AJR Your Link to CME
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Donnelly, L. F.
Right arrow Articles by Daniels, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Donnelly, L. F.
Right arrow Articles by Daniels, S. R.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2003; 180:993-998
© American Roentgen Ray Society


Using a Phantom to Compare MR Techniques for Determining the Ratio of Intraabdominal to Subcutaneous Adipose Tissue

Lane F. Donnelly1,2, Kendall J. O'Brien1, Bernard J. Dardzinski1,2, Stacy A. Poe2, Judy A. Bean2, Scott K. Holland1,2 and Stephen R. Daniels2

1 Department of Radiology, Cincinnati Children's Hospital Medical Center and University of Cincinnati, 3333 Burnet Ave., Cincinnati, OH 45229-3039.
2 Department of Pediatrics, Cincinnati Children's Hospital Medical Center and University of Cincinnati, Cincinnati, OH 45229-3039.

OBJECTIVE. Patients who have a greater distribution of intraabdominal adipose tissue as compared with subcutaneous adipose tissue and an increased ratio of intraabdominal adipose tissue to subcutaneous adipose tissue are at greater risk for developing cardiovascular disease and type 2 diabetes mellitus. In previous MR investigations, researchers have used conventional T1-weighted spin-echo images to determine the ratio of intraabdominal adipose tissue to subcutaneous adipose tissue. However, no investigation, to our knowledge, has been performed to determine the accuracy of using different MR sequences to estimate adipose distribution. The purpose of our investigation was to compare MR imaging and segmentation techniques in calculating the ratio of intraabdominal to subcutaneous adipose tissue using an adiposity phantom.

MATERIALS AND METHODS. A phantom was created to simulate the distribution of subcutaneous and intraabdominal fat (with known volumes). Axial MR images were obtained twice through the phantom using a 5-mm slice thickness and zero gap for the following T1-weighted sequences: spin-echo, fast Dixon, and three-dimensional (3D) spoiled gradient-echo. An in-house computer software program was then used to segment the volumes of fat and calculate the volume of intraabdominal adipose tissue and subcutaneous adipose tissue and the ratio of intraabdominal to subcutaneous adipose tissue. Each imaging data set was segmented three times, so six sets of data were yielded for each imaging technique. The percentage predicted of the true volume was calculated for each MR imaging technique for each fat variable. The mean percentages for each variable were then compared using one-factor analysis of variance to determine whether differences exist among the three MR techniques.

RESULTS. The three MR imaging techniques had statistically significant different means for the predicted true volume of two variables: volume of subcutaneous adipose tissue (p < 0.001) and volume of intraabdominal adipose tissue (p = 0.0426). Estimates based on fast Dixon images were closest to the true volumes for all the variables. All MR imaging techniques performed similarly in estimating the ratio of intraabdominal adipose tissue to subcutaneous adipose tissue (p = 0.9117). The acquisition time for the 3D spoiled gradient-echo images was 10–22 times faster than for the other sequences.

CONCLUSION. Conventional T1-weighted spin-echo MR imaging, the current sequence used in practice for measuring visceral adiposity, may not be the optimal MR sequence for this purpose. We found that the T1-weighted fast Dixon sequence was the most accurate at estimating all fat volumes. The T1-weighted 3D spoiled gradient-echo sequence generated similar ratios of intraabdominal to subcutaneous adipose tissue in a fraction of the acquisition time.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Clin. Nutr.Home page
B. E Saelens, R. J Seeley, K. van Schaick, L. F Donnelly, and K. J O'Brien
Visceral abdominal fat is correlated with whole-body fat and physical activity among 8-y-old children at risk of obesity
Am. J. Clinical Nutrition, January 1, 2007; 85(1): 46 - 53.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Du, B. J. Dardzinski, K. J. O'Brien, and L. F. Donnelly
MRI of Fat Distribution in a Mouse Model of Lysosomal Acid Lipase Deficiency
Am. J. Roentgenol., February 1, 2005; 184(2): 658 - 662.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Roentgen Ray Society.