AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pfarl, G.
Right arrow Articles by Liberman, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pfarl, G.
Right arrow Articles by Liberman, L.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2002; 179:1503-1507
© American Roentgen Ray Society


Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study

Georg Pfarl1, Thomas H. Helbich1, Christopher C. Riedl1, Teresa Wagner2, Michael Gnant3, Margaretha Rudas4 and Laura Liberman5

1 Department of Radiology, University of Vienna Medical School, AKH Wien, Waehringer Guertel 18-20, A-1090 Vienna, Austria.
2 Department of Gynecology, University of Vienna Medical School, AKH Wien, A-1090 Vienna, Austria.
3 Department of Surgery, University of Vienna Medical School, AKH Wien, A-1090 Vienna, Austria.
4 Department of Pathology, University of Vienna Medical School, AKH Wien, A-1090 Vienna, Austria.
5 Breast Imaging Section, Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Ave., New York, NY 10021.

OBJECTIVE. The aim of our study was to determine the false-negative rate of stereotactic 11-gauge vacuum-assisted biopsy in a validation study of lesions that had subsequent surgical excision.

MATERIALS AND METHODS. Retrospective review was performed of 318 lesions that underwent stereotactic 11-gauge vacuum-assisted biopsy and subsequent surgical excision. A false-negative case was defined as a pathologically proven cancer in which stereotactic biopsy yielded benign results without atypia. Medical records, imaging studies, and histologic findings were reviewed.

RESULTS. False-negative findings were encountered at stereotactic 11-gauge vacuum-assisted biopsy in 3.3% (7/214) of pathologically proven cancers. False-negative findings occurred in 3.5% (4/115) of malignant calcification lesions versus 3.0% (3/99) of malignant masses (p = 1.0). The seven false-negative findings included five Breast Imaging Reporting and Data System (BI-RADS) category 5 lesions that yielded benign results at biopsy, one BI-RADS category 4 mass that benign breast tissue, and one BI-RADS category 4 cluster of calcifications in which no calcifications were retrieved. The false-negative rate was 10.0% (6/60) for radiologists who performed 15 or fewer previous stereotactic vacuum-assisted biopsy procedures versus 0.6% (1/154) for radiologists who performed more than 15 previous stereotactic vacuum-assisted biopsy procedures (p = 0.002).

CONCLUSION. Stereotactic 11-gauge vacuum-assisted biopsy had a false-negative rate of 3.3% that diminished to 0.6% with experience. All false-negative findings could be prospectively identified because of failure to sample calcifications or imaging-histologic discordance.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. Jang, N. Cho, W. K. Moon, J. S. Park, M. H. Seong, and I. A. Park
Underestimation of Atypical Ductal Hyperplasia at Sonographically Guided Core Biopsy of the Breast
Am. J. Roentgenol., November 1, 2008; 191(5): 1347 - 1351.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich
US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases
Radiology, August 1, 2008; 248(2): 406 - 413.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Pathol.Home page
V Kumaroswamy, J Liston, and A M Shaaban
Vacuum assisted stereotactic guided mammotome biopsies in the management of screen detected microcalcifications: experience of a large breast screening centre
J. Clin. Pathol., June 1, 2008; 61(6): 766 - 769.
[Abstract] [Full Text] [PDF]


Home page
Clin. Cancer Res.Home page
C. C. Riedl, L. Ponhold, D. Flory, M. Weber, R. Kroiss, T. Wagner, M. Fuchsjager, and T. H. Helbich
Magnetic Resonance Imaging of the Breast Improves Detection of Invasive Cancer, Preinvasive Cancer, and Premalignant Lesions during Surveillance of Women at High Risk for Breast Cancer
Clin. Cancer Res., October 15, 2007; 13(20): 6144 - 6152.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. J. Jackman and J. Rodriguez-Soto
Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.
Radiology, April 1, 2006; 239(1): 61 - 70.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. C. Riedl, G. Pfarl, M. Memarsadeghi, T. Wagner, F. Fitzal, M. Rudas, and T. H. Helbich
Lesion Miss Rates and False-Negative Rates for 1115 Consecutive Cases of Stereotactically Guided Needle-localized Open Breast Biopsy with Long-term Follow-up
Radiology, December 1, 2005; 237(3): 847 - 853.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, N. Bracero, E. Morris, C. Thornton, and D. D. Dershaw
MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy: Initial Clinical Experience
Am. J. Roentgenol., July 1, 2005; 185(1): 183 - 193.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman
Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy
Radiology, September 1, 2004; 232(3): 897 - 903.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
X. Chen, C. D. Lehman, and K. E. Dee
MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy Needle
Am. J. Roentgenol., April 1, 2004; 182(4): 1075 - 1080.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. Liberman, E. A. Morris, D. D. Dershaw, C. M. Thornton, K. J. Van Zee, and L. K. Tan
Fast MRI-Guided Vacuum-Assisted Breast Biopsy: Initial Experience
Am. J. Roentgenol., November 1, 2003; 181(5): 1283 - 1293.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2002 by the American Roentgen Ray Society.