AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Graf, B.
Right arrow Articles by Fiedler, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Graf, B.
Right arrow Articles by Fiedler, V.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2000; 174:1067-1074
© American Roentgen Ray Society


IK Versus 2K Monitor

A Clinical Alternative Free-Response Receiver Operating Characteristic Study of Observer Performance Using Pulmonary Nodules

B. Graf1,2, U. Simon3, F. Eickmeyer1 and V. Fiedler1

1 Klinikum Krefeld, Institute of Diagnostic Radiology, Lutherplatz 40, 47805 Krefeld, Germany.
2 Present address: Siemens AG, Medical Engineering, Völklinger Str. 2, 40219 Düsseldorf, Germany
3 German National Research Center for Information Technology (GMD), Institute for Applied Information Technology, Schloss Birlinghoven, 53754 Sankt Augustin, Germany.

OBJECTIVE. The aim of this study was to investigate whether and how observer performance in detecting pulmonary nodules is influenced by the use of 1K and 2K monitors with and without voluntary postprocessing.

MATERIALS AND METHODS. The study was conducted with clinical digital chest radiographs of 48 patients. CT images of the same patient group served as the gold standard. Data on four different monitor conditions (1K overview, 2K overview, 1K with postprocessing, and 2K with postprocessing) were collected using a 6-point confidence-rating scale and interpreted with an alternative free-response receiver operating characteristic.

RESULTS. When magnification and window settings were applied on the 1K monitor at the expense of an increased interpretation time, observer performance with the 1K monitor was not significantly different from that with the 2K monitor. A significant difference only occurred between the 1K monitor postprocessing condition and the 1K monitor overview condition.

CONCLUSION. Considering diagnostic accuracy, the 1K monitor is sufficient for the detection of pulmonary nodules, provided that postprocessing options—especially magnification—are applied. Further comparative monitor studies on the detectability of other abnormalities (e.g., fine interstitial structures) need to be performed.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
C. Balassy, M. Prokop, M. Weber, J. Sailer, C. J. Herold, and C. Schaefer-Prokop
Flat-Panel Display (LCD) Versus High-Resolution Gray-Scale Display (CRT) for Chest Radiography: An Observer Preference Study
Am. J. Roentgenol., March 1, 2005; 184(3): 752 - 756.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Roentgen Ray Society.