AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Liberman, L.
Right arrow Articles by Morris, E. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Liberman, L.
Right arrow Articles by Morris, E. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2001; 176:721-727
© American Roentgen Ray Society


Learning Curve for Stereotactic Breast Biopsy

How Many Cases Are Enough?

Laura Liberman1, Catherine L. Benton, D. David Dershaw, Andrea F. Abramson, Linda R. LaTrenta and Elizabeth A. Morris

1 All authors: Breast Imaging Section, Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Ave., New York, NY 10021.

OBJECTIVE. The objective of this study was to evaluate the learning curve for stereotactic breast biopsy.

MATERIALS AND METHODS. Retrospective review was performed of 923 consecutive lesions that underwent stereotactic breast biopsy performed by one of six radiologists. Four hundred fourteen lesions had 14-gauge automated core biopsy, and 509 subsequent lesions had vacuum-assisted biopsy (14-gauge in 163 and 11-gauge in 346). Medical records were reviewed to determine the technical success rate and false-negative rate as a function of operator experience.

RESULTS. For 14-gauge automated core biopsy, a significantly lower technical success rate was seen for the first five cases of each radiologist than for subsequent cases (25/30 = 83.3% versus 366/384 = 95.3%, p < 0.02) and for the first 20 cases than for subsequent cases (90/100 = 90% versus 284/296 = 95.9%, p < 0.05). For 11-gauge vacuum-assisted biopsy, a significantly lower technical success rate was seen for the first five cases than for subsequent cases (17/20 = 85.0% versus 310/322 = 96.3%, p < 0.05) and for the first 15 cases than for subsequent cases (54/60 = 90.0% versus 273/283 = 96.5%, p = 0.03). The false-negative rate was higher for the first 15 cases compared with subsequent cases both for stereotactic 14-gauge automated core biopsy (4/31 = 12.9% versus 3/115 = 2.6%, p < 0.04) and for stereotactic 11-gauge vacuum-assisted biopsy (2/27 = 7.4% versus 0/85 = 0%, p < 0.06).

CONCLUSION. A learning curve exists for stereotactic breast biopsy. Significantly higher technical success rates and lower false-negative rates were observed after the first five to 20 cases for 14-gauge automated core biopsy and after the first five to 15 cases for 11-gauge vacuum-assisted biopsy. Even after a radiologist has experience with stereotactic biopsy, changes in equipment may result in a new learning curve.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. Larrison, A. DiBona, and D. E. Hogg
Low-Cost Phantom for Stereotactic Breast Biopsy Training
Am. J. Roentgenol., October 1, 2006; 187(4): 972 - 974.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman and J. Rodriguez-Soto
Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.
Radiology, April 1, 2006; 239(1): 61 - 70.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. C. Riedl, G. Pfarl, M. Memarsadeghi, T. Wagner, F. Fitzal, M. Rudas, and T. H. Helbich
Lesion Miss Rates and False-Negative Rates for 1115 Consecutive Cases of Stereotactically Guided Needle-localized Open Breast Biopsy with Long-term Follow-up
Radiology, December 1, 2005; 237(3): 847 - 853.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman
Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy
Radiology, September 1, 2004; 232(3): 897 - 903.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
G. Pfarl, T. H. Helbich, C. C. Riedl, T. Wagner, M. Gnant, M. Rudas, and L. Liberman
Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study
Am. J. Roentgenol., December 1, 2002; 179(6): 1503 - 1507.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, C. A. Gougoutas, M. F. Zakowski, L. R. LaTrenta, A. F. Abramson, E. A. Morris, and D. D. Dershaw
Calcifications Highly Suggestive of Malignancy: Comparison of Breast Biopsy Methods
Am. J. Roentgenol., July 1, 2001; 177(1): 165 - 172.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.