AJR ARRS: Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Abdulla, C.
Right arrow Articles by Silverman, S. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Abdulla, C.
Right arrow Articles by Silverman, S. G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2002; 179:1473-1476
© American Roentgen Ray Society


Pseudoenhancement of Simulated Renal Cysts in a Phantom Using Different Multidetector CT Scanners

Cedela Abdulla1, Mannudeep K. Kalra1, Sanjay Saini1, Michael M. Maher1, Aamir Ahmad1, Elkan Halpern1 and Stuart G. Silverman2

1 Department of Radiology, Partners HealthCare System, Massachusetts General Hospital and Harvard Medical School, 55 Fruit St., Boston, MA 02114.
2 Department of Radiology, Partners HealthCare System, Brigham and Women's Hospital and Harvard Medical School, 75 Francis St., Boston, MA 02115.

OBJECTIVE. We undertook this study to determine whether pseudoenhancement of renal cysts occurs on scans obtained with multidetector CT (MDCT) scanners and whether the effect is influenced by scanning parameters.

MATERIALS AND METHODS. A kidney phantom with varying attenuation was created to simulate different levels of renal parenchymal enhancement (150 and 250 H). Two water-filled cylinders simulating renal cysts—one with a 5-mm diameter and one with a 15-mm diameter—were suspended in the "kidney." After validating the pseudoenhancement effect produced in our phantom model with a single-detector helical CT scanner, we investigated the effect with matrix array and adaptive array MDCT scanners using detector configurations of 1.25 and 2.5 mm and beam pitches of 0.75:1.0 and 1.5:1.0 at an effective reconstructed slice thickness of approximately 3 mm. Three sets of experiments were performed at each setting, and mean cyst density was measured. Data were statistically analyzed using the Student's t test and multiple logistic regression analysis when appropriate.

RESULTS. Although pseudoenhancement was observed with MDCT scanners, the effect was statistically significant only for scans depicting the smaller cyst at a background renal density of 250 H on the matrix array MDCT. Modulation of scanning parameters did not alter these findings. Pseudoenhancement was significantly higher with the matrix array MDCT scanner than with the adaptive array MDCT scanner (p < 0.05).

CONCLUSION. In our phantom model, high levels of renal enhancement produced pseudoenhancement in small renal cysts with different models of MDCT scanners, irrespective of pitch or detector configuration.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
Z. J. Wang, F. V. Coakley, Y. Fu, B. N. Joe, S. Prevrhal, L. A. Landeras, E. M. Webb, and B. M. Yeh
Renal Cyst Pseudoenhancement at Multidetector CT: What Are the Effects of Number of Detectors and Peak Tube Voltage?
Radiology, September 1, 2008; 248(3): 910 - 916.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
G. M. Israel and M. A. Bosniak
Pitfalls in Renal Mass Evaluation and How to Avoid Them
RadioGraphics, September 1, 2008; 28(5): 1325 - 1338.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
B. A. Birnbaum, N. Hindman, J. Lee, and J. S. Babb
Renal Cyst Pseudoenhancement: Influence of Multidetector CT Reconstruction Algorithm and Scanner Type in Phantom Model
Radiology, September 1, 2007; 244(3): 767 - 775.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. M. Israel and M. A. Bosniak
How I Do It: Evaluating Renal Masses
Radiology, August 1, 2005; 236(2): 441 - 450.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Roentgen Ray Society.