AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vernhet, H.
Right arrow Articles by Dauzat, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vernhet, H.
Right arrow Articles by Dauzat, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2001; 176:803-807
© American Roentgen Ray Society


Changes in Wall Mechanics After Endovascular Stenting in the Rabbit Aorta

Comparison of Three Stent Designs

Hélène Vernhet1, Roland Demaria1, Jean Marie Juan1, Marie Claire Oliva-Lauraire1, Jean Paul Sénac2 and Michel Dauzat1

1 Laboratory of Cardiovascular Physiology, Montpellier I University, Faculty of Medicine, Av. Kennedy, Nîmes F 30907, France.
2 Department of Thoracic and Cardiovascular Imaging, Montpellier University Hospital, 34295-Montpellier Cedex, France.

OBJECTIVE. The aim of this study was to evaluate changes in the wall mechanics of small-diameter arteries after endovascular placement of three different stents.

SUBJECTS AND METHODS. Five self-expandable stents (Wallstent), five balloon-expandable noncovered Palmaz stents, and three balloon-expandable covered stents (Jostent) were placed in the infrarenal aorta of 13 New Zealand white rabbits. Systolic blood pressure changes, blood-flow velocity, systolic diameter, and diameter changes were measured and used to calculate the diameter compliance, the distensibility coefficient, and the pulsatility index.

RESULTS. Compliance (10-3 mm kPa-1) was 75.3 ± 20.1 before stenting and reached 94.7 ± 42.2 upstream, 38.8 ± 14.2 at the stent level (p < 0.05), and 70.8 ± 23.2 downstream from the stent. Distensibility (10-3 kPa-1) was 24.3 ± 6.3 before stenting and reached 27.8 ± 10.3 upstream, 10.5 ± 4.4 at the stent level (p < 0.001), and 21.9 ± 8.6 downstream from the stent.

Compliance and distensibility were significantly lower at the stent level than upstream and downstream (p < 0.05). Aortic diameter increased significantly at the stent level from 3.11 ± 0.40 mm before to 3.76 ± 0.42 mm after stenting. No significant difference was found among the three stent designs for all the studied data.

CONCLUSION. Regardless of the three tested stent designs, endovascular stenting produces a significant decrease in arterial wall compliance of the rabbit aorta.