AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shellock, F. G.
Right arrow Articles by Shellock, V. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shellock, F. G.
Right arrow Articles by Shellock, V. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 173, 543-547, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

Metallic stents: evaluation of MR imaging safety

FG Shellock and VJ Shellock
Department of Radiology, School of Medicine, University of Southern California, Los Angeles 90036, USA.

OBJECTIVE: The objective of our investigation was to evaluate safety during MR imaging (i.e., magnetic field interactions, heating, and artifacts) for metallic stents. MATERIALS AND METHODS: Different types of metallic stents were tested for magnetic field interactions, heating, and artifacts using a 1.5-T MR system. Magnetic field-related translational attraction and torque were assessed using previously described techniques. Heating was evaluated using an infrared thermometer to record temperatures immediately before and after performing MR imaging using a whole-body-averaged specific absorption rate of 1.3 W/kg. Artifacts were assessed by placing the stents inside a fluid-filled phantom and performing MR imaging using fast spoiled gradient-echo and T1-weighted spin-echo pulse sequences. RESULTS: For the 10 different stents evaluated, we found no magnetic field interactions. the highest temperature change was < or = +0.3 degrees C, and the artifacts involved signal voids that would not create diagnostic problems as long as the area of interest was not positioned exactly where a particular stent was located. CONCLUSION: The findings of the safety tests indicated that the 10 different metallic stents would be safe for patients undergoing MR imaging procedures using MR systems with static magnetic fields of 1.5 T or less.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
CirculationHome page
G. N. Levine, A. S. Gomes, A. E. Arai, D. A. Bluemke, S. D. Flamm, E. Kanal, W. J. Manning, E. T. Martin, J. M. Smith, N. Wilke, et al.
Safety of Magnetic Resonance Imaging in Patients With Cardiovascular Devices: An American Heart Association Scientific Statement From the Committee on Diagnostic and Interventional Cardiac Catheterization, Council on Clinical Cardiology, and the Council on Cardiovascular Radiology and Intervention: Endorsed by the American College of Cardiology Foundation, the North American Society for Cardiac Imaging, and the Society for Cardiovascular Magnetic Resonance
Circulation, December 11, 2007; 116(24): 2878 - 2891.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
A. N. Raval, J. D. Telep, M. A. Guttman, C. Ozturk, M. Jones, R. B. Thompson, V. J. Wright, W. H. Schenke, R. DeSilva, R. J. Aviles, et al.
Real-Time Magnetic Resonance Imaging-Guided Stenting of Aortic Coarctation With Commercially Available Catheter Devices in Swine
Circulation, August 2, 2005; 112(5): 699 - 706.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. G. Shellock and J. V. Crues
MR Procedures: Biologic Effects, Safety, and Patient Care
Radiology, September 1, 2004; 232(3): 635 - 652.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
R. C. Gaba, R. C. Carlos, W. J. Weadock, G. P. Reddy, M. B. Sneider, and P. N. Cascade
Cardiovascular MR Imaging: Technique Optimization and Detection of Disease in Clinical Practice
RadioGraphics, November 1, 2002; 22(6): e6 - e6.
[Abstract] [Full Text]


Home page
Am. J. Roentgenol.Home page
E. M. Merkle, S. Klein, S. C. Kramer, and C. Wisianowsky
MR Angiographic Findings in Patients with Aortic Endoprostheses
Am. J. Roentgenol., March 1, 2002; 178(3): 641 - 648.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
E. M. Merkle, D. T. Boll, H. Weidenbach, H.-J. Brambs, and A. Gabelmann
Ability of MR Cholangiography to Reveal Stent Position and Luminal Diameter in Patients with Biliary Endoprostheses: In Vitro Measurements and In Vivo Results in 30 Patients
Am. J. Roentgenol., April 1, 2001; 176(4): 913 - 918.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Roentgen Ray Society.