AJR ARRS Member Benefits
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Brady, P. S.
Right arrow Articles by Dolmatch, B. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Brady, P. S.
Right arrow Articles by Dolmatch, B. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

American Journal of Roentgenology, Vol 173, 1023-1027, Copyright © 1999 by American Roentgen Ray Society


ARTICLES

Efficacy of percutaneous fibrin sheath stripping in restoring patency of tunneled hemodialysis catheters

PS Brady, LD Spence, A Levitin, CT Mickolich and BL Dolmatch
Department of Radiology, Cleveland Clinic Foundation, OH 44195, USA.

OBJECTIVE: Our objective was to determine the effectiveness of percutaneous fibrin sheath stripping as a method of restoring function to failing tunneled hemodialysis catheters. SUBJECTS AND METHODS: A total of 131 percutaneous fibrin sheath stripping procedures were performed on 100 failing tunneled hemodialysis catheters in 91 patients. Only the initial stripping procedure of the first catheter inserted in each patient was included for analysis. Patients were excluded if an additional cause of catheter failure was noted at the time of percutaneous fibrin stripping. Failure of the hemodialysis catheter was defined as inability to sustain an average blood flow rate of 250 ml/min or more in a hemodialysis session. Patients were followed up until the time of catheter failure, catheter removal, or a second stripping. Poststripping primary patency and complication rates were determined. RESULTS: The technical success of the procedure was 95.6%. Median follow-up was 16 weeks (range, 0-128 weeks). The overall median duration of primary patency after the first stripping was 89 days (3 months). No statistically significant difference in primary patency rates was seen between patients who underwent fibrin sheath demonstration by contrast injection and those who did not (p = .71). Female patients were statistically more likely to have catheter failure after catheter stripping than were male patients (p = .02). The route of catheter insertion did not significantly influence poststripping patency rates. No complications were associated with the procedure. CONCLUSION: Percutaneous fibrin sheath stripping is a safe, effective method of restoring patency to failing hemodialysis catheters when the failure is due to fibrin sheath formation and other causes are excluded.
Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Nephrol Dial TransplantHome page
A. S. Reddy, E. V. Lang, J. Cutts, S. Loh, and M. P. Rosen
Fibrin sheath removal from central venous catheters: an internal snare manoeuvre
Nephrol. Dial. Transplant., June 1, 2007; 22(6): 1762 - 1765.
[Abstract] [Full Text] [PDF]


Home page
Nephrol Dial TransplantHome page
F. Ewing, D. Patel, A. Petherick, R. Winney, and K. McBride
Radiological placement of the AshSplit haemodialysis catheter: a prospective analysis of outcome and complications
Nephrol. Dial. Transplant., April 1, 2002; 17(4): 614 - 619.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 1999 by the American Roentgen Ray Society.