AJR ARRS Membership
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sanelli, P. C.
Right arrow Articles by Heier, L. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sanelli, P. C.
Right arrow Articles by Heier, L. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
AJR 2004; 183:1829-1834
© American Roentgen Ray Society

Safety and Feasibility of Using a Central Venous Catheter for Rapid Contrast Injection Rates

Pina C. Sanelli1, Monica Deshmukh2, Igor Ougorets3, Rachael Caiati1 and Linda A. Heier1

1 Department of Radiology, New York Presbyterian Hospital, Weill Medical College of Cornell University, 520 E 70th St., Starr Pavilion–630, New York, NY 10021.
2 University of Medicine and Dentistry of New Jersey, Robert Wood Johnson Medical School, 401 Haddon Ave., Camden, NJ 08103.
3 Department of Neurology, New York Presbyterian Hospital, Weill Medical College of Cornell University, New York, NY 10021.

OBJECTIVE. Our aim was to determine the safety and feasibility of using a central venous catheter for rapid contrast injections during CT.

MATERIALS AND METHODS. An in vitro experiment was performed using a 7-French Arrow-Howes multilumen central venous catheter. Each catheter port was tested by varying contrast agent flow rates delivered by a power injector. Contrast media specifications were kept similar to routine clinical practice. The in vivo experiment included 104 cases in which rapid contrast injections, 3.0–5.0 mL/sec, were delivered through a central venous catheter for dynamic CT examinations. Patient monitoring for early complications of contrast extravasation, cardiac arrhythmia, and allergic reactions was performed. Contrast injections were monitored for pressure limitation, automatic flow-rate adjustment, and catheter injury. Chart review was performed for delayed complications of mediastinal hematoma, infection, or catheter malfunction.

RESULTS. During the in vitro experiment, all desired flow rates, 3.0–9.9 mL/sec, could be delivered through the central venous catheter with no catheter injury. No immediate or early patient or catheter complications were observed during the in vivo experiment. Follow-up evaluation revealed that 18 blood cultures and one catheter culture were positive for bacterial growth. In a subgroup of 43 patients, five contrast injections were pressure-limited by the power injector, and only one had the flow rate automatically adjusted to 3.6 mL/sec from 4.0 mL/sec.

CONCLUSION. Rapid contrast injection rates, at 3.0–5.0 mL/sec, through the Arrow-Howes multilumen central venous catheter are feasible and safe in the clinical setting. However, a strict protocol should be followed to avoid possible serious complications.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
L. F. Donnelly, J. Dickerson, and J. M. Racadio
Is Hand Injection of Central Venous Catheters for Contrast-Enhanced CT Safe in Children?
Am. J. Roentgenol., December 1, 2007; 189(6): 1530 - 1532.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Neuroradiol.Home page
P.C. Sanelli, G. Nicola, R. Johnson, A.J. Tsiouris, I. Ougorets, C. Knight, B. Frommer, S. Veronelli, and R.D. Zimmerman
Effect of Training and Experience on Qualitative and Quantitative CT Perfusion Data
AJNR Am. J. Neuroradiol., March 1, 2007; 28(3): 428 - 432.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
C. K. Rigsby, E. Gasber, R. Seshadri, C. Sullivan, M. Wyers, and T. Ben-Ami
Safety and Efficacy of Pressure-Limited Power Injection of Iodinated Contrast Medium Through Central Lines in Children
Am. J. Roentgenol., March 1, 2007; 188(3): 726 - 732.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
P. C. Sanelli, G. Nicola, A. J. Tsiouris, I. Ougorets, C. Knight, B. Frommer, S. Veronelli, and R. D. Zimmerman
Reproducibility of Postprocessing of Quantitative CT Perfusion Maps
Am. J. Roentgenol., January 1, 2007; 188(1): 213 - 218.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
P O'Sullivan, M Brown, B Hartnett, and J R Mayo
Central line pump infusion and large volume mediastinal contrast extravasation in CT
Br. J. Radiol., August 1, 2006; 79(944): e75 - e77.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2004 by the American Roentgen Ray Society.