AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mallouhi, A.
Right arrow Articles by Jaschke, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mallouhi, A.
Right arrow Articles by Jaschke, W. R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2003; 180:233-239
© American Roentgen Ray Society


Volume-Rendered Multidetector CT Angiography: Noninvasive Follow-Up of Patients Treated with Renal Artery Stents

Ammar Mallouhi1, Michael Rieger, Benedikt Czermak, Martin C. Freund, Peter Waldenberger and Werner R. Jaschke

1 All authors: Department of Radiology, Innsbruck University Hospital, Anichstra. 35, 6020 Innsbruck, Austria.

OBJECTIVE. The purpose of our study was to evaluate the role of multidetector CT (MDCT) angiography with volume rendering for estimating the patency of renal artery stents.

SUBJECTS AND METHODS. In 16 patients, 16 renal artery stents were evaluated with MDCT renal angiography and digital subtraction angiography (DSA). CT data were evaluated using multiplanar volume reformations and the volume-rendering algorithm with three different volume-rendered parameter settings (low-to-high, high-to-low, and high—low—high opacity transfer functions: VRLH, VRHL, and VRVE, respectively). Targeted images of each stent were rendered in paraaxial and paracoronal planes and were interactively interpreted. The overall restenosis severity was measured on postprocessed paraaxial and paracoronal images and compared with that obtained on DSA using linear regression analysis. Image quality and lumen delineation on rendered images were also compared using Wilcoxon's signed rank test.

RESULTS. Eight restenoses were identified on DSA. Correlations between restenosis severity measured with DSA and those measured with MDCT were significant (p < 0.001). Volume rendering with VRHL allowed the best correlation with DSA (reviewer 1, r2 = 0.86; reviewer 2, r2 = 0.94) and was significantly better than multiplanar volume reformations (p = 0.028). Overall image quality was high with all rendering techniques and with no significant differences (p > 0.59, for all comparisons). Stent lumen was well delineated with volume-rendering modalities; however, VRHL was significantly better than VRLH (p = 0.033).

CONCLUSION. Volume-rendered MDCT angiography enabled high-quality three-dimensional reproducible evaluation of the patency of implanted renal artery stents. Volume rendering with VRHL achieved the best performance.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
M. Rieger, A. Mallouhi, T. Tauscher, M. Lutz, and W. R. Jaschke
Traumatic Arterial Injuries of the Extremities: Initial Evaluation with MDCT Angiography.
Am. J. Roentgenol., March 1, 2006; 186(3): 656 - 664.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. T. Johnson and E. K. Fishman
IV Contrast Selection for MDCT: Current Thoughts and Practice
Am. J. Roentgenol., February 1, 2006; 186(2): 406 - 415.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Suzuki, S. Furui, and T. Kaminaga
Accuracy of Automated CT Angiography Measurement of Vascular Diameter in Phantoms: Effect of Size of Display Field of View, Density of Contrast Medium, and Wall Thickness
Am. J. Roentgenol., June 1, 2005; 184(6): 1940 - 1944.
[Abstract] [Full Text] [PDF]


Home page
J Ultrasound MedHome page
Z. Morvay, E. Nagy, R. Bagi, G. Abraham, R. Sipka, and A. Palko
Sonographic Follow-up After Visceral Artery Stenting
J. Ultrasound Med., August 1, 2004; 23(8): 1057 - 1064.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. Suzuki, S. Furui, T. Kaminaga, and T. Yamauchi
Measurement of Vascular Diameter In Vitro by Automated Software for CT Angiography: Effects of Inner Diameter, Density of Contrast Medium, and Convolution Kernel
Am. J. Roentgenol., May 1, 2004; 182(5): 1313 - 1317.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. Sheth and E. K. Fishman
Multi-Detector Row CT of the Kidneys and Urinary Tract: Techniques and Applications in the Diagnosis of Benign Diseases
RadioGraphics, March 1, 2004; 24(2): e20 - e20.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Roentgen Ray Society.