AJR InPractice
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taouli, B.
Right arrow Articles by Coakley, F. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Taouli, B.
Right arrow Articles by Coakley, F. V.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2004; 183:677-680
© American Roentgen Ray Society


Abdominal Imaging

Parallel Imaging and Diffusion Tensor Imaging for Diffusion-Weighted MRI of the Liver: Preliminary Experience in Healthy Volunteers

Bachir Taouli1,2, Alastair J. Martin1, Aliya Qayyum1, Raphael B. Merriman3, Daniel Vigneron1, Benjamin M. Yeh1 and Fergus V. Coakley1

1 Department of Radiology, University of California, San Francisco, 505 Parnassus Ave., San Francisco, CA 94143.
2 Department of Radiology, New York University Medical Center, 560 First Ave., TCH–HW 202, New York, NY 10016.
3 Department of Medicine, Division of Gastroenterology, University of California, San Francisco, San Francisco, CA 94143.

Abstract

OBJECTIVE. Our aim was to determine whether parallel imaging and diffusion tensor imaging affect the measurement of apparent diffusion coefficient (ADC) during diffusion-weighted MRI of the liver in healthy volunteers.

SUBJECTS AND METHODS. We performed breath-hold single-shot echo-planar diffusion-weighted MRI of the liver in 10 healthy volunteers using conventional diffusion, conventional diffusion with parallel imaging, and diffusion tensor with parallel imaging sequences. TE values for the three sequences were 83, 74, and 63, respectively. Liver signal intensity was measured on all sequences and normalized to the SD of the measurement. Hepatic ADC was calculated by acquiring all sequences with b values of 0 and 500 sec/mm2.

RESULTS. The normalized liver signal intensity was higher on diffusion tensor with parallel imaging and conventional diffusion with parallel imaging than on conventional diffusion without parallel imaging for a b value of 500 sec/mm2 (13.0 and 10.1 vs 9.1, respectively; p < 0.03) and for a b value of 0 sec/mm2 (9.0 and 7.6 vs 6.9, respectively; without reaching a significant difference, p = 0.12). Hepatic ADC was not significantly different between sequences (p = 0.16).

