AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Fricke, B. L.
Right arrow Articles by Lucaya, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fricke, B. L.
Right arrow Articles by Lucaya, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2003; 180:407-411
© American Roentgen Ray Society


In-Plane Bismuth Breast Shields for Pediatric CT: Effects on Radiation Dose and Image Quality Using Experimental and Clinical Data

Bradley L. Fricke1, Lane F. Donnelly1, Donald P. Frush2, Terry Yoshizumi2, Vladimir Varchena3, Stacy A. Poe1 and Javier Lucaya4

1 Departments of Radiology and Pediatrics, Cincinnati Children's Hospital Medical Center and University of Cincinnati College of Medicine, 3333 Burnet Ave., Cincinnati, OH 45229-3039.
2 Department of Radiology, Box 3808, Duke University Medical Center, Durham, NC 27710.
3 Computed Imaging Reference Systems, Inc., Norfolk, VA 23513.
4 Radiologia Pediatrica, Hospital Materno-Infantil Vall d'He, pg. Vall d'Hebron 119-129, E-08-35, Barcelona, Spain.

OBJECTIVE. The purpose of our study was to evaluate the amount of radiation dose reduction and its effect on image quality when using an in-plane bismuth breast shield for multidetector CT (MDCT) of the chest and abdomen in female pediatric patients.

SUBJECTS AND METHODS. Fifty consecutive MDCT examinations (chest, 29; abdomen, 21) of female pediatric patients (mean age, 9 years; range, 2 months-18 years) were performed with a 2-ply (1.7 g of bismuth per square centimeter) bismuth shield (three sizes to accommodate patients of varying sizes) overlying the patient's breasts. MDCT images were evaluated for a perceptible difference in image quality in the lungs at the anatomic level under the shield as compared with nonshielded lung and whether the images were of diagnostic quality. In addition, 2-mm regions of interest were placed in the peripheral anterior and posterior portions of each lung in shielded and nonshielded areas, and noise (standard deviation in Hounsfield units) was measured in the regions. Differences among the regions in noise were compared for shielded versus nonshielded areas (paired t test). To measure differences in actual dose, we also evaluated the breast shield with an infant anthropomorphic phantom using thermoluminescent detectors in the breast tissue. The phantom was imaged with and without the breast shield using identical MDCT parameters.

RESULTS. All MDCT scans of patients were of diagnostic quality with no perceptible difference in image quality in shielded versus nonshielded lung. We found no statistically significant difference in noise between the shielded and nonshielded lung regions of interest (shielded: mean noise, 17.3 H; nonshielded: mean noise, 18.8 H; p = 0.5180). Phantom measurements revealed a 29% reduction in radiation dose to the breast when a medium-dose MDCT protocol was used.

CONCLUSION. Bismuth in-plane breast shielding for pediatric MDCT decreased radiation dose to the breast without qualitative or quantitative changes in image quality.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Matsuoka, A. R. Hunsaker, R. R. Gill, I. B. Oliva, B. Trotman-Dickenson, F. L. Jacobson, and H. Hatabu
Vascular Enhancement and Image Quality of MDCT Pulmonary Angiography in 400 Cases: Comparison of Standard and Low Kilovoltage Settings
Am. J. Roentgenol., June 1, 2009; 192(6): 1651 - 1656.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Kim, T. T. Yoshizumi, D. P. Frush, C. Anderson-Evans, and G. Toncheva
DOSIMETRIC CHARACTERISATION OF BISMUTH SHIELDS IN CT: MEASUREMENTS AND MONTE CARLO SIMULATIONS
Radiat Prot Dosimetry, March 5, 2009; (2009) ncp025v1.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. R. Mayo and J. A. Leipsic
Radiation Dose in Cardiac CT
Am. J. Roentgenol., March 1, 2009; 192(3): 646 - 653.
[Abstract] [Full Text] [PDF]


