AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Herts, B. R.
Right arrow Articles by Pohlman, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Herts, B. R.
Right arrow Articles by Pohlman, B.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2001; 176:447-453
© American Roentgen Ray Society


Power Injection of Contrast Media Using Central Venous Catheters

Feasibility, Safety, and Efficacy

Brian R. Herts1, Charles M. O'Malley2, Susan L. Wirth1, Michael L. Lieber2 and Brad Pohlman3

1 Department of Radiology, Hb6, The Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH 44195.
2 Department of Biostatistics, The Cleveland Clinic Foundation, Cleveland, OH 44195.
3 Department of Hematology and Oncology, The Cleveland Clinic Foundation, Cleveland, OH 44195.

OBJECTIVE. This study evaluates the feasibility, safety, and efficacy of power-injecting IV contrast media through central venous catheters for CT examinations.

SUBJECTS AND METHODS. Two hundred ninety-five CT examinations were performed during an 18-month period in 225 patients with indwelling central venous catheters. Patients were randomized to power injection either through peripheral IV catheter or through central venous catheter. Feasibility was defined as the percentage of patients with contrast material injected successfully through the randomized access route. Safety was evaluated by comparing patients with complications. Efficacy was evaluated by comparing contrast enhancement of the thoracic aorta, pulmonary artery, abdominal aorta, and liver.

RESULTS. Two hundred nine patients had randomization data recorded. One hundred three (94%) of 109 patients were successfully injected through their indwelling catheter compared with 42 (42%) of 100 through a peripherally placed IV catheter (p < 0.001). After reassignment for unsuccessful access, 174 patients underwent central venous catheter injection, and 51, peripheral IV catheter injection. No statistically significant difference was noted in the complications between the central venous catheter and peripheral IV catheter groups. Enhancement was greater in the thoracic aorta, pulmonary artery, and liver for the peripheral IV catheter group (p < 0.03).

CONCLUSION. Power injection of contrast media through central venous catheters for CT examinations is feasible and safe when set hospital guidelines and injection protocols are followed. This technique provides an acceptable alternative in patients without adequate peripheral IV access when bolus contrast enhancement is desired.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. T. Bae, A. J. Shah, S. S. Shang, J. H. Wang, S. Chang, M. Kanematsu, and C. F. Hildebolt
Aortic and Hepatic Contrast Enhancement with Abdominal 64-MDCT in Pediatric Patients: Effect of Body Weight and Iodine Dose
Am. J. Roentgenol., November 1, 2008; 191(5): 1589 - 1594.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. F. Donnelly, J. Dickerson, and J. M. Racadio
Is Hand Injection of Central Venous Catheters for Contrast-Enhanced CT Safe in Children?
Am. J. Roentgenol., December 1, 2007; 189(6): 1530 - 1532.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. K. Rigsby, E. Gasber, R. Seshadri, C. Sullivan, M. Wyers, and T. Ben-Ami
Safety and Efficacy of Pressure-Limited Power Injection of Iodinated Contrast Medium Through Central Lines in Children
Am. J. Roentgenol., March 1, 2007; 188(3): 726 - 732.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P O'Sullivan, M Brown, B Hartnett, and J R Mayo
Central line pump infusion and large volume mediastinal contrast extravasation in CT
Br. J. Radiol., August 1, 2006; 79(944): e75 - e77.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
P. A. MILLER
Central venous access devices.
Radiol. Technol., March 1, 2006; 77(4): 297 - 305.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. C. Sanelli, M. Deshmukh, I. Ougorets, R. Caiati, and L. A. Heier
Safety and Feasibility of Using a Central Venous Catheter for Rapid Contrast Injection Rates
Am. J. Roentgenol., December 1, 2004; 183(6): 1829 - 1834.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Funaki
Central Venous Access: A Primer for the Diagnostic Radiologist
Am. J. Roentgenol., August 1, 2002; 179(2): 309 - 318.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.