AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tack, D.
Right arrow Articles by Gevenois, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tack, D.
Right arrow Articles by Gevenois, P. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2003; 181:331-334
© American Roentgen Ray Society


Dose Reduction in Multidetector CT Using Attenuation-Based Online Tube Current Modulation

Denis Tack1, Viviane De Maertelaer2 and Pierre Alain Gevenois3

1 Department of Radiology, Centre Hospitalier Universitaire de Charleroi, Boulevard Janson, 92, B-6000-Charleroi, Belgium.
2 Statistical Unit, Institut de Recherche Interdisciplinaire en Biologie Humaine et Moléculaire, Université Libre de Bruxelles, Route de Lennik, 808, Brussels, B1070 Belgium.
3 Department of Radiology, Hôpital Erasme, Université Libre de Bruxelles, Brussels, B1070 Belgium.

OBJECTIVE. This study was designed to quantify the radiation dose saved by attenuation-based online tube current modulation applied to multidetector CT (MDCT) of the adult trunk as a function of effective milliampere-second (mAs) presets, sex, and body habitus.

SUBJECTS AND METHODS. One hundred twenty patients underwent MDCT of the trunk (60 thoracic, 60 abdominal) with an attenuation-based online tube current modulation. Consecutive acquisitions at standard and two lower effective mAs presets were obtained in each patient. Mean percentage effective mAs reductions were compared for each effective mAs preset, taking into account sex and body mass index.

RESULTS. Mean effective mAs reduction was 16.9% and 20.0% for the chest and the abdomen, respectively. Mean percentage effective mAs reductions were found to be significantly different for sex (chest, p = 0.003; abdomen, p = 0.002) but not significantly different for the different effective mAs presets or body mass index.

CONCLUSION. Attenuation-based online tube current modulation used with MDCT should be considered as a secondary tool of radiation dose reduction because it saves as much as 20% of the radiation dose on the adult trunk, regardless of initial mAs preset. However, initial decreases of mAs presets by the physician should be considered the primary tool for radiation dose reduction.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
D. Roggenland, S. A. Peters, S. P. Lemburg, T. Holland-Letz, V. Nicolas, and C. M. Heyer
CT Angiography in Suspected Pulmonary Embolism: Impact of Patient Characteristics and Different Venous Lines on Vessel Enhancement and Image Quality
Am. J. Roentgenol., June 1, 2008; 190(6): W351 - W359.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
K. Matsubara, K. Koshida, M. Suzuki, H. Tsujii, T. Yamamoto, and O. Matsui
Comparison between 3-D and z-axis automatic tube current modulation technique in multidetector-row CT
Radiat Prot Dosimetry, January 1, 2008; 128(1): 106 - 111.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. Coursey, D. P. Frush, T. Yoshizumi, G. Toncheva, G. Nguyen, and S. B. Greenberg
Pediatric Chest MDCT Using Tube Current Modulation: Effect on Radiation Dose with Breast Shielding
Am. J. Roentgenol., January 1, 2008; 190(1): W54 - W61.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. D. MacKenzie, J. Nazario-Larrieu, T. Cai, M. S. Ledbetter, M. A. Duran-Mendicuti, P. F. Judy, and F. J. Rybicki
Reduced-Dose CT: Effect on Reader Evaluation in Detection of Pulmonary Embolism
Am. J. Roentgenol., December 1, 2007; 189(6): 1371 - 1379.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. A. Jaffe, A. M. Gaca, S. Delaney, T. T. Yoshizumi, G. Toncheva, G. Nguyen, and D. P. Frush
Radiation Doses from Small-Bowel Follow-Through and Abdominopelvic MDCT in Crohn's Disease
Am. J. Roentgenol., November 1, 2007; 189(5): 1015 - 1022.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
K. M. Kanal, B. K. Stewart, O. Kolokythas, and W. P. Shuman
Impact of Operator-Selected Image Noise Index and Reconstruction Slice Thickness on Patient Radiation Dose in 64-MDCT
Am. J. Roentgenol., July 1, 2007; 189(1): 219 - 225.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
A J Van Der Molen, W J H Veldkamp, and J Geleijns
16-slice CT: achievable effective doses of common protocols in comparison with recent CT dose surveys
Br. J. Radiol., April 1, 2007; 80(952): 248 - 255.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. Graser, B. J. Wintersperger, C. Suess, M. F. Reiser, and C. R. Becker
Dose reduction and image quality in MDCT colonography using tube current modulation.
Am. J. Roentgenol., September 1, 2006; 187(3): 695 - 701.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
E. Coche, S. Vynckier, and M. Octave-Prignot
Pulmonary Embolism: Radiation Dose with Multi-Detector Row CT and Digital Angiography for Diagnosis
Radiology, September 1, 2006; 240(3): 690 - 697.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
G R Iball, D S Brettle, and A C Moore
Assessment of tube current modulation in pelvic CT
Br. J. Radiol., January 1, 2006; 79(937): 62 - 70.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. Campbell, M. K. Kalra, S. Rizzo, M. M. Maher, and J.-A. Shepard
Scanning Beyond Anatomic Limits of the Thorax in Chest CT: Findings, Radiation Dose, and Automatic Tube Current Modulation
Am. J. Roentgenol., December 1, 2005; 185(6): 1525 - 1530.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, S. Rizzo, M. M. Maher, E. F. Halpern, T. L. Toth, J.-A. O. Shepard, and S. L. Aquino
Chest CT Performed with Z-Axis Modulation: Scanning Protocol and Radiation Dose
Radiology, October 1, 2005; 237(1): 303 - 308.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. H. Mulkens, P. Bellinck, M. Baeyaert, D. Ghysen, X. Van Dijck, E. Mussen, C. Venstermans, and J.-L. Termote
Use of an Automatic Exposure Control Mechanism for Dose Optimization in Multi-Detector Row CT Examinations: Clinical Evaluation
Radiology, October 1, 2005; 237(1): 213 - 223.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
D. Tack, P. Bohy, I. Perlot, V. De Maertelaer, O. Alkeilani, S. Sourtzis, and P. A. Gevenois
Suspected Acute Colon Diverticulitis: Imaging with Low-Dose Unenhanced Multi-Detector Row CT
Radiology, October 1, 2005; 237(1): 189 - 196.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. C. O'Daniel, D. M. Stevens, and D. D. Cody
Reducing Radiation Exposure from Survey CT Scans
Am. J. Roentgenol., August 1, 2005; 185(2): 509 - 515.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Das, A. H. Mahnken, G. Muhlenbruch, A. Stargardt, C. Weiss, D.-A. Sennst, T. G. Flohr, R. W. Gunther, and J. E. Wildberger
Individually Adapted Examination Protocols for Reduction of Radiation Exposure for 16-MDCT Chest Examinations
Am. J. Roentgenol., May 1, 2005; 184(5): 1437 - 1443.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, R. V. D'Souza, S. Rizzo, E. F. Halpern, M. A. Blake, and S. Saini
Detection of Urinary Tract Stones at Low-Radiation-Dose CT with Z-Axis Automatic Tube Current Modulation: Phantom and Clinical Studies
Radiology, May 1, 2005; 235(2): 523 - 529.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. A. Leswick, S. T. Webster, B. A. Wilcox, and D. A. Fladeland
Radiation Cost of Helical High-Resolution Chest CT
Am. J. Roentgenol., March 1, 2005; 184(3): 742 - 745.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
S. M. R. Rizzo, M. K. Kalra, M. M. Maher, M. A. Blake, T. L. Toth, and S. Saini
Do Metallic Endoprostheses Increase Radiation Dose Associated with Automatic Tube-Current Modulation in Abdominal-Pelvic MDCT? A Phantom and Patient Study
Am. J. Roentgenol., February 1, 2005; 184(2): 491 - 496.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, R. S. Kamath, T. Horiuchi, T. L. Toth, E. F. Halpern, and S. Saini
Sixteen-Detector Row CT of Abdomen and Pelvis: Study for Optimization of Z-Axis Modulation Technique Performed in 153 Patients
Radiology, October 1, 2004; 233(1): 241 - 249.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J.-F. Paul, H. T. Abada, and A. B. Sigal-Cinqualbre
Automatic Dose Reduction Should Not Mask Needs for Individual Dose Reduction
Radiology, October 1, 2004; 233(1): 297 - 297.
[Full Text] [PDF]


Home page
RadiologyHome page
M. K. Kalra, M. M. Maher, T. L. Toth, R. S. Kamath, E. F. Halpern, and S. Saini
Comparison of Z-Axis Automatic Tube Current Modulation Technique with Fixed Tube Current CT Scanning of Abdomen and Pelvis
Radiology, August 1, 2004; 232(2): 347 - 353.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
T. Beyer, G. Antoch, S. Muller, T. Egelhof, L. S. Freudenberg, J. Debatin, and A. Bockisch
Acquisition Protocol Considerations for Combined PET/CT Imaging
J. Nucl. Med., January 1, 2004; 45(90010): 25S - 35.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Roentgen Ray Society.