AJR Custom publishing of AJR articles and ARRS Cat. Course
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Barboriak, D. P.
Right arrow Articles by Provenzale, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Barboriak, D. P.
Right arrow Articles by Provenzale, J. M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2002; 179:245-250
© American Roentgen Ray Society


Evaluation of Software for Registration of Contrast-Enhanced Brain MR Images in Patients with Glioblastoma Multiforme

Daniel P. Barboriak1 and James M. Provenzale

1 Both authors: Department of Radiology, Box 3808, Duke University Medical Center, Durham, NC 27710.

OBJECTIVE. We evaluated commercially available software that rapidly and automatically registers brain MR images on a clinical workstation, and we studied the accuracy of these registrations.

SUBJECTS AND METHODS. Ten patients with a diagnosis of glioblastoma multiforme underwent contrast-enhanced inversion recovery prepared three-dimensional (3D) volumetric spoiled gradient-recalled acquisition in the steady state (SPGR) MR imaging (contiguous 1.5-mm slice thickness, 96-104 slices). After this imaging sequence, each patient was brought out of the head coil into a sitting position and then repositioned in the coil. The inversion recovery prepared 3D SPGR sequence was then repeated. A commercially available software program operating on a clinical workstation was used to automatically register the second inversion recovery prepared SPGR series to the first. The speed of registration was recorded. The accuracy of each registration was estimated by recording the coordinates of eight anatomic landmarks on the registered and reference series and by calculating the mean error among matching landmarks.

RESULTS. In nine of 10 patients, the registration software produced a visually satisfactory registration. In one patient, a second registration was necessary to produce a satisfactory registration. The processing time for each iteration was 48.3 ± 3.8 sec (mean ± SD). The mean error in aligning matching anatomic landmarks ranged from 0.67 to 1.41 mm, with an overall mean of 1.18 mm. The largest error among matching landmarks was 2.3 mm.

CONCLUSION. Commercially available registration software can automatically register 3D imaging volumes in less than 1 min. The mean error in registration was approximately equivalent to the dimensions of a single voxel.