AJR Get Involved! Join ARRS Today
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lo, J. Y.
Right arrow Articles by Floyd, C. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lo, J. Y.
Right arrow Articles by Floyd, C. E., Jr.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2002; 178:457-463
© American Roentgen Ray Society


Cross-Institutional Evaluation of BI-RADS Predictive Model for Mammographic Diagnosis of Breast Cancer

Joseph Y. Lo1,2, Mia K. Markey1,2, Jay A. Baker1 and Carey E. Floyd, Jr.1,2

1 Department of Radiology, Duke University Medical Center, DUMC-3302, Bryan Research Bldg., Rm. 161G, Durham, NC 27710.
2 Department of Biomedical Engineering, Duke University, Durham, NC 27710.

OBJECTIVE. Given a predictive model for identifying very likely benign breast lesions on the basis of Breast Imaging Reporting and Data System (BI-RADS) mammographic findings, this study evaluated the model's ability to generalize to a patient data set from a different institution.

MATERIALS AND METHODS. The artificial neural network model underwent three trials: it was optimized over 500 biopsy-proven lesions from Duke University Medical Center or "Duke," evaluated on 1,000 similar cases from the University of Pennsylvania Health System or "Penn," and reoptimized for Penn.

RESULTS. Trial A's Duke-only model yielded 98% sensitivity, 36% specificity, area index (Az) of 0.86, and partial Az of 0.51. The cross-institutional trial B yielded 96% sensitivity, 28% specificity, Az of 0.79, and partial Az of 0.28. The decreases were significant for both Az (p = 0.017) and partial Az (p < 0.001). In trial C, the model reoptimized for the Penn data yielded 96% sensitivity, 35% specificity, Az of 0.83, and partial Az of 0.32. There were no significant differences compared with trial B for specificity (p = 0.44) or partial Az (p = 0.46), suggesting that the Penn data were inherently more difficult to characterize.

CONCLUSION. The BI-RADS lexicon facilitated the cross-institutional test of a breast cancer prediction model. The model generalized reasonably well, but there were significant performance decreases. The cross-institutional performance was encouraging because it was not significantly different from that of a reoptimized model using the second data set at high sensitivities. This study indicates the need for further work to collect more data and to improve the robustness of the model.