AJR F and L Medical Products: Radiation Protection & More
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Honda, O.
Right arrow Articles by Müller, N. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Honda, O.
Right arrow Articles by Müller, N. L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2002; 179:875-879
© American Roentgen Ray Society


Comparison of Quality of Multiplanar Reconstructions and Direct Coronal Multidetector CT Scans of the Lung

Osamu Honda1, Takeshi Johkoh1, Shuji Yamamoto2, Mitsuhiro Koyama1, Noriyuki Tomiyama1, Takenori Kozuka1, Seiki Hamada1, Naoki Mihara1, Hironobu Nakamura1 and Nestor L. Müller3

1 Department of Radiology, Osaka University Graduate School of Medicine, 2-2 Yamadaoka, Suita, Osaka, 565-0871, Japan.
2 Department of Radiology, Osaka University Hospital, Osaka, 565-0871, Japan.
3 Department of Radiology, Vancouver Hospital and Health Sciences Centre and University of British Columbia, 855 W. 12th Ave., Vancouver, B. C. V5Z 1M9, Canada.

OBJECTIVE. The purpose of this study was to compare the quality of coronal multiplanar reconstructions with the quality of direct coronal thin-section multidetector CT (MDCT) scans.

MATERIALS AND METHODS. Axial multidetector CT (MDCT) scans were obtained through the entire lung in 10 normal autopsy lung specimens using an MDCT scanner. Four protocols were used: 0.5-mm collimation with a 0.5-mm reconstruction interval; 0.5-mm collimation with a 0.3-mm reconstruction interval; 1-mm collimation with a 0.5-mm reconstruction interval; and 2-mm collimation with a 1-mm reconstruction interval. Multiplanar reconstruction images with 0.5-mm slice thickness were obtained from the four types of data sets. Direct coronal thin-section CT of the same 10 autopsy lung specimens was performed using 0.5-mm scan collimation, a 0.3-mm reconstruction interval, a 25.6-cm field of view, and a 512 x 512 matrix. Two independent observers compared the image quality of each of the four coronal multiplanar reconstruction sets with that of direct coronal thin-section CT scans. The observers analyzed visualization of anatomic features and artifacts.

RESULTS. The total image quality of the multiplanar reconstructions obtained from 0.5-mm collimation data with or without 0.3-mm overlapping reconstruction was equal to that of direct coronal thin-section CT scans in all 20 interpretations. The image quality of multiplanar reconstruction images from 0.5-mm collimation data either with or without overlapping reconstruction was superior to multiplanar reconstruction images obtained from 1- or 2-mm collimation scans (p < 0.01, Fisher's exact test). Stairstep artifacts in multiplanar reconstructions using 0.5-mm collimation without overlapping reconstruction were equal to those with overlapping reconstruction and were fewer than those on 1- or 2-mm collimation (p < 0.01, Mann-Whitney U test).

CONCLUSION. The image quality of coronal multiplanar reconstructions from isotropic voxel data obtained using 0.5-mm collimation, with or without overlapping reconstruction, is similar to that of direct coronal thin-section CT scans.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
E. Y. Lee and P. M. Boiselle
Tracheobronchomalacia in Infants and Children: Multidetector CT Evaluation
Radiology, July 1, 2009; 252(1): 7 - 22.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Y. Lee, P. M. Boiselle, and R. H. Cleveland
Multidetector CT Evaluation of Congenital Lung Anomalies
Radiology, June 1, 2008; 247(3): 632 - 648.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E J CHOI, Y-W OH, S Y HAM, K Y LEE, and E-Y KANG
Comparison between coronal reformatted images and direct coronal CT images of the swine lung specimen: assessment of image quality with 64-detector row CT
Br. J. Radiol., June 1, 2008; 81(966): 463 - 467.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
V. La Fata, N. McLean, S.K. Wise, J.M. DelGaudio, and P.A. Hudgins
CSF Leaks: Correlation of High-Resolution CT and Multiplanar Reformations with Intraoperative Endoscopic Findings
AJNR Am. J. Neuroradiol., March 1, 2008; 29(3): 536 - 541.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. A. Jaffe, L. C. Martin, C. M. Miller, K. M. Franklin, E. M. Merkle, W. M. Thompson, R. C. Nelson, D. M. DeLong, and E. K. Paulson
Abdominal Pain: Coronal Reformations from Isotropic Voxels with 16-Section CT--Reader Lesion Detection and Interpretation Time
Radiology, January 1, 2007; 242(1): 175 - 181.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. D. Dodd, C. A. Souza, and N. L. Muller
High-resolution MDCT of pulmonary septic embolism: evaluation of the feeding vessel sign.
Am. J. Roentgenol., September 1, 2006; 187(3): 623 - 629.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. Takahashi, B. Thompson, W. Stanford, Y. Sato, K. Nagasawa, H. Sato, M. Kubota, A. Kashiba, and H. Sugimori
Visualization of normal pulmonary fissures on sagittal multiplanar reconstruction MDCT.
Am. J. Roentgenol., August 1, 2006; 187(2): 389 - 397.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. D. Dodd, C. A. Souza, and N. L. Muller
Conventional high-resolution CT versus helical high-resolution MDCT in the detection of bronchiectasis.
Am. J. Roentgenol., August 1, 2006; 187(2): 414 - 420.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. A. Jaffe, R. C. Nelson, G. A. Johnson, E. R. Lee, T. T. Yoshizumi, C. R. Lowry, A. B. Bullard, D. M. DeLong, and E. K. Paulson
Optimization of Multiplanar Reformations from Isotropic Data Sets Acquired with 16-Detector Row Helical CT Scanner
Radiology, January 1, 2006; 238(1): 292 - 299.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. A. Jaffe, L. C. Martin, J. Thomas, A. R. Adamson, D. M. DeLong, and E. K. Paulson
Small-Bowel Obstruction: Coronal Reformations from Isotropic Voxels at 16-Section Multi-Detector Row CT
Radiology, December 1, 2005; 238(1): 135 - 142.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. Matsuoka, Y. Kurihara, Y. Nakajima, H. Niimi, H. Ashida, and K. Kaneoya
Serial Change in Airway Lumen and Wall Thickness at Thin-Section CT in Asymptomatic Subjects
Radiology, February 1, 2005; 234(2): 595 - 603.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
W K Chooi and S K Morcos
High resolution volume imaging of airways and lung parenchyma with multislice CT
Br. J. Radiol., December 1, 2004; 77(suppl_1): S98 - S105.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Roentgen Ray Society.