AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Loubeyre, P.
Right arrow Articles by Minh, V. A. T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Loubeyre, P.
Right arrow Articles by Minh, V. A. T.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2000; 174:783-787
© American Roentgen Ray Society


Using Thoracic Helical CT to Assess Iodine Concentration in a Small Volume of Nonionic Contrast Medium During Vascular Opacification

A Prospective Study

Pierre Loubeyre1, Isabelle Debaro1, Chantal Nemoz2 and Van André Tran Minh1

1 Service de Radiologie du Centre Hospitalier Lyon Sud, EA 643, Chemin du Grand Revoyet, 69495 Pierre-Benite Cedex, France.
2 Unité de Pharmacologie Clinique, Université Claude-Bernard Lyon 1.8, Ave. Rockefeller, 69373 Lyon, Cedex 08, France.

OBJECTIVE. The goal of the study was to assess whether, using thoracic helical CT, diagnostic mediastinal and hilar vascular enhancement can be obtained with a small amount of nonionic contrast material (80 ml) injected at a relatively slow rate (2 ml/sec).

SUBJECTS AND METHODS. One hundred twenty patients (60 in their fourth decade malignancies of life and 60 in their seventh decade of life) referred for contrast-enhanced thoracic CT for malignancies or infections prospectively entered the study. They were randomly assigned to be given one of three iodine concentrations of a nonionic contrast material: 250 mg/ml (I250), 300 mg/ml (I300), and 350 mg/ml (I350). Two radiologists independently graded perivenous artifacts and arterial enhancement of mediastinal and hilar vessels on a 4-point scale: 1, poor; 2, fair; 3, good; and 4, excellent. Measurements of arterial attenuation values (quantitative assessment) were obtained on the aorta and pulmonary artery.

RESULTS. Mean scores were equal to or greater than 3 for all vessels only using I350. The higher the iodine concentration was, the higher the mean score, but there was a statistically significant difference only between scores obtained with I350 and those obtained with I300 or I250. Mean scores were higher for the patients in their seventh decade of life than those in their fourth decade; however, there was no statistically significant difference between scores of the two decade groups. We found a highly significant statistical relationship between scores and arterial attenuation values.

CONCLUSION. During contrast-enhanced helical CT examinations for general thoracic evaluations, good opacification of central vascular structures is obtained with a low volume of high iodine concentration nonionic contrast medium.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
V. D. Raptopoulos, P. B. Boiselle, N. Michailidis, J. Handwerker, A. Sabir, J. A. Edlow, I. Pedrosa, and J. B. Kruskal
MDCT Angiography of Acute Chest Pain: Evaluation of ECG-Gated and Nongated Techniques
Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S346 - S356.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Awai, A. Hatcho, Y. Nakayama, S. Kusunoki, D. Liu, M. Hatemura, Y. Funama, M. Denbo, N. Sato, and Y. Yamashita
Simulation of Aortic Peak Enhancement on MDCT Using a Contrast Material Flow Phantom: Feasibility Study
Am. J. Roentgenol., February 1, 2006; 186(2): 379 - 385.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. Loubeyre, I. Debard, C. Nemoz, and V. A. T. Minh
High Opacification of Hilar Pulmonary Vessels with a Small Amount of Nonionic Contrast Medium for General Thoracic CT: A Prospective Study
Am. J. Roentgenol., June 1, 2002; 178(6): 1377 - 1381.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Roentgen Ray Society.