AJR Women's Imaging Online
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yamamoto, A.
Right arrow Articles by Inoue, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Yamamoto, A.
Right arrow Articles by Inoue, Y.
DOI:10.2214/AJR.04.0968
AJR 2005; 185:1299-1306
© American Roentgen Ray Society


Clinical Observations

Radiofrequency Ablation in a Porcine Lung Model: Correlation Between CT and Histopathologic Findings

Akira Yamamoto1, Kenji Nakamura1, Toshiyuki Matsuoka1, Masami Toyoshima1, Tomohisa Okuma1, Yoshimasa Oyama1, Yoshihiro Ikura2, Makiko Ueda2 and Yuichi Inoue1

1 Department of Radiology, Osaka City University Graduate School of Medicine, 1-4-3 Asahi-machi, Abeno-ku, Osaka 545-8585, Japan.
2 Department of Pathology, Osaka City University Graduate School of Medicine, Abeno-ku, Osaka 545-8585, Japan.

OBJECTIVE. The objective of our study was to investigate the time course changes of the ablated lesion after radiofrequency ablation in the porcine lung and the correlation between CT and histopathologic findings.

CONCLUSION. Ground-glass attenuation on CT led to overestimation of the size of necrotic lesions. The layered structural findings on CT were consistent with the histopathologic findings. Although CT findings reflect the histopathologic findings, attention should be paid to the dissociation of ablated lesions and high-density areas in clinical interpretation of CT images.




This article has been cited by other articles:


Home page
RadiologyHome page
N. A. Durick, P. F. Laeseke, L. S. Broderick, F. T. Lee Jr, L. A. Sampson, T. M. Frey, T. F. Warner, J. P. Fine, D. W. van der Weide, and C. L. Brace
Microwave Ablation with Triaxial Antennas Tuned for Lung: Results in an in Vivo Porcine Model
Radiology, April 1, 2008; 247(1): 80 - 87.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Hiraki, H. Gobara, T. Iishi, Y. Sano, T. Iguchi, H. Fujiwara, N. Tajiri, J. Sakurai, H. Date, H. Mimura, et al.
Percutaneous radiofrequency ablation for clinical stage I non-small cell lung cancer: results in 20 nonsurgical candidates.
J. Thorac. Cardiovasc. Surg., November 1, 2007; 134(5): 1306 - 1312.
[Abstract] [Full Text] [PDF]


Home page
JNMHome page
N. Avril
18F-FDG PET After Radiofrequency Ablation: Is Timing Everything?
J. Nucl. Med., August 1, 2006; 47(8): 1235 - 1237.
[Full Text] [PDF]


Home page
JNMHome page
T. Okuma, T. Matsuoka, T. Okamura, Y. Wada, A. Yamamoto, Y. Oyama, K. Koyama, K. Nakamura, Y. Watanabe, and Y. Inoue
18F-FDG Small-Animal PET for Monitoring the Therapeutic Effect of CT-Guided Radiofrequency Ablation on Implanted VX2 Lung Tumors in Rabbits
J. Nucl. Med., August 1, 2006; 47(8): 1351 - 1358.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2005 by the American Roentgen Ray Society.