AJR Join ARRS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Darling, M. L. R.
Right arrow Articles by Meyer, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Darling, M. L. R.
Right arrow Articles by Meyer, J. E.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2000; 175:1341-1346
© American Roentgen Ray Society


Atypical Ductal Hyperplasia and Ductal Carcinoma In Situ as Revealed by Large-Core Needle Breast Biopsy

Results of Surgical Excision

Marla L. Rosenfield Darling1, Darrell N. Smith1, Susan C. Lester2, Carolyn Kaelin3, Donna-Lee G. Selland1, Christine M. Denison1, Pamela J. DiPiro1, David I. Rose1, Esther Rhei3 and Jack E. Meyer1

1 Department of Radiology, Brigham and Women's Hospital, 75 Francis St., Boston, MA 02115.
2 Department of Pathology, Brigham and Women's Hospital, Boston, MA 02115.
3 Department of Surgery, Brigham and Women's Hospital, Boston, MA 02115.

OBJECTIVE. This investigation compares the frequency of histologic underestimation of breast carcinoma that occurs when a large-core needle biopsy reveals atypical ductal hyperplasia or ductal carcinoma in situ with the automated 14-gauge needle, the 14-gauge directional vacuum-assisted biopsy device, and the 11-gauge directional vacuum-assisted biopsy device.

SUBJECTS AND METHODS. Evaluation of 428 large-core needle biopsies yielding atypical ductal hyperplasia (139 lesions) or ductal carcinoma in situ (289 lesions) was performed. The results of subsequent surgical excision were retrospectively compared with the needle biopsy results.

RESULTS. For lesions initially diagnosed as ductal carcinoma in situ, underestimation of invasive ductal carcinoma was significantly less frequent using the 11-gauge directional vacuum-assisted biopsy device when compared with the automated 14-gauge needle (10% versus 21%, p < 0.05) but was not significantly less frequent when compared with the 14-gauge directional vacuum-assisted device (10% versus 17%, p > 0.1). For lesions diagnosed initially as atypical ductal hyperplasia, underestimation of ductal carcinoma in situ and invasive ductal carcinoma was significantly less frequent using the 11-gauge directional vacuum-assisted biopsy device compared with the 14-gauge directional vacuum-assisted device (19% versus 39%, p = 0.025) and with the automated 14-gauge needle (19% versus 44%, p = 0.01).

CONCLUSION. The frequency of histologic underestimation of breast carcinoma in lesions initially diagnosed as atypical ductal hyperplasia or ductal carcinoma in situ using large-core needle biopsy is substantially lower with the 11-gauge directional vacuum-assisted device than with the automated 14-gauge needle and with the 14-gauge directional vacuum-assisted device.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
R. F. Brem, M. C. Lechner, R. J. Jackman, J. A. Rapelyea, W. P. Evans, L. E. Philpotts, J. Hargreaves, and S. Wasden
Lobular Neoplasia at Percutaneous Breast Biopsy: Variables Associated with Carcinoma at Surgical Excision
Am. J. Roentgenol., March 1, 2008; 190(3): 637 - 641.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. P. Lourenco, M. B. Mainiero, E. Lazarus, D. Giri, and B. Schepps
Stereotactic Breast Biopsy: Comparison of Histologic Underestimation Rates with 11- and 9-Gauge Vacuum-Assisted Breast Biopsy
Am. J. Roentgenol., November 1, 2007; 189(5): W275 - W279.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
J. C. Boughey, R. J. Gonzalez, E. Bonner, and H. M. Kuerer
Current Treatment and Clinical Trial Developments for Ductal Carcinoma In Situ of the Breast
Oncologist, November 1, 2007; 12(11): 1276 - 1287.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. Pandey, M. J. Kornstein, W. Shank, and E. S. de Paredes
Columnar Cell Lesions of the Breast: Mammographic Findings with Histopathologic Correlation
RadioGraphics, October 1, 2007; 27(suppl_1): S79 - S89.
[Abstract] [Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
V. Sohn, Z. Arthurs, G. Herbert, J. Keylock, J. Perry, M. Eckert, D. Fellabaum, D. Smith, and T. Brown
Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle
Ann. Surg. Oncol., September 1, 2007; 14(9): 2497 - 2501.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. R. Margolin, L. Kaufman, R. P. Jacobs, S. R. Denny, and J. D. Schrumpf
Stereotactic Core Breast Biopsy of Malignant Calcifications: Diagnostic Yield of Cores with and Cores without Calcifications on Specimen Radiographs
Radiology, October 1, 2004; 233(1): 251 - 254.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman
Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy
Radiology, September 1, 2004; 232(3): 897 - 903.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. C. Foster, M. A. Helvie, N. E. Gregory, M. Rebner, A. V. Nees, and C. Paramagul
Lobular Carcinoma in Situ or Atypical Lobular Hyperplasia at Core-Needle Biopsy: Is Excisional Biopsy Necessary?
Radiology, June 1, 2004; 231(3): 813 - 819.
[Abstract] [Full Text] [PDF]


