AJR AJR-based Continuing Ed for Technologists
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dachman, A. H.
Right arrow Articles by LaRiviere, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dachman, A. H.
Right arrow Articles by LaRiviere, P.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2004; 183:1349-1353
© American Roentgen Ray Society

The Effect of Reconstruction Algorithm on Conspicuity of Polyps in CT Colonography

Abraham H. Dachman1, Phil Schumm2, Beth Heckel3, Hiroyuki Yoshida1 and Patrick LaRiviere1

1 Department of Radiology, MC 2026, University of Chicago, 5841 S Maryland Ave., Chicago, IL 60637.
2 Department of Health Studies, University of Chicago, Chicago, IL 60637.
3 GE Healthcare, Chicago, IL 60605.

OBJECTIVE. CT colonography studies to date have used a standard CT algorithm. To determine whether nonstandard algorithms may result in better performance of CT colonography, we conducted a prospective, blinded-observer study of the effect of the reconstruction algorithm on the conspicuity of colonic polyps and folds.

SUBJECTS AND METHODS. CT colonography of patients with proven polyps, masses, or polypoid folds was performed on an MDCT scanner, and the images were reconstructed using the standard, soft, lung, and detail algorithms. Two experiments were performed. The first used four patient data sets of a short segment of colon (30-60 images), each reconstructed using all four algorithms and then viewed on a workstation in a four-on-one format that allowed all four reconstructions to be viewed simultaneously. The second used six sets of cut-film images (four or eight images each); images within each set differed only in the reconstruction algorithm used to generate them (eight-image sets were prepared with two different level settings). Twenty-one reviewers with varying levels of experience who were unaware of the purpose of the study were asked to rank the images within each set according to their value in the detection of either polyps or masses.

RESULTS. Reviewers showed statistically significant differences in preference for the four algorithms (p = 0.037 in the computer-based experiment; for the cut-film experiment, p = 0.029 for the four-image sets and p = 0.041 for the eight-image sets). In the computer-based experiment, reviewers preferred the detail algorithm to the standard algorithm with an estimated probability of 0.67 (95% confidence interval [CI], 0.57-0.75) and the soft algorithm over the standard algorithm with an estimated probability of 0.59 (95% CI, 0.51-0.66). However, reviewers with the most experience (having interpreted at least 250 cases) preferred the soft algorithm over the standard algorithm by the same two-to-one margin as observed for the detail algorithm. In contrast, the standard and detail algorithms were ranked similarly in the cut-film experiment, with the soft and lung algorithms ranked worst.

CONCLUSION. To our knowledge, ours is the first observer study on the effect of the reconstruction algorithm on conspicuity of folds and polyps in CT colonography. Our results indicate significant differences in the reconstruction algorithms, with the soft and detail algorithms being preferred over the standard algorithm by experienced reviewers when interpreting images on a workstation. These results indicate the need for further research into the effect of reconstruction algorithms on CT colonography.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadioGraphicsHome page
T. Mang, A. Maier, C. Plank, C. Mueller-Mang, C. Herold, and W. Schima
Pitfalls in Multi-Detector Row CT Colonography: A Systematic Approach
RadioGraphics, March 1, 2007; 27(2): 431 - 454.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
S. A. Taylor, S. Halligan, A. Slater, V. Goh, D. N. Burling, M. E. Roddie, L. Honeyfield, J. McQuillan, H. Amin, and J. Dehmeshki
Polyp Detection with CT Colonography: Primary 3D Endoluminal Analysis versus Primary 2D Transverse Analysis with Computer-assisted Reader Software
Radiology, June 1, 2006; 239(3): 759 - 767.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.