AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Juergens, K. U.
Right arrow Articles by Heindel, W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Juergens, K. U.
Right arrow Articles by Heindel, W.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2001; 176:1299-1303
© American Roentgen Ray Society


Three-Dimensional Contrast-Enhanced MR Angiography of Endovascular Covered Stents in Patients with Peripheral Arterial Occlusive Disease

Kai Uwe Juergens1, Bernd Tombach, Peter Reimer, Thomas Vestring and Walter Heindel

1 All authors: Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Str. 33, D-48129 Muenster, Germany.

OBJECTIVE. Three-dimensional contrast-enhanced MR angiography was performed to study MR characteristics of Hemobahn devices.

MATERIALS AND METHODS. Changes in endoluminal signal intensities and the precision of the endoluminal diameter measurement were investigated in phantom studies for different concentrations of gadopentetate dimeglumine. Before and after the Hemobahn devices had been implanted, 10 patients with peripheral arterial occlusive disease were examined on MR imaging and three-dimensional contrast-enhanced MR angiography.

RESULTS. Phantom experiments using three-dimensional MR angiography showed stent-related signal void as a dark ring in the axial image orientation, providing a precise delineation of the stent-vessel border (mean endoluminal diameter, 8.2 mm; SD, 0.6 mm). Changes in endoluminal signal intensity were evaluated quantitatively. Stent-related artifacts did not compromise diagnostic imaging quality. All Hemobahn devices were found to be patent without migration of an implanted graft. In one patient, an extensive perigraft reaction (edema and contrast-enhanced perivascular tissue) was postinterventionally detected on MR imaging and corresponded to clinically evident postimplantation symptoms.

CONCLUSION. Three-dimensional contrast-enhanced MR angiography is a suitable tool to follow up the implantation of Hemobahn devices and to detect intra- and extraluminal abnormalities.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
O W Hamer, I Borisch, C Paetzel, W R Nitz, J Seitz, S Feuerbach, and N Zorger
In vitro evaluation of stent patency and in-stent stenoses in 10 metallic stents using MR angiography
Br. J. Radiol., August 1, 2006; 79(944): 636 - 643.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
O. W. Hamer, T. Finkenzeller, I. Borisch, C. Paetzel, N. Zorger, S. Feuerbach, and W. Nitz
In Vivo Evaluation of Patency and In-Stent Stenoses After Implantation of Nitinol Stents in Iliac Arteries Using MR Angiography
Am. J. Roentgenol., November 1, 2005; 185(5): 1282 - 1288.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. D. Hagspiel, D. A. Leung, K. R. Nandalur, J. F. Angle, H. S. Dulai, D. J. Spinosa, A. H. Matsumoto, J. M. Christopher, H. Ahmed, and S. S. Berr
Contrast-Enhanced MR Angiography at 1.5 T After Implantation of Platinum Stents: In Vitro and In Vivo Comparison with Conventional Stent Designs
Am. J. Roentgenol., January 1, 2005; 184(1): 288 - 294.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Spuentrup, A. Ruebben, M. Stuber, R. W. Gunther, and A. Buecker
Metallic Renal Artery MR Imaging Stent: Artifact-free Lumen Visualization with Projection and Standard Renal MR Angiography
Radiology, June 1, 2003; 227(3): 897 - 902.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. Tello, K. R. Thomson, K. U. Juergens, B. Tombach, and P. Reimer
Contrast-Enhanced MR Angiography of Endovascular Stents: An Oversight in Citation?
Am. J. Roentgenol., December 1, 2001; 177 (6): 1483 - 1484.
[Full Text] [PDF]


Home page
CirculationHome page
A. Buecker, E. Spuentrup, A. Ruebben, and R. W. Gunther
Artifact-Free In-Stent Lumen Visualization by Standard Magnetic Resonance Angiography Using a New Metallic Magnetic Resonance Imaging Stent
Circulation, April 16, 2002; 105(15): 1772 - 1775.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.