Home page
Proc Am Thorac SocHome page
J. R. Mayo
Radiation Dose Issues in Longitudinal Studies Involving Computed Tomography
Proceedings of the ATS, December 15, 2008; 5(9): 934 - 939.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. E. Ngaile, C. B. S. Uiso, P. Msaki, and R. Kazema
Use of lead shields for radiation protection of superficial organs in patients undergoing head CT examinations
Radiat Prot Dosimetry, July 1, 2008; 130(4): 490 - 498.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Honnef, J. E. Wildberger, G. Haras, C. Hohl, G. Staatz, R. W. Gunther, and A. H. Mahnken
Prospective Evaluation of Image Quality with Use of a Patient Image Gallery for Dose Reduction in Pediatric 16-MDCT
Am. J. Roentgenol., February 1, 2008; 190(2): 467 - 473.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Coursey, D. P. Frush, T. Yoshizumi, G. Toncheva, G. Nguyen, and S. B. Greenberg
Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast Shielding
Am. J. Roentgenol., January 1, 2008; 190(1): W54 - W61.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
E V Kennedy, G R Iball, and D S Brettle
Investigation into the effects of lead shielding for fetal dose reduction in CT pulmonary angiography
Br. J. Radiol., August 1, 2007; 80(956): 631 - 638.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
H. Warren-Forward, P. Cardew, B. Smith, L. Clack, K. McWhirter, S. Johnson, and K. Wessel
A COMPARISON OF DOSE SAVINGS OF LEAD AND LIGHTWEIGHT APRONS FOR SHIELDING OF 99m-TECHNETIUM RADIATION
Radiat Prot Dosimetry, May 24, 2007; (2007) ncm176v1.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. T. Yoshizumi, P. C. Goodman, D. P. Frush, G. Nguyen, G. Toncheva, M. Sarder, and L. Barnes
Validation of Metal Oxide Semiconductor Field Effect Transistor Technology for Organ Dose Assessment During CT: Comparison with Thermoluminescent Dosimetry
Am. J. Roentgenol., May 1, 2007; 188(5): 1332 - 1336.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
C. Schueller-Weidekamm, C. M. Schaefer-Prokop, M. Weber, C. J. Herold, and M. Prokop
CT Angiography of Pulmonary Arteries to Detect Pulmonary Embolism: Improvement of Vascular Enhancement with Low Kilovoltage Settings
Radiology, December 1, 2006; 241(3): 899 - 907.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. M. Hurwitz, T. T. Yoshizumi, R. E. Reiman, E. K. Paulson, D. P. Frush, G. T. Nguyen, G. I. Toncheva, and P. C. Goodman
Radiation dose to the female breast from 16-MDCT body protocols.
Am. J. Roentgenol., June 1, 2006; 186(6): 1718 - 1722.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. S. Parker, F. K. Hui, M. A. Camacho, J. K. Chung, D. W. Broga, and N. N. Sethi
Female Breast Radiation Exposure During CT Pulmonary Angiography
Am. J. Roentgenol., November 1, 2005; 185(5): 1228 - 1233.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
M A Lewis and S Edyvean
Patient dose reduction in CT
Br. J. Radiol., October 1, 2005; 78(934): 880 - 883.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. F. Donnelly
Reducing Radiation Dose Associated with Pediatric CT by Decreasing Unnecessary Examinations
Am. J. Roentgenol., February 1, 2005; 184(2): 655 - 657.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Hohl, A. H. Mahnken, E. Klotz, M. Das, A. Stargardt, G. Muhlenbruch, T. Schmidt, R. W. Gunther, and J. E. Wildberger
Radiation Dose Reduction to the Male Gonads During MDCT: The Effectiveness of a Lead Shield
Am. J. Roentgenol., January 1, 2005; 184(1): 128 - 130.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
D. P. Frush, L. F. Donnelly, and N. S. Rosen
Computed Tomography and Radiation Risks: What Pediatric Health Care Providers Should Know
Pediatrics, October 1, 2003; 112(4): 951 - 957.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
L. F. Donnelly, J. Lucaya, V. Ozelame, D. P. Frush, P. J. Strouse, T. E. Sumner, and H. J. Paltiel
CT Findings and Temporal Course of Persistent Pulmonary Interstitial Emphysema in Neonates: A Multiinstitutional Study
Am. J. Roentgenol., April 1, 2003; 180(4): 1129 - 1133.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Roentgen Ray Society.