CONCLUSION. Higher signal intensity can be obtained when using parallel imaging and diffusion tensor imaging during diffusion-weighted MRI of the liver without compromising hepatic ADC measurement.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
L. Mannelli, S. Kim, C. H. Hajdu, J. S. Babb, T. W. I. Clark, and B. Taouli
Assessment of Tumor Necrosis of Hepatocellular Carcinoma After Chemoembolization: Diffusion-Weighted and Contrast-Enhanced MRI With Histopathologic Correlation of the Explanted Liver
Am. J. Roentgenol., October 1, 2009; 193(4): 1044 - 1052.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
S. C. Faria, K. Ganesan, I. Mwangi, M. Shiehmorteza, B. Viamonte, S. Mazhar, M. Peterson, Y. Kono, C. Santillan, G. Casola, et al.
MR Imaging of Liver Fibrosis: Current State of the Art
RadioGraphics, October 1, 2009; 29(6): 1615 - 1635.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
F. Saremi, A. N. Knoll, O. J. Bendavid, H. Schultze-Haakh, N. Narula, and F. Sarlati
Characterization of Genitourinary Lesions with Diffusion-weighted Imaging
RadioGraphics, September 1, 2009; 29(5): 1295 - 1317.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
R. N. Low, C. P. Sebrechts, R. M. Barone, and W. Muller
Diffusion-Weighted MRI of Peritoneal Tumors: Comparison With Conventional MRI and Surgical and Histopathologic Findings--A Feasibility Study
Am. J. Roentgenol., August 1, 2009; 193(2): 461 - 470.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Taouli, R. L. Ehman, and S. B. Reeder
Advanced MRI Methods for Assessment of Chronic Liver Disease
Am. J. Roentgenol., July 1, 2009; 193(1): 14 - 27.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Kandpal, R. Sharma, K. S. Madhusudhan, and K. S. Kapoor
Respiratory-Triggered Versus Breath-Hold Diffusion-Weighted MRI of Liver Lesions: Comparison of Image Quality and Apparent Diffusion Coefficient Values
Am. J. Roentgenol., April 1, 2009; 192(4): 915 - 922.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. C. Braithwaite, B. M. Dale, D. T. Boll, and E. M. Merkle
Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen
Radiology, February 1, 2009; 250(2): 459 - 465.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
T NIWA, M UENO, S OHKAWA, T YOSHIDA, T DOIUCHI, K ITO, and T INOUE
Advanced pancreatic cancer: the use of the apparent diffusion coefficient to predict response to chemotherapy
Br. J. Radiol., January 1, 2009; 82(973): 28 - 34.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
A. Luciani, A. Vignaud, M. Cavet, J. Tran Van Nhieu, A. Mallat, L. Ruel, A. Laurent, J.-F. Deux, P. Brugieres, and A. Rahmouni
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging--Pilot Study
Radiology, December 1, 2008; 249(3): 891 - 899.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. Bruegel, J. Gaa, S. Waldt, K. Woertler, K. Holzapfel, B. Kiefer, and E. J. Rummeny
Diagnosis of Hepatic Metastasis: Comparison of Respiration-Triggered Diffusion-Weighted Echo-Planar MRI and Five T2-Weighted Turbo Spin-Echo Sequences
Am. J. Roentgenol., November 1, 2008; 191(5): 1421 - 1429.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
T. Parikh, S. J. Drew, V. S. Lee, S. Wong, E. M. Hecht, J. S. Babb, and B. Taouli
Focal Liver Lesion Detection and Characterization with Diffusion-weighted MR Imaging: Comparison with Standard Breath-hold T2-weighted Imaging
Radiology, March 1, 2008; 246(3): 812 - 822.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
B. Taouli, A. J. Tolia, M. Losada, J. S. Babb, E. S. Chan, M. A. Bannan, and H. Tobias
Diffusion-Weighted MRI for Quantification of Liver Fibrosis: Preliminary Experience
Am. J. Roentgenol., October 1, 2007; 189(4): 799 - 806.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
K Coenegrachts, J Delanote, L Ter Beek, M Haspeslagh, S Bipat, J Stoker, F Van Kerkhove, L Steyaert, H Rigauts, and J W Casselman
Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques
Br. J. Radiol., July 1, 2007; 80(955): 524 - 531.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D.-M. Koh and D. J. Collins
Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology
Am. J. Roentgenol., June 1, 2007; 188(6): 1622 - 1635.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D.-M. Koh, E. Scurr, D. Collins, B. Kanber, A. Norman, M. O. Leach, and J. E. Husband
Predicting Response of Colorectal Hepatic Metastasis: Value of Pretreatment Apparent Diffusion Coefficients
Am. J. Roentgenol., April 1, 2007; 188(4): 1001 - 1008.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
T. Yoshikawa, H. Kawamitsu, D. G. Mitchell, Y. Ohno, Y. Ku, Y. Seo, M. Fujii, and K. Sugimura
ADC measurement of abdominal organs and lesions using parallel imaging technique.
Am. J. Roentgenol., December 1, 2006; 187(6): 1521 - 1530.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
V Vandecaveye, F de Keyzer, V Vander Poorten, K Deraedt, H Alaerts, W Landuyt, S Nuyts, and R Hermans
Evaluation of the larynx for tumour recurrence by diffusion-weighted MRI after radiotherapy: initial experience in four cases
Br. J. Radiol., August 1, 2006; 79(944): 681 - 687.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
V. S. Lee
Science to Practice: Can MR Imaging Replace Liver Biopsy for the Diagnosis of Early Fibrosis?
Radiology, May 1, 2006; 239(2): 309 - 310.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
F. Chen, X. Sun, F. De Keyzer, J. Yu, R. Peeters, W. Coudyzer, V. Vandecaveye, W. Landuyt, H. Bosmans, P. Van Hecke, et al.
Liver Tumor Model with Implanted Rhabdomyosarcoma in Rats: MR Imaging, Microangiography, and Histopathologic Analysis
Radiology, May 1, 2006; 239(2): 554 - 562.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.