|
|
||||||||
1 All authors: Department of Radiology, Rinku General Medical Center, 2-23 Rinku-orai-kita, Izumisano, Osaka 598-8577, Japan.
OBJECTIVE. The purpose of this study was to compare selenium-based digital radiography with high-resolution storage phosphor radiography for the detection of solitary pulmonary nodules without calcification.
MATERIALS AND METHODS. One hundred twenty-four patients underwent selenium-based digital radiography, high-resolution storage phosphor radiography, and chest CT for evaluation of pulmonary nodules. Thirty-one patients with pulmonary nodules smaller than 3 cm in diameter and 40 patients with normal lungs were selected for receiver operating characteristic curve analysis. Five board-certified radiologists who were unaware of the CT results independently reviewed each of the hard copies of selenium-based digital radiography and storage phosphor radiography, identified pulmonary nodules, and graded their confidence for the presence of each nodule. For each radiologist, we calculated the areas under the receiver operating characteristic curve (AUC) for selenium-based digital radiography and storage phosphor radiography.
RESULTS. The average performance of selenium-based digital radiography (AUC = 0.72) was higher than that of high-resolution storage phosphor radiography (AUC = 0.64), which is statistically significant (p <0.05).
CONCLUSION. Our results indicate that selenium-based digital radiography is superior to high-resolution storage phosphor radiography for detecting solitary pulmonary nodules without calcification.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
K. Bacher, P. Smeets, L. Vereecken, A. De Hauwere, P. Duyck, R. De Man, K. Verstraete, and H. Thierens Image quality and radiation dose on digital chest imaging: comparison of amorphous silicon and amorphous selenium flat-panel systems. Am. J. Roentgenol., September 1, 2006; 187(3): 630 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Ono, T Yoshitake, K Akahane, Y Yamada, T Maeda, M Kai, and T Kusama Comparison of a digital flat-panel versus screen-film, photofluorography and storage-phosphor systems by detection of simulated lung adenocarcinoma lesions using hard copy images Br. J. Radiol., October 1, 2005; 78(934): 922 - 927. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, M. V. Boot, and J. Geleijns Comparison of Eight Different Digital Chest Radiography Systems: Variation in Detection of Simulated Chest Disease Am. J. Roentgenol., August 1, 2005; 185(2): 339 - 346. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |