Abdominal Imaging |
1 Department of Radiology, University of California, San Francisco, 505
Parnassus Ave., San Francisco, CA 94143.
2 Department of Radiology, New York University Medical Center, 560 First Ave.,
TCHHW 202, New York, NY 10016.
3 Department of Medicine, Division of Gastroenterology, University of
California, San Francisco, San Francisco, CA 94143.
Abstract
OBJECTIVE. Our aim was to determine whether parallel imaging and diffusion tensor imaging affect the measurement of apparent diffusion coefficient (ADC) during diffusion-weighted MRI of the liver in healthy volunteers.
SUBJECTS AND METHODS. We performed breath-hold single-shot echo-planar diffusion-weighted MRI of the liver in 10 healthy volunteers using conventional diffusion, conventional diffusion with parallel imaging, and diffusion tensor with parallel imaging sequences. TE values for the three sequences were 83, 74, and 63, respectively. Liver signal intensity was measured on all sequences and normalized to the SD of the measurement. Hepatic ADC was calculated by acquiring all sequences with b values of 0 and 500 sec/mm2.
RESULTS. The normalized liver signal intensity was higher on diffusion tensor with parallel imaging and conventional diffusion with parallel imaging than on conventional diffusion without parallel imaging for a b value of 500 sec/mm2 (13.0 and 10.1 vs 9.1, respectively; p < 0.03) and for a b value of 0 sec/mm2 (9.0 and 7.6 vs 6.9, respectively; without reaching a significant difference, p = 0.12). Hepatic ADC was not significantly different between sequences (p = 0.16).
CONCLUSION. Higher signal intensity can be obtained when using parallel imaging and diffusion tensor imaging during diffusion-weighted MRI of the liver without compromising hepatic ADC measurement.
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
![]() |
L. Mannelli, S. Kim, C. H. Hajdu, J. S. Babb, T. W. I. Clark, and B. Taouli Assessment of Tumor Necrosis of Hepatocellular Carcinoma After Chemoembolization: Diffusion-Weighted and Contrast-Enhanced MRI With Histopathologic Correlation of the Explanted Liver Am. J. Roentgenol., October 1, 2009; 193(4): 1044 - 1052. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Faria, K. Ganesan, I. Mwangi, M. Shiehmorteza, B. Viamonte, S. Mazhar, M. Peterson, Y. Kono, C. Santillan, G. Casola, et al. MR Imaging of Liver Fibrosis: Current State of the Art RadioGraphics, October 1, 2009; 29(6): 1615 - 1635. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Saremi, A. N. Knoll, O. J. Bendavid, H. Schultze-Haakh, N. Narula, and F. Sarlati Characterization of Genitourinary Lesions with Diffusion-weighted Imaging RadioGraphics, September 1, 2009; 29(5): 1295 - 1317. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. N. Low, C. P. Sebrechts, R. M. Barone, and W. Muller Diffusion-Weighted MRI of Peritoneal Tumors: Comparison With Conventional MRI and Surgical and Histopathologic Findings--A Feasibility Study Am. J. Roentgenol., August 1, 2009; 193(2): 461 - 470. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Taouli, R. L. Ehman, and S. B. Reeder Advanced MRI Methods for Assessment of Chronic Liver Disease Am. J. Roentgenol., July 1, 2009; 193(1): 14 - 27. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kandpal, R. Sharma, K. S. Madhusudhan, and K. S. Kapoor Respiratory-Triggered Versus Breath-Hold Diffusion-Weighted MRI of Liver Lesions: Comparison of Image Quality and Apparent Diffusion Coefficient Values Am. J. Roentgenol., April 1, 2009; 192(4): 915 - 922. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. C. Braithwaite, B. M. Dale, D. T. Boll, and E. M. Merkle Short- and Midterm Reproducibility of Apparent Diffusion Coefficient Measurements at 3.0-T Diffusion-weighted Imaging of the Abdomen Radiology, February 1, 2009; 250(2): 459 - 465. [Abstract] [Full Text] [PDF] |
||||
![]() |
T NIWA, M UENO, S OHKAWA, T YOSHIDA, T DOIUCHI, K ITO, and T INOUE Advanced pancreatic cancer: the use of the apparent diffusion coefficient to predict response to chemotherapy Br. J. Radiol., January 1, 2009; 82(973): 28 - 34. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Luciani, A. Vignaud, M. Cavet, J. Tran Van Nhieu, A. Mallat, L. Ruel, A. Laurent, J.-F. Deux, P. Brugieres, and A. Rahmouni Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging--Pilot Study Radiology, December 1, 2008; 249(3): 891 - 899. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Bruegel, J. Gaa, S. Waldt, K. Woertler, K. Holzapfel, B. Kiefer, and E. J. Rummeny Diagnosis of Hepatic Metastasis: Comparison of Respiration-Triggered Diffusion-Weighted Echo-Planar MRI and Five T2-Weighted Turbo Spin-Echo Sequences Am. J. Roentgenol., November 1, 2008; 191(5): 1421 - 1429. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Parikh, S. J. Drew, V. S. Lee, S. Wong, E. M. Hecht, J. S. Babb, and B. Taouli Focal Liver Lesion Detection and Characterization with Diffusion-weighted MR Imaging: Comparison with Standard Breath-hold T2-weighted Imaging Radiology, March 1, 2008; 246(3): 812 - 822. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Taouli, A. J. Tolia, M. Losada, J. S. Babb, E. S. Chan, M. A. Bannan, and H. Tobias Diffusion-Weighted MRI for Quantification of Liver Fibrosis: Preliminary Experience Am. J. Roentgenol., October 1, 2007; 189(4): 799 - 806. [Abstract] [Full Text] [PDF] |
||||
![]() |
K Coenegrachts, J Delanote, L Ter Beek, M Haspeslagh, S Bipat, J Stoker, F Van Kerkhove, L Steyaert, H Rigauts, and J W Casselman Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T2 weighted turbo spin echo techniques Br. J. Radiol., July 1, 2007; 80(955): 524 - 531. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.-M. Koh and D. J. Collins Diffusion-Weighted MRI in the Body: Applications and Challenges in Oncology Am. J. Roentgenol., June 1, 2007; 188(6): 1622 - 1635. [Abstract] [Full Text] [PDF] |
||||
![]() |
D.-M. Koh, E. Scurr, D. Collins, B. Kanber, A. Norman, M. O. Leach, and J. E. Husband Predicting Response of Colorectal Hepatic Metastasis: Value of Pretreatment Apparent Diffusion Coefficients Am. J. Roentgenol., April 1, 2007; 188(4): 1001 - 1008. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yoshikawa, H. Kawamitsu, D. G. Mitchell, Y. Ohno, Y. Ku, Y. Seo, M. Fujii, and K. Sugimura ADC measurement of abdominal organs and lesions using parallel imaging technique. Am. J. Roentgenol., December 1, 2006; 187(6): 1521 - 1530. [Abstract] [Full Text] [PDF] |
||||
![]() |
V Vandecaveye, F de Keyzer, V Vander Poorten, K Deraedt, H Alaerts, W Landuyt, S Nuyts, and R Hermans Evaluation of the larynx for tumour recurrence by diffusion-weighted MRI after radiotherapy: initial experience in four cases Br. J. Radiol., August 1, 2006; 79(944): 681 - 687. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Lee Science to Practice: Can MR Imaging Replace Liver Biopsy for the Diagnosis of Early Fibrosis? Radiology, May 1, 2006; 239(2): 309 - 310. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Chen, X. Sun, F. De Keyzer, J. Yu, R. Peeters, W. Coudyzer, V. Vandecaveye, W. Landuyt, H. Bosmans, P. Van Hecke, et al. Liver Tumor Model with Implanted Rhabdomyosarcoma in Rats: MR Imaging, Microangiography, and Histopathologic Analysis Radiology, May 1, 2006; 239(2): 554 - 562. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |