|
|
||||||||
1 Department of Radiology, University of Vienna Medical School, AKH Wien,
Waehringer Guertel 18-20, A-1090 Vienna, Austria.
2 Department of Gynecology, University of Vienna Medical School, AKH Wien,
A-1090 Vienna, Austria.
3 Department of Surgery, University of Vienna Medical School, AKH Wien, A-1090
Vienna, Austria.
4 Department of Pathology, University of Vienna Medical School, AKH Wien, A-1090
Vienna, Austria.
5 Breast Imaging Section, Department of Radiology, Memorial Sloan-Kettering
Cancer Center, 1275 York Ave., New York, NY 10021.
OBJECTIVE. The aim of our study was to determine the false-negative rate of stereotactic 11-gauge vacuum-assisted biopsy in a validation study of lesions that had subsequent surgical excision.
MATERIALS AND METHODS. Retrospective review was performed of 318 lesions that underwent stereotactic 11-gauge vacuum-assisted biopsy and subsequent surgical excision. A false-negative case was defined as a pathologically proven cancer in which stereotactic biopsy yielded benign results without atypia. Medical records, imaging studies, and histologic findings were reviewed.
RESULTS. False-negative findings were encountered at stereotactic 11-gauge vacuum-assisted biopsy in 3.3% (7/214) of pathologically proven cancers. False-negative findings occurred in 3.5% (4/115) of malignant calcification lesions versus 3.0% (3/99) of malignant masses (p = 1.0). The seven false-negative findings included five Breast Imaging Reporting and Data System (BI-RADS) category 5 lesions that yielded benign results at biopsy, one BI-RADS category 4 mass that benign breast tissue, and one BI-RADS category 4 cluster of calcifications in which no calcifications were retrieved. The false-negative rate was 10.0% (6/60) for radiologists who performed 15 or fewer previous stereotactic vacuum-assisted biopsy procedures versus 0.6% (1/154) for radiologists who performed more than 15 previous stereotactic vacuum-assisted biopsy procedures (p = 0.002).
CONCLUSION. Stereotactic 11-gauge vacuum-assisted biopsy had a false-negative rate of 3.3% that diminished to 0.6% with experience. All false-negative findings could be prospectively identified because of failure to sample calcifications or imaging-histologic discordance.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
M. Jang, N. Cho, W. K. Moon, J. S. Park, M. H. Seong, and I. A. Park Underestimation of Atypical Ductal Hyperplasia at Sonographically Guided Core Biopsy of the Breast Am. J. Roentgenol., November 1, 2008; 191(5): 1347 - 1351. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Schueller, S. Jaromi, L. Ponhold, M. Fuchsjaeger, M. Memarsadeghi, M. Rudas, M. Weber, L. Liberman, and T. H. Helbich US-guided 14-gauge Core-Needle Breast Biopsy: Results of a Validation Study in 1352 Cases Radiology, August 1, 2008; 248(2): 406 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Kumaroswamy, J Liston, and A M Shaaban Vacuum assisted stereotactic guided mammotome biopsies in the management of screen detected microcalcifications: experience of a large breast screening centre J. Clin. Pathol., June 1, 2008; 61(6): 766 - 769. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Riedl, L. Ponhold, D. Flory, M. Weber, R. Kroiss, T. Wagner, M. Fuchsjager, and T. H. Helbich Magnetic Resonance Imaging of the Breast Improves Detection of Invasive Cancer, Preinvasive Cancer, and Premalignant Lesions during Surveillance of Women at High Risk for Breast Cancer Clin. Cancer Res., October 15, 2007; 13(20): 6144 - 6152. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Jackman and J. Rodriguez-Soto Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome. Radiology, April 1, 2006; 239(1): 61 - 70. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. C. Riedl, G. Pfarl, M. Memarsadeghi, T. Wagner, F. Fitzal, M. Rudas, and T. H. Helbich Lesion Miss Rates and False-Negative Rates for 1115 Consecutive Cases of Stereotactically Guided Needle-localized Open Breast Biopsy with Long-term Follow-up Radiology, December 1, 2005; 237(3): 847 - 853. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, N. Bracero, E. Morris, C. Thornton, and D. D. Dershaw MRI-Guided 9-Gauge Vacuum-Assisted Breast Biopsy: Initial Clinical Experience Am. J. Roentgenol., July 1, 2005; 185(1): 183 - 193. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Lomoschitz, T. H. Helbich, M. Rudas, G. Pfarl, K. F. Linnau, A. Stadler, and R. J. Jackman Stereotactic 11-gauge Vacuum-assisted Breast Biopsy: Influence of Number of Specimens on Diagnostic Accuracy Radiology, September 1, 2004; 232(3): 897 - 903. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. Chen, C. D. Lehman, and K. E. Dee MRI-Guided Breast Biopsy: Clinical Experience with 14-Gauge Stainless Steel Core Biopsy Needle Am. J. Roentgenol., April 1, 2004; 182(4): 1075 - 1080. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Liberman, E. A. Morris, D. D. Dershaw, C. M. Thornton, K. J. Van Zee, and L. K. Tan Fast MRI-Guided Vacuum-Assisted Breast Biopsy: Initial Experience Am. J. Roentgenol., November 1, 2003; 181(5): 1283 - 1293. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |