|
|
||||||||
1
Department of Radiology, Northwestern University Medical School, 676 N. St.
Clair, Ste. 800, Chicago, IL 60611.
2
Siemens Medical Systems, 448 E. Ontario, Ste. 700, Chicago, IL 60611.
3
University of Arizona Health Sciences Center, 1609 N. Warren, Bldg. 112,
Tucson, AZ 85724.
OBJECTIVE. The purpose of this study is to compare ultrashort TR, segmented trueFISP (fast imaging with steady-state precession) cine MR imaging with segmented FLASH (fast low-angle shot) cine MR imaging for the detection and characterization of congenital and acquired adult cardiac abnormalities.
SUBJECTS AND METHODS. Twenty-five patients with known or clinically suspected cardiac abnormalities were imaged on a 1.5-T scanner. Valve plane movies were obtained in patients with suspected valve morphology or function abnormalities or whose horizontal long-axis images showed jets. For each patient, three radiologists independently compared corresponding matched cine FLASH and trueFISP movies for image quality in evaluating anatomy and function of the great vessels and heart. Image quality was rated on a five-point scale, and data were analyzed using both a Wilcoxon's signed rank test and a repeated-measures analysis of variance.
RESULTS. Image quality ratings of trueFISP and FLASH showed a statistically significant difference (F = 58.67; df = 1, 72; p < 0.0001), with the average rating for the trueFISP images being significantly higher (mean rating, 4.1 ± 0.92) than that for the FLASH images (mean, 3.0 ± 1.0). However, valve architecture in the aortic valves appeared to be better visualized and was more easily measured in valve plane images with FLASH. No statistically significant differences among the ratings of the interpreters (F = 0.018; df = 2, 72; p = 0.9821) were evident, and, therefore, no suggestion of bias was indicated (F = 0.775; df = 1, 2; p = 0.4645). TrueFISP yielded the correct diagnosis prospectively in 13 (100%) of 13 patients, whereas FLASH yielded the correct diagnosis in 12 (92%) of 13 patients.
CONCLUSION. TrueFISP images depict morphologic and functional abnormalities with greater clarity and provide greater diagnostic confidence than FLASH imagesand in a fraction of the time. A specific exception is in the assessment of valve leaflet architecture and cross-sectional area calculation (i.e., bicuspid aortic valves); in these evaluations, FLASH maintains a complementary diagnostic imaging role.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
A. Crean Cardiovascular MR and CT in congenital heart disease Heart, December 1, 2007; 93(12): 1637 - 1647. [Full Text] [PDF] |
||||
![]() |
M. Fenchel, R. Saleh, H. Dinh, M. H. Lee, K. Nael, M. Krishnam, S. G. Ruehm, S. Miller, J. Child, and J. P. Finn Juvenile and Adult Congenital Heart Disease: Time-resolved 3D Contrast-enhanced MR Angiography Radiology, August 1, 2007; 244(2): 399 - 410. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. K. Mohrs, S. E. Petersen, T. Voigtlaender, J. Peters, B. Nowak, M. K. Heinemann, and H.-U. Kauczor Time-Resolved Contrast-Enhanced MR Angiography of the Thorax in Adults with Congenital Heart Disease Am. J. Roentgenol., October 1, 2006; 187(4): 1107 - 1114. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. M. Shea, D. S. Fieno, B. E. Schirf, X. Bi, J. Huang, R. A. Omary, and D. Li T2-prepared Steady-State Free Precession Blood Oxygen Level-Dependent MR Imaging of Myocardial Perfusion in a Dog Stenosis Model Radiology, August 1, 2005; 236(2): 503 - 509. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Baskaran, F. S. Pereles, E. J. Russell, S. A. Georganos, A. Shaibani, K. A. Spero, E. A. Krupinski, A. Zhang, and J. P. Finn Myelographic MR Imaging of the Cervical Spine with a 3D True Fast Imaging with Steady-State Precession Technique: Initial Experience Radiology, May 1, 2003; 227(2): 585 - 592. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. S. Pereles, R. M. McCarthy, V. Baskaran, J. C. Carr, V. Kapoor, E. A. Krupinski, and J. P. Finn Thoracic Aortic Dissection and Aneurysm: Evaluation with Nonenhanced True FISP MR Angiography in Less than 4 Minutes Radiology, April 1, 2002; 223(1): 270 - 274. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |