AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wetzel, S. G.
Right arrow Articles by Rofsky, N. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wetzel, S. G.
Right arrow Articles by Rofsky, N. M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2001; 177:703-707
© American Roentgen Ray Society


Real-Time Interactive Duplex MR Measurements

Application in Neurovascular Imaging

Stephan G. Wetzel1, Vivian S. Lee1, Andrew G. S. Tan1, Oliver Heid2, Soonmee Cha1, Glyn Johnson1 and Neil M. Rofsky1,3

1 Department of Radiology, New York University Medical Center, 530 First Ave., HCC Basement-MRI, New York, NY 10016.
2 Siemens Medical Engineering, MRI Division, Karl-Schall-Str., 91052 Erlangen, Germany.
3 Present address: Magnetic Resonance Imaging, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Ave., Boston, MA 02215.

OBJECTIVE. Real-time interactive duplex MR imaging is a new phase-contrast MR imaging technique that enables the quantification and display of flow velocities in real time without the need for cardiac gating. We investigated the feasibility and reliability of the technique to assess hemodynamic information both in vitro and in vivo in the carotid arteries and in the venous sinuses.

SUBJECTS AND METHODS. Real-time interactive duplex MR measurements (TR/TE, 53/27; flip angle, 90°; encoding velocity, 100 or 150 cm/sec) were performed in vitro with a steady-flow phantom and in 10 healthy volunteers in whom common and internal carotid artery velocities were measured. In eight volunteers, velocity measurements were also performed in the superior sagittal sinus during both normal breathing and hyperventilation. Time—velocity plots were analyzed qualitatively and quantitatively and compared with findings from conventional segmented k-space phase-contrast MR imaging and Doppler sonography.

RESULTS. Velocity determinations for real-time duplex MR and conventional phase-contrast MR imaging showed an in vitro correlation of 0.99 and an in vivo correlation of 0.83 (carotid arteries) and 0.76 (venous sinus). Velocity measurements in the carotid arteries with real-time MR imaging were significantly lower than those obtained with conventional phase-contrast MR (averaged, 7.8%; p = 0.003) or sonography (23.7%, p < 0.001), likely because of volume averaging. Small but significant velocity changes occurring in the venous sinus during hyperventilation were reliably identified with both MR techniques.

CONCLUSION. Real-time interactive duplex MR imaging can be effectively applied in neurovascular imaging to obtain hemodynamic information.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadioGraphicsHome page
J. Lotz, C. Meier, A. Leppert, and M. Galanski
Cardiovascular Flow Measurement with Phase-Contrast MR Imaging: Basic Facts and Implementation
RadioGraphics, May 1, 2002; 22(3): 651 - 671.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.