AJR Customized AJR reprints in quantities as low as 100!
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wever, J. J.
Right arrow Articles by Mali, W. P. Th. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wever, J. J.
Right arrow Articles by Mali, W. P. Th. M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2000; 175:1279-1282
© American Roentgen Ray Society


Inter- and Intraobserver Variability of CT Measurements Obtained After Endovascular Repair of Abdominal Aortic Aneurysms

J. J. Wever1, J. D. Blankensteijn1, J. C. van Rijn1, I. A. M. J. Broeders1, B. C. Eikelboom1 and W. P. Th. M. Mali2

1 Department of Vascular Surgery, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.
2 Department of Radiology, University Medical Center Utrecht, 3584 CX Utrecht, The Netherlands.

OBJECTIVE. Important decisions are made on the basis of CT angiographic measurements of aneurysm size obtained after endovascular abdominal aortic aneurysm repair; however, little is known about the variability of these measurements. We evaluated the variability of CT angiographic measurements of aneurysm size obtained after endovascular abdominal aortic aneurysm repair.

MATERIALS AND METHODS. Thirty CT angiographic data sets were randomly chosen from 91 sets, including preoperative, postoperative, and follow-up CT images. All images were obtained according to a standardized acquisition protocol. On a workstation, three parameters were measured: maximum aneurysm diameter, maximum aneurysm cross-sectional area, and aneurysm volume. All data sets were measured twice by two investigators in a random order. The difference of each pair of measurements was plotted against the mean value. The mean difference and its standard deviation were calculated with a repeatability coefficient.

RESULTS. The intraobserver repeatability coefficient for observer 1 was 3.8 mm for diameter, 201.7 mm2 for cross-sectional area, and 5.6 mL for volume. For observer 2, these figures were 3.0 mm, 219.0 mm2, and 8.1 mL, respectively. The interobserver repeatability coefficients were 3.9 mm, 236.2 mm2, and 10.3 mL.

CONCLUSION. Determination of the repeatability coefficient of aneurysm size measurements obtained after endovascular abdominal aortic aneurysm repair provides a good description of precision.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
S. W. Stavropoulos and S. R. Charagundla
Imaging Techniques for Detection and Management of Endoleaks after Endovascular Aortic Aneurysm Repair
Radiology, June 1, 2007; 243(3): 641 - 655.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Schoder, F. Cartes-Zumelzu, M. Grabenwoger, M. Cejna, M. Funovics, C. G. Krenn, D. Hutschala, F. Wolf, S. Thurnher, G. Kretschmer, et al.
Elective Endovascular Stent-Graft Repair of Atherosclerotic Thoracic Aortic Aneurysms:Clinical Results and Midterm Follow-Up
Am. J. Roentgenol., March 1, 2003; 180(3): 709 - 715.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Roentgen Ray Society.