AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Margolin, F. R.
Right arrow Articles by Schrumpf, J. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Margolin, F. R.
Right arrow Articles by Schrumpf, J. D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2003; 181:1685-1690
© American Roentgen Ray Society


Metallic Marker Placement After Stereotactic Core Biopsy of Breast Calcifications: Comparison of Two Clips and Deployment Techniques

Frederick R. Margolin1, Lauren Kaufman, Susan R. Denny, Richard P. Jacobs and John D. Schrumpf

1 All authors: Breast Health Center, California Pacific Medical Center, 3698 California St., San Francisco, CA 94118.

OBJECTIVE. Two methods of deployment of metallic clips at the site of stereotactic core biopsy for breast calcifications are compared retrospectively.

MATERIALS AND METHODS. One hundred nineteen clips deployed through an 11-gauge vacuum-assisted biopsy probe at core biopsy sites were compared with 109 vascular ligating clips deployed at biopsy sites using an 18-gauge spinal needle. The distance of each clip from the position of the target calcification was assessed using stereotactic coordinates in 52 sequential cases and was measured on mammograms before and after biopsy in 108 clips deployed through an 11-gauge probe and 98 clips deployed using an 18-gauge needle. Variance in clip position between postbiopsy and follow-up mammograms was measured in 43 clips placed with an 11-gauge probe and in 44 clips placed with an 18-gauge needle. Comparable measurements of variance in position of fat necrosis calcifications between screening mammograms were used as controls.

RESULTS. Ninety-seven percent of the clips placed with an 11-gauge probe and 98% of the clips placed using an 18-gauge needle were within 1 cm of the target calcifications using stereotactic coordinates. On mammograms obtained after biopsy, 70% of the clips placed with an 11-gauge probe and 63% of the clips placed using an 18-gauge needle were within 1 cm of the target calcifications, and the position of 91% of the clips placed with an 11-gauge probe and 90% of the clips placed using an 18-gauge needle varied less than 15 mm on follow-up mammograms. Both clips provided accurate targets for wire-localized excisions. The cost of the 11-gauge needle and clip is $320. The 14-gauge probe, vascular clip, and 18-gauge spinal needle cost $191.58.

CONCLUSION. A vascular ligating clip delivered to a stereotactic core biopsy site by an 18-gauge spinal needle is comparable in apparent accuracy and stability to a clip deployed through an 11-gauge probe. This technique allows core biopsies to be performed with instruments smaller than 11-gauge and at a 40% savings in equipment cost.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
K. Calhoun, A. Giuliano, and R. J. Brenner
Intraoperative Loss of Core Biopsy Clips: Clinical Implications
Am. J. Roentgenol., March 1, 2008; 190(3): W196 - W200.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. R. Margolin, L. Kaufman, R. P. Jacobs, S. R. Denny, and J. D. Schrumpf
Stereotactic Core Breast Biopsy of Malignant Calcifications: Diagnostic Yield of Cores with and Cores without Calcifications on Specimen Radiographs
Radiology, October 1, 2004; 233(1): 251 - 254.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2003 by the American Roentgen Ray Society.