, A. Nolten, F. B. Askin, and O. M. B. Gatewood
Nonpalpable Breast Cancer: Percutaneous Diagnosis with 11- and 8-gauge Stereotactic Vacuum-assisted Biopsy Devices
Radiology, June 1, 2001; 219(3): 793 - 796.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, C. L. Benton, D. D. Dershaw, A. F. Abramson, L. R. LaTrenta, and E. A. Morris
Learning Curve for Stereotactic Breast Biopsy: How Many Cases Are Enough?
Am. J. Roentgenol., March 1, 2001; 176(3): 721 - 727.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
W. A. Berg, H. E. Mrose, and O. B. Ioffe
Atypical Lobular Hyperplasia or Lobular Carcinoma in Situ at Core-Needle Breast Biopsy
Radiology, February 1, 2001; 218(2): 503 - 509.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
M. L. R. Darling, D. N. Smith, S. C. Lester, C. Kaelin, D.-L. G. Selland, C. M. Denison, P. J. DiPiro, D. I. Rose, E. Rhei, and J. E. Meyer
Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy: Results of Surgical Excision
Am. J. Roentgenol., November 1, 2000; 175(5): 1341 - 1346.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, L. A. Ernberg, A. Heerdt, M. F. Zakowski, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and D. D. Dershaw
Palpable Breast Masses: Is There a Role for Percutaneous Imaging-Guided Core Biopsy?
Am. J. Roentgenol., September 1, 2000; 175(3): 779 - 787.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. E. Philpotts, N. A. Shaheen, K. S. Jain, D. Carter, and C. H. Lee
Uncommon High-Risk Lesions of the Breast Diagnosed at Stereotactic Core-Needle Biopsy: Clinical Importance
Radiology, September 1, 2000; 216(3): 831 - 837.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
L. Liberman and M. P. Sama
Cost-Effectiveness of Stereotactic 11-Gauge Directional Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., July 1, 2000; 175(1): 53 - 58.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman
Percutaneous Imaging-Guided Core Breast Biopsy: State of the Art at the Millennium
Am. J. Roentgenol., May 1, 2000; 174(5): 1191 - 1199.
[Full Text] [PDF]


Home page
RadiologyHome page
W. A. Berg, C. L. Arnoldus, E. Teferra, and M. Bhargavan
Biopsy of Amorphous Breast Calcifications: Pathologic Outcome and Yield at Stereotactic Biopsy
Radiology, November 1, 2001; 221(2): 495 - 503.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Roentgen Ray Society.