1 All authors: Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii, Kawaramachi-Hirokoji, Kamigyo, Kyoto, 602-8566, Japan.
OBJECTIVE. The goal of our study was to evaluate the efficacy of the combined use of fine-needle aspiration and tissue core biopsy under real-time CT fluoroscopy guidance.
SUBJECTS AND METHODS. One hundred thirty-eight percutaneous needle lung biopsy samples were obtained by two methods. The samples obtained by tissue fine-needle aspiration underwent cytologic evaluation, and those obtained by core biopsy using an automated cutting needle underwent histologic evaluation. The final diagnosis was confirmed by independent surgical pathologic findings, independent culture results, or clinical follow-up.
RESULTS. Rates of adequate specimens obtained and of precise diagnosis by combined use of fine-needle aspiration and core biopsy were 97.1% (134/138) and 94.2% (130/138) evaluated lung lesions, respectively, whereas those rates were 84.8% (117/138) and 79.7% (110/138) by fine-needle aspiration alone and 91.3% (126/138) and 89.1% (123/138) by core biopsy alone, respectively. Precise diagnosis was achieved by the combined use of the techniques in 30 (93.8%) of 32 lesions ranging from 3 to 10 mm in diameter, 42 (93.3%) of 45 lesions ranging from 11 to 20 mm, 43 (93.5%) of 46 lesions ranging from 21 to 30 mm, and 100% of 15 lesions ranging from 31 to 100 mm. In 89 of 90 lesions shown to be malignant by CT-guided lung biopsy and 30 of 44 shown to be benign, specific cell types could be proven from specimens obtained by the combined use of the two different types of needle biopsy.
CONCLUSION. The combined use of fine-needle aspiration and core biopsy improves the diagnostic ability of CT fluoroscopyguided lung biopsy, even in small lesions.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
R YOSHIMATSU, T YAMAGAMI, T KATO, T HIROTA, T MATSUMOTO, J SHIMADA, and T NISHIMURA Percutaneous needle biopsy of lung nodules under CT fluoroscopic guidance with use of the "I-I device" Br. J. Radiol., February 1, 2008; 81(962): 107 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y-C. Chang, C-J. Yu, W-J. Lee, S-H. Kuo, C-H. Hsiao, I-S. Jan, F-C. Hu, H-M. Liu, W-K. Chan, and P-C. Yang Imprint cytology improves accuracy of computed tomography-guided percutaneous transthoracic needle biopsy Eur. Respir. J., January 1, 2008; 31(1): 54 - 61. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. MacMahon, J. H. M. Austin, G. Gamsu, C. J. Herold, J. R. Jett, D. P. Naidich, E. F. Patz Jr, and S. J. Swensen Guidelines for Management of Small Pulmonary Nodules Detected on CT Scans: A Statement from the Fleischner Society Radiology, November 1, 2005; 237(2): 395 - 400. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yamagami, T. Kato, S. Iida, T. Hirota, and T. Nishimura Percutaneous Needle Biopsy for Small Lung Nodules Beneath the Rib Under CT Scan Fluoroscopic Guidance With Gantry Tilt Chest, September 1, 2004; 126(3): 744 - 747. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |