OBJECTIVE. Our study evaluated radiologist detection of breast cancer using a computer-aided detection system.
MATERIALS AND METHODS. Three radiologists reviewed 377 screening mammograms interpreted as showing normal or benign findings 9-24 months before cancer diagnosis from 17 of the 18 participating centers. In 313 cases, study radiologists recommended additional mammographic evaluation. In 177 cases, the area warranting additional workup precisely correlated with the subsequently diagnosed cancer. These 177 missed cancers were evaluated with computer-aided detection. The proportion of radiologists identifying the missed cancers was used to determine radiologist sensitivity without computer-aided detection.
RESULTS. The study radiologists determined that 123 of the 377 missed cancer cases warranted workup. Therefore, 123 additional cancers cases could have been found. The calculated radiologist sensitivity without computer-aided detection was therefore 75.4% (377 / [377 + 123]). Similarly, using the performance of the system on the missed cancers, we estimated that 80 (65.0%) of these 123 missed cancer cases would have been identified with the use of computer-aided detection. Consequently, the estimated sensitivity of radiologists using computer-aided detection was 91.4% ([377 + 80] / [377 + 123])resulting in a 21.2% ([91.4% / 75.4%] - 1) increase in radiologist sensitivity with computer-aided detection.
CONCLUSION. Use of the computer-aided detection system significantly improved the detection of breast cancer by increasing radiologist sensitivity by 21.2%. Therefore, for every 100,000 women with breast cancer identified without the use of computer-aided detection, an estimated additional 21,200 cancers would be found with the use of computer-aided detection.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
M. Gromet Comparison of Computer-Aided Detection to Double Reading of Screening Mammograms: Review of 231,221 Mammograms Am. J. Roentgenol., April 1, 2008; 190(4): 854 - 859. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. F. Brem Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography: The Importance of the Question and the Critical Numbers Game Am. J. Roentgenol., November 1, 2007; 189(5): 1142 - 1144. [Full Text] [PDF] |
||||
![]() |
S. K. Yang, W. K. Moon, N. Cho, J. S. Park, J. H. Cha, S. M. Kim, S. J. Kim, and J.-G. Im Screening Mammography-detected Cancers: Sensitivity of a Computer-aided Detection System Applied to Full-Field Digital Mammograms Radiology, July 1, 2007; 244(1): 104 - 111. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Fenton, S. H. Taplin, P. A. Carney, L. Abraham, E. A. Sickles, C. D'Orsi, E. A. Berns, G. Cutter, R. E. Hendrick, W. E. Barlow, et al. Influence of Computer-Aided Detection on Performance of Screening Mammography N. Engl. J. Med., April 5, 2007; 356(14): 1399 - 1409. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Ko, M. J. Nicholas, J. B. Mendel, and P. J. Slanetz Prospective assessment of computer-aided detection in interpretation of screening mammography. Am. J. Roentgenol., December 1, 2006; 187(6): 1483 - 1491. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. R. Pai, N. E. Gregory, A. E. Swinford, and M. Rebner Ductal Carcinoma in Situ: Computer-aided Detection in Screening Mammography Radiology, December 1, 2006; 241(3): 689 - 694. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. J. Gilbert, S. M. Astley, M. A. McGee, M. G. C. Gillan, C. R. M. Boggis, P. M. Griffiths, and S. W. Duffy Single Reading with Computer-aided Detection and Double Reading of Screening Mammograms in the United Kingdom National Breast Screening Program Radiology, October 1, 2006; 241(1): 47 - 53. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Dean and C. C. Ilvento Improved cancer detection using computer-aided detection with diagnostic and screening mammography: prospective study of 104 cancers. Am. J. Roentgenol., July 1, 2006; 187(1): 20 - 28. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. K. Lindfors, M. C. McGahan, C. J. Rosenquist, and G. S. Hurlock Computer-aided Detection of Breast Cancer: A Cost-effectiveness Study Radiology, June 1, 2006; 239(3): 710 - 717. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Morton, D. H. Whaley, K. R. Brandt, and K. K. Amrami Screening Mammograms: Interpretation with Computer-aided Detection--Prospective Evaluation Radiology, May 1, 2006; 239(2): 375 - 383. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Greenberg An Appellate Court Ruling and Potential Implications for CAD Technology in the Courtroom Am. J. Roentgenol., January 1, 2006; 186(1): 52 - 53. [Full Text] [PDF] |
||||
![]() |
L. A. L. Khoo, P. Taylor, and R. M. Given-Wilson Computer-aided Detection in the United Kingdom National Breast Screening Programme: Prospective Study Radiology, November 1, 2005; 237(2): 444 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Baker, E. L. Rosen, M. M. Crockett, and J. Y. Lo Accuracy of Segmentation of a Commercial Computer-aided Detection System for Mammography Radiology, May 1, 2005; 235(2): 385 - 390. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. F. Brem, J. W. Hoffmeister, G. Zisman, M. P. DeSimio, and S. K. Rogers A Computer-Aided Detection System for the Evaluation of Breast Cancer by Mammographic Appearance and Lesion Size Am. J. Roentgenol., March 1, 2005; 184(3): 893 - 896. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. F. Brem, J. W. Hoffmeister, J. A. Rapelyea, G. Zisman, K. Mohtashemi, G. Jindal, M. P. DiSimio, and S. K. Rogers Impact of Breast Density on Computer-Aided Detection for Breast Cancer Am. J. Roentgenol., February 1, 2005; 184(2): 439 - 444. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Doi Current status and future potential of computer-aided diagnosis in medical imaging Br. J. Radiol., January 1, 2005; 78(suppl_1): S3 - s19. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Taylor and R M Given-Wilson Evaluation of computer-aided detection (CAD) devices Br. J. Radiol., January 1, 2005; 78(suppl_1): S26 - S30. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Gur, J. S. Stalder, L. A. Hardesty, B. Zheng, J. H. Sumkin, D. M. Chough, B. E. Shindel, and H. E. Rockette Computer-aided Detection Performance in Mammographic Examination of Masses: Assessment Radiology, November 1, 2004; 233(2): 418 - 423. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. M. Hall and R. F. Brem Improved Sensitivity of Mammography with Computer-Aided Detection Am. J. Roentgenol., June 1, 2004; 182(6): 1598 - 1599. [Full Text] [PDF] |
||||
![]() |
M. A. Guenin and R. F. Brem How Not to Assess Computer-Aided Detection for Mammography Am. J. Roentgenol., June 1, 2004; 182(6): 1599 - 1600. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |