AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yetter, E. M.
Right arrow Articles by Blundell, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yetter, E. M.
Right arrow Articles by Blundell, K.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2003; 181:1615-1620
© American Roentgen Ray Society


Estimating Splenic Volume: Sonographic Measurements Correlated with Helical CT Determination

Ellen M. Yetter 1,2, Katrina B. Acosta1, Mary C. Olson1 and Kenneth Blundell3

1 Department of Radiology, Loyola University Medical Center, Maywood, IL 60153.
2 Present address: Department of Radiology, St. Luke's Hospital of Kansas City, 4401 Wornall Rd., Kansas City, MO 64111.
3 School of Interdisciplinary Computing and Engineering, University of Missouri–Kansas City, Kansas City, MO 64113.

OBJECTIVE. The purpose of this study was to determine which sonographic measurements of the spleen most closely correlate with splenic volume as determined on helical CT.

MATERIALS AND METHODS. From October 17, 2000, to April 27, 2001, 142 consecutive patients prospectively underwent abdominal helical CT and sonography as part of an evaluation for liver disease. Calculations of splenic volumes were based on 10-mm unenhanced images. Maximum length (ML) and width (W), thickness (T), and craniocaudal length (CCL) were measured sonographically. Standard ellipsoid volume formulas (with the addition of new ellipsoid coefficients) and linear regression formulas were calculated for 117 patients whose examinations were performed within 30 days of each other. Mean percent differences, standard deviations, and 95% confidence intervals (CI) were calculated.

RESULTS. We calculated the average difference between sonography- and CT-measured volume and the 95% CI for each of the four initial sonographic volume estimates with the ellipsoid method using two lengths and linear regression using two lengths and compared them to CT-determined volume. The ellipsoid formulas were then adjusted for bias. Linear regression formulas were derived in which splenic volumes were separately calculated on the basis of each of the two lengths. Mean percent differences and standard deviations for ellipsoid formulas with varying coefficients using the three length measurements were also calculated.

CONCLUSION. Sonographic measurements allow accurate determination of splenic volume. Estimating splenic volume with the formula 0.524 x W x T x (ML + CCL) / 2 provides the greatest overall accuracy.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
A. R. Rasekhi, M. Naderifar, M. H. Bagheri, M. Shahriari, H. Foroutan, M. Karimi, and S. A. Nabavizadeh
Radiofrequency Ablation of the Spleen in Patients with Thalassemia Intermedia: A Pilot Study
Am. J. Roentgenol., May 1, 2009; 192(5): 1425 - 1429.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. S. Bezerra, G. D'Ippolito, S. Faintuch, J. Szejnfeld, and M. Ahmed
Determination of Splenomegaly by CT: Is There a Place for a Single Measurement?
Am. J. Roentgenol., May 1, 2005; 184(5): 1510 - 1513.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
A. L. Spielmann, D. M. DeLong, and M. A. Kliewer
Sonographic Evaluation of Spleen Size in Tall Healthy Athletes
Am. J. Roentgenol., January 1, 2005; 184(1): 45 - 49.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS