American Journal of Roentgenology, Vol 173, 275-278, Copyright © 1999 by American Roentgen Ray Society
ARTICLES |
WF Good, JH Sumkin, N Dash, CM Johns, ML Zuley, HE Rockette and D Gur
Department of Radiology, University of Pittsburgh, PA 15261, USA.
OBJECTIVE: To evaluate observer sensitivity to small differences in image presentation, a multipoint rank-order experiment was used to identify small differences or trends in observations. MATERIALS AND METHODS: Ten observers were presented with 50 sets of breast images that had been compressed at five different levels. Each set contained six images ranging from noncompressed to approximately 101:1 compression. Observers were asked to review all images of a case side by side and rank order the quality of each to enable determination of the presence or absence of masses and clustered microcalcifications. RESULTS: As a group, observers were able to detect small differences among the images, even at the lower compression levels (p < .001). As compression levels and image degradation increased, the ability to identify differences between different modes also increased. Large observer variability in discrimination ability was observed. CONCLUSION: Multipoint rank ordering of images viewed side by side can be an efficient method to identify small differences in image presentation. This approach to image ranking could be used to rule out or confirm the need for objective observer performance-type studies.
This article has been cited by other articles:
![]() |
J. G. Ravenel, E. M. Scalzetti, W. Huda, and W. Garrisi Radiation Exposure and Image Quality in Chest CT Examinations Am. J. Roentgenol., August 1, 2001; 177(2): 279 - 284. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. J. Weissman, J. A. Panza, J. F. Tighe Jr., S. T. Perras, H. Kushner, and J. S. Gottdiener Specificity of Doppler echocardiography for the assessment of changes in valvular regurgitation: comparison of side-by-side versus serial interpretation J. Am. Coll. Cardiol., May 1, 2001; 37(6): 1614 - 1621. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. F. Good, J. H. Sumkin, M. Ganott, L. Hardesty, B. Holbert, C. M. Johns, and A. H. Klym Detection of Masses and Clustered Microcalcifications on Data Compressed Mammograms: An Observer Performance Study Am. J. Roentgenol., December 1, 2000; 175(6): 1573 - 1576. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Sivaramakrishna, N. A. Obuchowski, W. A. Chilcote, G. Cardenosa, and K. A. Powell Comparing the Performance of Mammographic Enhancement Algorithms: A Preference Study Am. J. Roentgenol., July 1, 2000; 175(1): 45 - 51. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |