AJR ARRS PQI
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Soo, M. S.
Right arrow Articles by Baker, J. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Soo, M. S.
Right arrow Articles by Baker, J. A.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Hotlight (NEW!)
Right arrow
What's Hotlight?
AJR 2005; 184:887-892
© American Roentgen Ray Society

Computer-Aided Detection of Amorphous Calcifications

Mary Scott Soo1, Eric L. Rosen1, Jessie Q. Xia1, Sujata Ghate1 and Jay A. Baker1

1 All authors: Department of Radiology, Duke University Medical Center, Box 3808, DUMC, 2nd Fl., Red Zone, South Hospital, Durham, NC 27710.

OBJECTIVE. Computer-aided detection (CAD) systems have been used successfully to detect malignant calcifications on mammography, with sensitivities ranging from 86% to 99%. Amorphous calcifications are a subset of small indistinct calcifications of intermediate concern that have a 20% likelihood of being malignant and that are frequently overlooked on mammography. The purpose of our study was to determine the sensitivity of one commercially available CAD system for detecting amorphous calcifications.

MATERIALS AND METHODS. A commercially available CAD system evaluated mammograms of 82 patients with 85 mammographically detected and histologically sampled groups of amorphous calcifications (21 malignant, 14 high risk, and 50 benign). The sensitivity of the system for detecting the calcifications on at least one image of the two-view mammographic examination (case sensitivity) and on each individual mammographic image (image sensitivity) was determined. Findings were correlated with results from large core needle biopsy or surgical excision in each case.

RESULTS. The CAD system detected amorphous calcifications in 43 of 85 cases (case sensitivity, 51%) and in 59 of 146 mammographic images (image sensitivity, 40%). The case sensitivities by histologic outcome were 57% for malignant calcifications, 29% for high-risk calcifications, and 54% for benign calcifications. An average of 2.0 false-positive marks were displayed per case.

CONCLUSION. The CAD sensitivity for malignant amorphous calcifications is markedly lower than previously reported for all malignant calcifications. Breast imaging radiologists who use CAD systems should continue to search diligently for these difficult-to-detect lesions.


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
R. L. Birdwell
The Preponderance of Evidence Supports Computer-aided Detection for Screening Mammography
Radiology, October 1, 2009; 253(1): 9 - 16.
[Full Text] [PDF]


Home page
RadiologyHome page
L. E. Philpotts
Can Computer-aided Detection Be Detrimental to Mammographic Interpretation?
Radiology, October 1, 2009; 253(1): 17 - 22.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
D. Georgian-Smith, R. H. Moore, E. Halpern, E. D. Yeh, E. A. Rafferty, H. A. D'Alessandro, M. Staffa, D. A. Hall, K. A. McCarthy, and D. B. Kopans
Blinded Comparison of Computer-Aided Detection with Human Second Reading in Screening Mammography
Am. J. Roentgenol., November 1, 2007; 189(5): 1135 - 1141.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
R. L. Ellis, A. A. Meade, M. A. Mathiason, K. M. Willison, and W. Logan-Young
Evaluation of Computer-aided Detection Systems in the Detection of Small Invasive Breast Carcinoma
Radiology, October 1, 2007; 245(1): 88 - 94.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
J. M. Ko, M. J. Nicholas, J. B. Mendel, and P. J. Slanetz
Prospective assessment of computer-aided detection in interpretation of screening mammography.
Am. J. Roentgenol., December 1, 2006; 187(6): 1483 - 1491.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
F. M. Hall
Computer-Aided Detection (CAD) of Amorphous Calcifications
Am. J. Roentgenol., March 1, 2006; 186(3): 902 - 902.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
M. S. Soo, S. Ghate, J. A. Baker, and E. Rosen
Reply
Am. J. Roentgenol., March 1, 2006; 186(3): 902 - 903.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Roentgen Ray Society.