Home page
NEJMHome page
H. J. Burstein, K. Polyak, J. S. Wong, S. C. Lester, and C. M. Kaelin
Ductal Carcinoma in Situ of the Breast
N. Engl. J. Med., April 1, 2004; 350(14): 1430 - 1441.
[Full Text] [PDF]


Home page
Ann. Surg. Oncol.Home page
L. E. Hoorntje, M. E. I. Schipper, P. H. M. Peeters, F. Bellot, R. K. Storm, and I. H. M. Borel Rinkes
The Finding of Invasive Cancer After a Preoperative Diagnosis of Ductal Carcinoma-In-Situ: Causes of Ductal Carcinoma-In-Situ Underestimates With Stereotactic 14-Gauge Needle Biopsy
Ann. Surg. Oncol., August 1, 2003; 10(7): 748 - 753.
[Abstract] [Full Text] [PDF]


Home page
INT J SURG PATHOLHome page
S. Shousha
Issues in the Interpretation of Breast Core Biopsies
International Journal of Surgical Pathology, July 1, 2003; 11(3): 167 - 176.
[Abstract] [PDF]


Home page
RadiologyHome page
S. Huber, M. Wagner, M. Medl, and H. Czembirek
Benign Breast Lesions: Minimally Invasive Vacuum-assisted Biopsy with 11-Gauge Needles—Patient Acceptance and Effect on Follow-up Imaging Findings
Radiology, March 1, 2003; 226(3): 783 - 790.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
J. W. Jakub, S. Pendas, and D. S. Reintgen
Current Status of Sentinel Lymph Node Mapping and Biopsy: Facts and Controversies
Oncologist, February 1, 2003; 8(1): 59 - 68.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, J. B. Kaplan, E. A. Morris, A. F. Abramson, J. H. Menell, and D. D. Dershaw
To Excise or To Sample the Mammographic Target: What Is the Goal of Stereotactic II-Gauge Vacuum-Assisted Breast Biopsy?
Am. J. Roentgenol., September 1, 2002; 179(3): 679 - 683.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman, R. L. Birdwell, and D. M. Ikeda
Atypical Ductal Hyperplasia: Can Some Lesions Be Defined as Probably Benign after Stereotactic 11-gauge Vacuum-assisted Biopsy, Eliminating the Recommendation for Surgical Excision?
Radiology, August 1, 2002; 224(2): 548 - 554.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Georgian-Smith, C. D'Orsi, E. Morris, C. F. Clark Jr., E. Liberty, and C. D. Lehman
Stereotactic Biopsy of the Breast Using an Upright Unit, a Vacuum-Suction Needle, and a Lateral Arm-Support System
Am. J. Roentgenol., April 1, 2002; 178(4): 1017 - 1024.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, S. L. Goodstine, D. D. Dershaw, E. A. Morris, L. R. LaTrenta, A. F. Abramson, and K. J. V. Zee
One Operation After Percutaneous Diagnosis of Nonpalpable Breast Cancer: Frequency and Associated Factors
Am. J. Roentgenol., March 1, 2002; 178(3): 673 - 679.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. A. Perez-Fuentes, I. R. Longobardi, V. F. Acosta, C. E. Marin, and L. Liberman
Sonographically Guided Directional Vacuum-Assisted Breast Biopsy: Preliminary Experience in Venezuela
Am. J. Roentgenol., December 1, 2001; 177(6): 1459 - 1463.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, C. A. Gougoutas, M. F. Zakowski, L. R. LaTrenta, A. F. Abramson, E. A. Morris, and D. D. Dershaw
Calcifications Highly Suggestive of Malignancy: Comparison of Breast Biopsy Methods
Am. J. Roentgenol., July 1, 2001; 177(1): 165 - 172.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. A. Guenin, M. L. R. Darling, D. N. Smith, and S. C. Lester
Less Is Not More in Stereotactic Biopsy
Am. J. Roentgenol., July 1, 2001; 177(1): 250 - 251.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2000 by the American Roentgen Ray Society.