American Journal of Roentgenology, Vol 172, 1181-1184, Copyright © 1999 by American Roentgen Ray Society
ARTICLES |
L Pysher and C Harlow
Centura Health System/St. Thomas More Hospital, Canon City, CO 81212, USA.
OBJECTIVE: Our study was a practice audit to evaluate the feasibility of using low-cost, consumer-oriented computer hardware and software to perform after-hours teleradiology consisting predominantly of CT images. MATERIALS AND METHODS: We performed a prospective study of 137 consecutive emergent CT scans of the head obtained after business hours. The scans were digitized using a consumer-oriented, low-cost flatbed scanner and sent to on-call radiologists for interpretation. Preliminary reports were then telephoned to the referring physician. Another radiologist who was unaware of the preliminary report evaluated the hard-copy images. RESULTS: Combining cases with minor discrepancies and those of complete agreement, we found a 96% concordance. Five major discrepancies (4%) were found. No adverse outcomes resulted. Discrepancies were caused by interobserver variation rather than by the quality of the digitized images. CONCLUSION: Our results support the use of consumer-oriented, low-cost computer hardware and software for emergent teleradiology in which most of the transmitted studies consist of CT images of the head.
This article has been cited by other articles:
![]() |
W. K. Erly, W. G. Berger, E. Krupinski, J. F. Seeger, and J. A. Guisto Radiology Resident Evaluation of Head CT Scan Orders in the Emergency Department AJNR Am. J. Neuroradiol., January 1, 2002; 23(1): 103 - 107. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |