AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Zähringer, M.
Right arrow Articles by Lackner, K. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zähringer, M.
Right arrow Articles by Lackner, K. J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2001; 177:1397-1403
© American Roentgen Ray Society


Detection of Porcine Bone Lesions and Fissures

Comparing Digital Selenium, Digital Luminescence, and Analog Film-Screen Radiography

Markus Zähringer1, Barbara Krug1, Karl-F. Kamm2, Gernot Wassmer3, Martin Hellmich3, Guido Winnekendonk1, Jonas Andermahr4, Axel Goßmann1 and Klaus J. Lackner1

1 Department of Radiology, University of Cologne Medical School, University of Cologne, Kerpenerstr. 62, 50924 Cologne, Germany.
2 Philips Medical Systems, Röntgenstr. 24, 22335 Hamburg, Germany.
3 Department of Medical Statistics, Informatics and Epidemiology, University of Cologne Medical School, 50924 Cologne, Germany.
4 Department of Trauma, Hand and Reconstructive Surgery, University of Cologne Medical School, 50924 Cologne, Germany.

OBJECTIVE. The purpose of our study was to compare the diagnostic performance of a digital selenium detector (Thoravision) with that of analog film-screen systems and digital luminescence radiography in skeletal radiography for the detection of fissures and lesions in porcine bones.

MATERIALS AND METHODS. One hundred bones taken from domestic pigs (50 ribs and 50 femurs) were divided into two equal groups. Fissures and bone lesions were created in 50 bones and 50 served as controls. The bones were examined using film-screen systems, digital luminescence radiography, and digital selenium radiography at various doses. Digital selenium radiography exposure values were adapted to the image geometry differing from the reference methods with a detector focus distance of 2.15 m. Four radiologists independently evaluated image quality and detectability of fissures and lesions on a five-point scale of confidence. Statistical evaluation was based on receiver operating characteristic curve analysis.

RESULTS. Fissures and bone lesions were detected most reliably using the mammography film-screen system, but the difference in the results of the analog and digital reference images did not achieve statistical significance.

CONCLUSION. Compared with analog film-screen systems, the lower spatial resolution of the digital selenium and digital luminescence radiography systems does not affect detectability of fissures and bone lesions in porcine bone. Selenium is effective in skeletal radiography for detecting fissures and bone lesions. With digital selenium and digital luminescence radiography, the surface dose can be cut to half that required for 200-speed film-screen systems without losing any diagnostically relevant information.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
P. L. Kleinman, D. Zurakowski, K. J. Strauss, R. H. Cleveland, J. M. Perez-Rosello, D. P. Nichols, K. H. Zou, and P. K. Kleinman
Detection of Simulated Inflicted Metaphyseal Fractures in a Fetal Pig Model: Image Optimization and Dose Reduction with Computed Radiography
Radiology, May 1, 2008; 247(2): 381 - 390.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2001 by the American Roentgen Ray Society.